References
- Ferrari, G., De Lazzri, C., Mimmo, R., Tosti, G., Ambrosi, D. and Gorczynska, K., 'A Computer Controlled Mock Circulatory Sysem for Mono and Biventricular Assist Device Testing,' International Journal of Artificial Organs, Vol. 21, No. 1, pp. 26-36, 1998 https://doi.org/10.1177/039139889802106s06
- Lehman, K. A., Antaki, J. F., Woodard, J. C. and Boston, J. R., 'A Starling-Responsive Mock Circulatory Loop for the Ventricular Assist Hamodynamic Simulation,' Waseda International Congress of Modeling and Simulation Technology for Artificial Organs, pp. 105-106, 1996
- Rosenberg, G., Phillips, W. M., Landis, D. L. and Pierce, W. S., 'Design and Evaluation of the Pennsylvania State University Mock Circulatory System,' ASAIO Journal, Vol. 4, No. 1, pp. 41-49, 1981
- Williams, J. L., Antaki, J. F., Boston, J. R., Williams, S. L., Woodward, J. C., Miller, P. J. and Kornos, R. L., 'Load Sensitive Mock Circulatory System for Left Ventricular Assist Device Controller Evaluation and Development,' Proceedings of the 16th Annual International Conference for the IEEE Engineering in Medicine and Biology Society, pp. 89-90, 1994
- Loh, M. and Yu, Y., 'Feedback Control Design of an Elastance-Based Mock Circulatory System for Heart Assist Device Controller Development,' under review, American Control Conference, pp. 1639-1644, 2004
- Baloa, L. A., Boston, J. R. and Antaki, J. F., 'Elastance-Based Control of a Mock Circulatory System,' Annals of Biomedical Engineering, Vol. 29, No. 3, pp. 244-251, 2001 https://doi.org/10.1114/1.1355275
- Liu, Y., Allure, P., Wood, H. and Olson, D., 'Construction of an Artificial Heart Pump Performance Test System,' Cardiovascular Eng., Vol. 6, No. 4, pp. 153-160, 2006
- Gwak, K. W., Paden, B., Noh, M. and Antaki, J., 'Fluidic Operational Amplifier for Mock Circulatory Systems,' IEEE Trans Control Systems Technology, Vol. 14, No. 4, pp. 602-612, 2006 https://doi.org/10.1109/TCST.2006.876624
- Choi, S., 'Modeling and Control of left Ventricular Assist System,' Ph.D. Thesis, University of Pittsburgh, 1998
- Suga, H. and Sagawa, K., 'Instantaneous Pressure-Volume Relationships and their ratio in the excised, supported canine left ventricle,' Circulation Research, Vol. 35, No. 1, pp. 117-126, 1974 https://doi.org/10.1161/01.RES.35.1.117
- Sagawa, K., Maugahan, L., Suga, H. and Sunagawa, K., 'Cardiac Contraction and the Pressure-Volume Relationship,' Cardiac Contraction and the Pressure-Volume Relationship, Oxford University Press, pp. 42-109, 1988
- Guyton, A. C. and Hall, J. E., 'Textbook of Medical Physiology,' 10th ed, Saunders, pp. 96-264, 2000