DOI QR코드

DOI QR Code

MREIT of Postmortem Swine Legs using Carbon-hydrogel Electrodes

  • Minhas, Atul S. (College of Electronics and Information, Kyung Hee University) ;
  • Jeong, Woo-Chul (College of Electronics and Information, Kyung Hee University) ;
  • Kim, Young-Tae (College of Electronics and Information, Kyung Hee University) ;
  • Kim, Hyung-Joong (College of Electronics and Information, Kyung Hee University) ;
  • Lee, Tae-Hwi (College of Electronics and Information, Kyung Hee University) ;
  • Woo, Eung-Je (College of Electronics and Information, Kyung Hee University)
  • 발행 : 2008.12.31

초록

Magnetic resonance electrical impedance tomography(MREIT) has been suggested to produce cross-sectional conductivity images of an electrically conducting object such as the human body. In most previous studies, recessed electrodes have been used to inject imaging currents into the object. An MRI scanner was used to capture induced magnetic flux density data inside the object and a conductivity image reconstruction algorithm was applied to the data. This paper reports the performance of a thin and flexible carbon-hydrogel electrode that replaces the bulky and rigid recessed electrode in previous studies. The new carbon-hydrogel electrode produces a negligible amount of artifacts in MR and conductivity images and significantly simplifies the experimental procedure. We can fabricate the electrode in different shapes and sizes. Adding a layer of conductive adhesive, we can easily attach the electrode on an irregular surface with an excellent contact. Using a pair of carbon-hydrogel electrodes with a large contact area, we may inject an imaging current with increased amplitude primarily due to a reduced average current density underneath the electrodes. Before we apply the new electrode to a human subject, we evaluated its performance by conducting MREIT imaging experiments of five swine legs. Reconstructed conductivity images of the swine legs show a good contrast among different muscles and bones. We suggest a future study of human experiments using the carbon-hydrogel electrode following the guideline proposed in this paper.

