Abstract
In this study, cyclic tests of beam-column connections composed with members applicable to the domestic low-middle rise steel buildings were conducted to develop seismic connection details and its evaluation. Connection types and material properties of the steel were testing variables and the difference between the newly developed seismic rolled section (SHN490) and existing rolled section (SM490) was also investigated. Distributions of the yield strength and the ultimate strength of the SHN490 rolled section were relatively uniform comparing to those of the SM490 rolled section Brittle fracture in the weldments of the test specimens was not observed. Instead, fracture occurred at heat-affected zones or the stress-concentrated point near the weld access hole of the beam flanges. In the case of identical rolled-section specimens, the rotational capacity and dissipated energy of the WUF-W connection was larger than those of the WUF-B connection. In the case of identical connection types, the rotational capacity and dissipated energy of the SHN490 section connection was larger than those of the WUF-B section connection.
국내 현실에 적합한 내진 접합부 상세 개발과 평가를 위하여 국내 중저층 철골건물에 적용되는 단면을 갖는 보와 기둥으로 구성 된 접합부 실험체를 선정하여 반복재하 실험을 수행하였다. 실험변수는 접합부 형식과 강종이며 새로 개발된 내진용 형강(SHN490)과 기존 형강 (SM490)의 성능 차이를 비교하였다. 소재인장시험결과에 의하면 SHN490 형강의 항복강도와 인장강도의 분포는 SM490형강의 분포보다 균일한 것으로 평가되었다. 접합부 실험체의 용접부에서의 취성파괴는 관찰되지 않았고 소정의 소성변형 능력을 발휘한 후 보 플랜지의 열영향부나 용 접접근공의 응력집중부위에서 파단이 발생하였다. 동일한 강종으로 구성된 실험체의 경우, 보의 웨브가 볼트에 의하여 기둥에 연결된 접합부 (WUF-B)보다는 용접에 의하여 연결된 접합부(WUF-W)의 회전과 에너지 소산능력이 더 컸다. 또한 동일한 접합부 형식의 실험체에서는 SM490 형강으로 구성된 실험체보다는 SHN490 실험체의 회전과 에너지 소산능력이 더 컸다.