Abstract
The objective of this paper is to identify the compression forces and inelastic failure mode using stiffened steel plate-concrete structures. The compression tests were carried out for the three types of B/t ratios by 25, 33 and 50. The test results proved that the compressive strength of the stiffened SC structures can be estimated by the summation of the strengths both stiffened steel plate and concrete. The buckling of the steel plates had been occurred at the plates between studs. The empirical estimation of compressive strength for the stiffened SC structures under compressive loadings was suggested. The buckling behavior also compared with the results of the finite element analysis. The good agreement has been achieved between the experimental results and finite element results.
본 연구는 보강 강판-콘크리트로 이루어진 구조의 압축실험을 통해 압축강도 및 비탄성 파괴모드를 파악하기 위한 것이 주목적이다. 강판두께(t)에 대한 스터드 간격(B)비를 세가지(25, 33, 50)로 분류하여 압축강도 실험을 실시하였다. 실험을 통해서 보강 강판-콘크리트 구조의 압축강도는 콘크리트와 강판의 누가방식으로 예측하는 것이 타당하다고 판단되었다. 강판의 좌굴은 스터드와 스터드 사이의 취약한 부분에서 비탄성국부좌굴이 발생하였다. 그리고 압축하중 지배하의 보강 SC 구조물에 대한 압축강도의 경험적 계산치를 제시하였다. 좌굴 거동을 유한요소해석 결과와 비교하였으며 비교결과 실제 시험체의 좌굴거동과 유한요소해석 결과와 유사한 것으로 나타났다.