참고문헌
- N. Zhang, Electrical Impedance Tomography based on Current Density Imaging, Toronto, Canada: MS Thesis, Dept. of Elec. Eng, 1992
- E.J. Woo, S.Y. Lee, and C.W. Mun, "Impedance tomography using internal current density distribution measured by nuclear magnetic resonance", SPIE, vol. 2299, pp. 377-385, 1994 https://doi.org/10.1117/12.179269
- Y.Z. Ider, and O. Birgul, "Use of the magnetic field generated by the internal distribution of injected currents for electrical impedance tomography (MR-EIT)", Elektrik, vol. 6, pp. 215-225, 1998
- O. Kwon, E.J. Woo, J.R. Yoon, and J.K. Seo, "Magnetic resonance electrical impedance tomography (MREIT): simulation study of J-substitution algorithm", IEEE Trans. Biomed. Eng., vol. 49, pp. 160-167, 2002 https://doi.org/10.1109/10.979355
- E.J. Woo, J.K. Seo, and S.Y. Lee, "Magnetic resonance electrical impedance tomography (MREIT) in Holder D ed.", Electrical Impedance Tomography: Methods, History and Applications, Bristol, UK: IOP Publishing, 2005
- H.J. Kim, B.I. Lee, Y. Cho, Y.T. Kim, B.T. Kang, H.M. Park, S.Y. Lee, J.K. Seo, and E.J. Woo, "Conductivity imaging of canine brain using a 3 T MREIT system: postmortem experiments", Physiol. Meas., vol. 28, pp. 1341-1353, 2007 https://doi.org/10.1088/0967-3334/28/11/002
- H.J. Kim, T.I. Oh, Y.T. Kim, B.I. Lee, E.J. Woo, J.K. Seo, S.Y. Lee, O. Kwon, C. Park, B.T. Kang, and H.M. Park, "In vivo electrical conductivity imaging of a canine brain using a 3T MREIT system", Physiol. Meas., vol. 29, pp. 1145-1155, 2008 https://doi.org/10.1088/0967-3334/29/10/001
- B.I. Lee, S.H. Oh, E.J. Woo, S.Y. Lee, M.H. Cho, O. Kwon, J.K. Seo, J.Y. Lee, and W.S. Baek, "Three-dimensional forward solver and its performance analysis in magnetic resonance electrical impedance tomography (MREIT) using recessed electrodes", Phys. Med. Biol., vol. 48, pp. 1971-1986, 2003 https://doi.org/10.1088/0031-9155/48/13/309
- S.H. Oh, B.I. Lee, E.J. Woo, S.Y. Lee, M.H. Cho, O. Kwon,and J.K. Seo, "Conductivity and current density image reconstruction using harmonic Bz algorithm in magnetic resonance electrical impedance tomography", Phys. Med. Biol., vol. 48, pp. 3101- 3116, 2003 https://doi.org/10.1088/0031-9155/48/19/001
- S.H. Oh, B.I. Lee, T.S. Park, S.Y. Lee, E.J. Woo, M.H. Cho, O. Kwon, and J.K. Seo, "Magnetic resonance electrical impedance tomography at 3 Tesla field strength", Mag. Reson. Med., vol. 51, pp. 1292-1296, 2004 https://doi.org/10.1002/mrm.20091
- S.H. Oh, B.I. Lee, E.J. Woo, S.Y. Lee, T.S. Kim, O. Kwon, and J.K. Seo, "Electrical conductivity images of biological tissue phantoms in MREIT", Physiol. Meas., vol. 26, S279-288, 2005 https://doi.org/10.1088/0967-3334/26/2/026
- T.I. Oh, W. Koo, K.H. Lee, S.M. Kim, J. Lee, S.W. Kim, J.K. Seo, and E.J. Woo, "Validation of a multi-frequency electrical impedance tomography (mfEIT) system KHU Mark1: impedance spectroscopy and time-difference imaging", Physiol. Meas., vol. 29, pp. 295-307, 2008 https://doi.org/10.1088/0967-3334/29/3/002
- C. Park, B.I. Lee, O. Kwon, and E.J. Woo, "Measurement of induced magnetic flux density using injection current nonlinear encoding (ICNE) in MREIT", Physiol. Meas., vol. 28, pp. 117-127, 2006 https://doi.org/10.1088/0967-3334/28/2/001
- T.I. Oh, Y. Cho, Y.K. Hwang, S.H. Oh, E.J. Woo, and S.Y. Lee, "Improved current source design to measure induced magnetic flux density distributions in MREIT", J. Biomed. Eng. Res., vol. 27, pp. 30-37, 2006
- R. Sadleir, S. Grant, S.U. Zhang, B.I. Lee, H.C. Pyo, S.H. Oh, C. Park, E.J. Woo, S.Y. Lee, O. Kwon, and J.K. Seo, "Noise analysis in MREIT at 3 and 11 Tesla field strength", Physiol. Meas., vol. 26, pp. 875-884, 2005 https://doi.org/10.1088/0967-3334/26/5/023
- J.K. Seo, J.R. Yoon, E.J. Woo, and O. Kwon, "Reconstruction of conductivity and current density images using only one component of magnetic field measurements", IEEE Trans. Biomed. Eng., vol. 50, pp. 1121-1124, 2003 https://doi.org/10.1109/TBME.2003.816080
- L.A. Geddes, and L.E. Baker, "The specific resistance of biological material: a compendium of data for the biomedical engineer and physiologist", Med. Biol. Engng., vol. 5, pp. 271-293, 1967 https://doi.org/10.1007/BF02474537
- C. Gabriel, S. Gabriel, and E. Corthout, "The dielectric properties of biological tissues: I. literature survey", Phys. Med. Biol., vol. 41, pp. 2231-2249, 1996a https://doi.org/10.1088/0031-9155/41/11/001
- S. Gabriel, R.W. Lau, and C. Gabriel, "The dielectric properties of biological tissues: II. measurements in the frequency range 10Hz to 20GHz", Phys. Med. Biol., vol. 41, pp. 2251-2269, 1996b https://doi.org/10.1088/0031-9155/41/11/002
- S. Grimnes, and O.G. Martinsen, Bioimpedance and Bioelectricity Basics, London, UK: Academic Press, 2000
- G.C. Scott, M.L.G. Joy, R.L. Armstrong, and R.M. Henkelman, "Measurement of nonuniform current density by magnetic resonance", IEEE Trans. Med. Imag., vol. 10, pp. 362-374, 1991 https://doi.org/10.1109/42.97586
- G.C. Scott, M.L.G. Joy, R.L. Armstrong, and R.M. Hankelman, "Sensitivity of magnetic resonance current density imaging", J. Magn. Reson., vol. 97, pp. 235-254, 1992
- S.H. Lee, J.K. Seo, C. Park, B.I. Lee, E.J. Woo, S.Y. Lee, O. Kwon, and J. Hahn, "Conductivity image reconstruction from defective data in MREIT: numerical simulation and animal experiment", IEEE Trans. Med. Imag., vol. 25, pp. 168-176, 2006 https://doi.org/10.1109/TMI.2005.862150