키워드

참고문헌

  1. N. Zhang, Electrical Impedance Tomography based on Current Density Imaging, Toronto, Canada: MS Thesis, Dept. of Elec. Eng, 1992
  2. E.J. Woo, S.Y. Lee, and C.W. Mun, "Impedance tomography using internal current density distribution measured by nuclear magnetic resonance", SPIE, vol. 2299, pp. 377-385, 1994 https://doi.org/10.1117/12.179269
  3. Y.Z. Ider, and O. Birgul, "Use of the magnetic field generated by the internal distribution of injected currents for electrical impedance tomography (MR-EIT)", Elektrik, vol. 6, pp. 215-225, 1998
  4. O. Kwon, E.J. Woo, J.R. Yoon, and J.K. Seo, "Magnetic resonance electrical impedance tomography (MREIT): simulation study of J-substitution algorithm", IEEE Trans. Biomed. Eng., vol. 49, pp. 160-167, 2002 https://doi.org/10.1109/10.979355
  5. E.J. Woo, J.K. Seo, and S.Y. Lee, "Magnetic resonance electrical impedance tomography (MREIT) in Holder D ed.", Electrical Impedance Tomography: Methods, History and Applications, Bristol, UK: IOP Publishing, 2005
  6. H.J. Kim, B.I. Lee, Y. Cho, Y.T. Kim, B.T. Kang, H.M. Park, S.Y. Lee, J.K. Seo, and E.J. Woo, "Conductivity imaging of canine brain using a 3 T MREIT system: postmortem experiments", Physiol. Meas., vol. 28, pp. 1341-1353, 2007 https://doi.org/10.1088/0967-3334/28/11/002
  7. H.J. Kim, T.I. Oh, Y.T. Kim, B.I. Lee, E.J. Woo, J.K. Seo, S.Y. Lee, O. Kwon, C. Park, B.T. Kang, and H.M. Park, "In vivo electrical conductivity imaging of a canine brain using a 3T MREIT system", Physiol. Meas., vol. 29, pp. 1145-1155, 2008 https://doi.org/10.1088/0967-3334/29/10/001
  8. B.I. Lee, S.H. Oh, E.J. Woo, S.Y. Lee, M.H. Cho, O. Kwon, J.K. Seo, J.Y. Lee, and W.S. Baek, "Three-dimensional forward solver and its performance analysis in magnetic resonance electrical impedance tomography (MREIT) using recessed electrodes", Phys. Med. Biol., vol. 48, pp. 1971-1986, 2003 https://doi.org/10.1088/0031-9155/48/13/309
  9. S.H. Oh, B.I. Lee, E.J. Woo, S.Y. Lee, M.H. Cho, O. Kwon,and J.K. Seo, "Conductivity and current density image reconstruction using harmonic Bz algorithm in magnetic resonance electrical impedance tomography", Phys. Med. Biol., vol. 48, pp. 3101- 3116, 2003 https://doi.org/10.1088/0031-9155/48/19/001
  10. S.H. Oh, B.I. Lee, T.S. Park, S.Y. Lee, E.J. Woo, M.H. Cho, O. Kwon, and J.K. Seo, "Magnetic resonance electrical impedance tomography at 3 Tesla field strength", Mag. Reson. Med., vol. 51, pp. 1292-1296, 2004 https://doi.org/10.1002/mrm.20091
  11. S.H. Oh, B.I. Lee, E.J. Woo, S.Y. Lee, T.S. Kim, O. Kwon, and J.K. Seo, "Electrical conductivity images of biological tissue phantoms in MREIT", Physiol. Meas., vol. 26, S279-288, 2005 https://doi.org/10.1088/0967-3334/26/2/026
  12. T.I. Oh, W. Koo, K.H. Lee, S.M. Kim, J. Lee, S.W. Kim, J.K. Seo, and E.J. Woo, "Validation of a multi-frequency electrical impedance tomography (mfEIT) system KHU Mark1: impedance spectroscopy and time-difference imaging", Physiol. Meas., vol. 29, pp. 295-307, 2008 https://doi.org/10.1088/0967-3334/29/3/002
  13. C. Park, B.I. Lee, O. Kwon, and E.J. Woo, "Measurement of induced magnetic flux density using injection current nonlinear encoding (ICNE) in MREIT", Physiol. Meas., vol. 28, pp. 117-127, 2006 https://doi.org/10.1088/0967-3334/28/2/001
  14. T.I. Oh, Y. Cho, Y.K. Hwang, S.H. Oh, E.J. Woo, and S.Y. Lee, "Improved current source design to measure induced magnetic flux density distributions in MREIT", J. Biomed. Eng. Res., vol. 27, pp. 30-37, 2006
  15. R. Sadleir, S. Grant, S.U. Zhang, B.I. Lee, H.C. Pyo, S.H. Oh, C. Park, E.J. Woo, S.Y. Lee, O. Kwon, and J.K. Seo, "Noise analysis in MREIT at 3 and 11 Tesla field strength", Physiol. Meas., vol. 26, pp. 875-884, 2005 https://doi.org/10.1088/0967-3334/26/5/023
  16. J.K. Seo, J.R. Yoon, E.J. Woo, and O. Kwon, "Reconstruction of conductivity and current density images using only one component of magnetic field measurements", IEEE Trans. Biomed. Eng., vol. 50, pp. 1121-1124, 2003 https://doi.org/10.1109/TBME.2003.816080
  17. L.A. Geddes, and L.E. Baker, "The specific resistance of biological material: a compendium of data for the biomedical engineer and physiologist", Med. Biol. Engng., vol. 5, pp. 271-293, 1967 https://doi.org/10.1007/BF02474537
  18. C. Gabriel, S. Gabriel, and E. Corthout, "The dielectric properties of biological tissues: I. literature survey", Phys. Med. Biol., vol. 41, pp. 2231-2249, 1996a https://doi.org/10.1088/0031-9155/41/11/001
  19. S. Gabriel, R.W. Lau, and C. Gabriel, "The dielectric properties of biological tissues: II. measurements in the frequency range 10Hz to 20GHz", Phys. Med. Biol., vol. 41, pp. 2251-2269, 1996b https://doi.org/10.1088/0031-9155/41/11/002
  20. S. Grimnes, and O.G. Martinsen, Bioimpedance and Bioelectricity Basics, London, UK: Academic Press, 2000
  21. G.C. Scott, M.L.G. Joy, R.L. Armstrong, and R.M. Henkelman, "Measurement of nonuniform current density by magnetic resonance", IEEE Trans. Med. Imag., vol. 10, pp. 362-374, 1991 https://doi.org/10.1109/42.97586
  22. G.C. Scott, M.L.G. Joy, R.L. Armstrong, and R.M. Hankelman, "Sensitivity of magnetic resonance current density imaging", J. Magn. Reson., vol. 97, pp. 235-254, 1992
  23. S.H. Lee, J.K. Seo, C. Park, B.I. Lee, E.J. Woo, S.Y. Lee, O. Kwon, and J. Hahn, "Conductivity image reconstruction from defective data in MREIT: numerical simulation and animal experiment", IEEE Trans. Med. Imag., vol. 25, pp. 168-176, 2006 https://doi.org/10.1109/TMI.2005.862150