Acknowledgement
Supported by : Korea Forest Service
References
- Arbelaiz A., B. Fernandez, J. A. Ramos, and I. Mondragon. 2005. Thermal and crystallization studies of short flax fibre reinforced polypropylene matrix composites: Effect of treatments. Thermochimica Acta 440: 111-121.
- ASTM-D6007-96. 1996. Standard test method for determining formaldehyde concentrations in air from wood products using a small scale chamber.
- CEC-Commission of the European Communities, prENV 13419-2. 1998. Building products-determination of the emission of volatile organic compounds-Part 2: Emission test cell method, Brussels: European Committee for Standardization.
- Demir H., U. Atikler, D. balkose, and F. Tihminlioglu. 2006. The effect of fiber surface treatments on the tensile and water sorption properties of polypropylene-luffa fiber composites. Composites Part A 37: 447-156. https://doi.org/10.1016/j.compositesa.2005.05.036
- ECA-IAQ Report No.16. 1995. Determination of VOCs emitted from indoor materials and products - Second inter laboratory comparison of small chamber measurements, Brussels.
- ENV 13419-1. 1999. Building products-Determination of the emission of volatile organic compounds-Part 1: Emission test chamber method, Brussels, European Committee for Standardization.
- Gustaffson H. 1992. Building materials identified as major emission sources for indoor air pollutants-a critical review of case studies, Document D10 1992 ISBN 91-540-5471-0 Stockholm, Sweden: Swedish Council for Building Research
- ISO 16000-10, 2004. Indoor-Air Part 10: Determination of theemission of volatile organic compounds-Emission test cell method. International Organization for Standardization.
- Kavvouras P. K., D. Koniditsiotis, and J. Satola. 1998. Resistance of cured urea-formaldehyde resins to hydrolysis: a method of evaluation. Holzforschung 52: 105-110. https://doi.org/10.1515/hfsg.1998.52.1.105
- Kim H.-S., H.-S. Yang, H.-J. Kim, B.-J. Lee, and T.-S. Hwang. 2005. Thermal properties of agroflour- filled biodegradable polymer bio-composites. Journal of Thermal Analysis and Calorimetry 81: 299-306. https://doi.org/10.1007/s10973-005-0782-7
- Kim S. and H.-J. Kim. 2005. Comparison of formaldehyde emission from building finishing materials as temperature in under heating system; ONDOL. Indoor Air 15: 317-325. https://doi.org/10.1111/j.1600-0668.2005.00368.x
- Kim S., H.-J. Kim, and S.-J. Moon. 2006a. Evaluation of VOC emissions from building finishing materials using a small chamber and VOC analyser. Indoor and Built Environment 15: 511-523. https://doi.org/10.1177/1420326X06072040
- Kim S., J.-A Kim, H.-J. Kim, and S.-D. Kim. 2006b. Determination of formaldehyde and TVOC emission factor from wood-based composites by small chamber method. Polymer Testing 25: 605-614. https://doi.org/10.1016/j.polymertesting.2006.04.008
- Kim S., J.-A Kim, and H.-J. Kim. 2007. Application of Field and Laboratory Emission Cell (FLEC) to Determine Formaldehyde and VOCs Emissions from Wood-Based Composites. Mokchae Konghak 35: 24-37.
- Uchiyama, S., T. Akimoto, and S.-I. Tanabe. 2001. Emission rate measurement of chemical compounds emitted from the thermal insulating materials, International FLEC Symposium 2001. pp. 110-115.