New Control Scheme for the Wind-Driven Doubly Fed Induction Generator under Normal and Abnormal Grid Voltage Conditions

  • Ebrahim, Osama S. (Energy and Power Electronics Applied Research Lab (ePEARL), Queen's University) ;
  • Jain, Praveen K. (Energy and Power Electronics Applied Research Lab (ePEARL), Queen's University) ;
  • Nishith, Goel (Cistel Technology)
  • 발행 : 2008.02.20

초록

The wind-driven doubly fed induction generator (DFIG) is currently under pressure to be more grid-compatible. The main concern is the fault ride-through (FRT) requirement to keep the generator connected to the grid during faults. In response to this, the paper introduces a novel model and new control scheme for the DFIG. The model provides a means of direct stator power control and considers the stator transients. On the basis of the derived model, a robust linear quadratic (LQ) controller is synthesized. The control law has proportional and integral actions and takes account of one sample delay in the input owing to the microprocessor's execution time. Further, the influence of the grid voltage imperfection is mitigated using frequency shaped cost functional method. Compensation of the rotor current pulsations is proposed to improve the FRT capability as well as the generator performance under grid voltage unbalance. As a consequence, the control system can achieve i) fast direct power control without instability risk, ii) alleviation of the problems associated with the DFIG operation under unbalanced grid voltage, and iii) high probability of successful grid FRT. The effectiveness of the proposed solution is confirmed through simulation studies on 2MW DFIG.

키워드

참고문헌

  1. L. Gertmar, L. Liljestrand, and H. Lendenmann,' Wind energy powers-That-Be successor generation in globalization,' IEEE Trans. On Energy Conversion, vol. 22, no. 1, pp. 13-28, March 2007 https://doi.org/10.1109/TEC.2006.889601
  2. American Wind Energy Association, 'AWEA electrical guide to utility scale wind turbines,' March 2005
  3. R. Datta and V. T. Ranganthan,' Variable speed wind generation using doubly fed wound rotor induction machine: a comparison with alternative scheme,' IEEE Trans. On Energy Conversion, vol. 17, no. 3, pp. 414-421, Sept. 2002 https://doi.org/10.1109/TEC.2002.801993
  4. S. Muller, M. Deicke, and R. W. De Doncker, 'Doubly fed induction generator systems for wind turbines,' IEEE Ind. Appl. Mag., vol. 8, no. 3, pp. 26-33, May/Jun. 2002
  5. A. Peterson, 'Analysis, modeling and control of doubly fed induction generators for wind turbines,' Ph. D. dissertation, Chalmers Univ. of Technology, Gothenburg, Sweden, 2005
  6. C. Abbey, J. Chahwan, M. Gattrell, and G. Joos, 'Transient modeling and simulation of wind turbine generator and storage systems,' CIGRA Canada, Conf. On Power systems, no. 042, pp. 3-8, Oct. 2006
  7. L. Xu and C. Wei, ' Torque and reactive power control of a doubly fed induction machine by position sensorless scheme,' IEEE Trans. On Ind. Appl., vol. 31, no. 3, pp. 636-642, May/Jun.1995 https://doi.org/10.1109/28.382126
  8. B. Hopfensperger, D. J. Atkinson, and R. A. Lakin, 'Stator flux oriented control of a doubly fed induction machine with and without position encoder,' Proc. Inst. Elect. Eng., vol. 147, pp. 241-250, Jul. 2000
  9. A. Petersson, L. Harnefors, and T. Thiringer,' Comparison between stator-flux and grid-flux-oriented rotor current control of doubly-fed induction generators,' in proc. Of PESC'04, pp.482-486, Aachen, Germany, 2004
  10. T. Brekken, and N. Mohan, 'Control of a doubly fed induction wind generator under unbalanced grid voltage conditions,' IEEE Trans. On Energy Conversion, vol. 22, no. 1, pp-129-135, March 2007 https://doi.org/10.1109/TEC.2006.889550
  11. L. Xu and Y. Wang, 'Dynamic modeling and control of DFIG based wind turbines under unbalanced network conditions,' IEEE Trans. On Power Systems, vol. 22, no. 1, pp 314-323, March 2007 https://doi.org/10.1109/TPWRS.2006.889113
  12. J. D. Rose and I. A. Hiskens, 'challenges of integrating large amount of wind power,' 1st Ann. IEEE systems Conf., pp. 259-265, April 2007
  13. G. Joos, 'Review of grid codes,' Int. Conf. on Integration of RE and DER (IRED04), Brussels, Belgium, Dec. 2004
  14. R. Zavadil, N. Miller, A. Ellis, and E. Muljadi, 'Making connections,' IEEE Power & Energy Mag., vol. 3, no. 6, pp. 26-37, Nov./Dec. 2005 https://doi.org/10.1109/MPAE.2005.1524618
  15. D. Xiang, L. Ran, P. J. Tavner, and S. Yang,' Control of a doubly fed induction generator in a wind turbine during grid fault ride-through,' IEEE Trans. On Energy Conversion, vol. 21, no. 3, pp. 652-662, 2006 https://doi.org/10.1109/TEC.2006.875783
  16. H. Bankar, C. Lou and B. T. Ooi, 'steady state stability analysis of doubly fed induction generators under decoupled P-Q control,' IEE Proc. Electric Power Appl., vol. 153, no.. 2, pp. 300-306, 2006
  17. M. Heller and W. Schumacher, 'Stability analysis of doubly-fed induction machines in stator flux reference frame,' in Proc. of EPE'97, vol. 2, pp. 707-710, Torndheim, Noway, Sept. 1997
  18. L. Congwei, W. Haiqing, S. Xudong, and L. Fahai, 'Research of stability of double fed induction motor vector control system,' in Proc. of ICEMS'01, vol. 2, pp. 1203-1206, Shenyang, China, Aug. 2001
  19. A. Petersson, L. Harnefors, and T. Thiringer, 'Evaluation of current control methods for wind turbines using doubly fed induction machines,' IEEE Trans. On Power Electronics, vol.20, no. 1, pp.227-235, 2005 https://doi.org/10.1109/TPEL.2004.839785
  20. J. Holtz,' Sensorless control of induction machines —with or without signal injection? ' IEEE Trans. On Industrial Electr., vol. 53, no. 1, pp. 7-30, Feb. 2006 https://doi.org/10.1109/TIE.2005.862324
  21. N. K. Gupta, 'Frequency shaped cost functionals: Extension of linear quadratic Gaussian design methods,' J. Guidance Contr., vol. 3, no. 6, 1980
  22. Osama S. Ebrahim, Mohamed M. Negm and Mohamed Z. Youssef 'An Improved DTC scheme for The AC Drives Based on Optimal Preview Control Technique,' ISIE2006, July 2006
  23. Mohamed M. Negm, Mohamed F. Salem and Osama S. Ebrahim,' Experimental investigation of high performance induction motor control based on optimal preview controller,' IEEE ICIT '04, Vol. 1, pp. 334-340, 2004
  24. R. F. Stengel,' Optimal control and estimation,' Dover publications, New York, 1994, book
  25. H. Akagi, S. Ogasawara, H. Kim, ' The theory of instantaneous power in three-phase four wire systems: a comprehensive approach,' in proc. IEEE-PESC Conf., pp.431-439, 1999