References
- Roberts WE, Marshall KJ, Mozsary PG. Rigid endosseous implant utilized as anchorage to protract molars and close an atrophic extraction site. Angle Orthod 1990;60:135-52
- Im DH, Kim YS, Cho MA, Kim KS, Yang SE. Interdisplinary treatment of Class III malocclusion using mini-implant: problem-oriented orthodontic treatment. Korean J Orthod 2007;37:305-14
- Park HS. The skeletal cortical anchorage using titanium microscrew implants. Korean J Orthod 1999;29:699-706
- Park HS. A new protocal of the sliding mechanics with Micro- Implant Anchorage (M.I.A). Korean J Orthod 2000;30:677-85
- Cordioli G, Majzoub Z, Piatelli A, Scarano A. Removal torque and histomorphometric investigation of 4 different titanium surfaces: an experimental study in the rabbit tibia. Int J Oral Maxillofac Implants 2000;15:668-74
- Lim YJ, Oshida Y, Andres CJ, Barco MT. Surface characterizations of variously treated titanium materials. Int J Oral Maxillofac Implants 2001;16:333-42
- Cho SA, Park KT. The removal torque of titanium screw inserted in rabbit tibiatreated by dual acid etching. Biomaterials 2003;24:3611-7 https://doi.org/10.1016/S0142-9612(03)00218-7
- Abrahamsson I, Berglundh T, Linder E, Lang NP, Lindhe J. Early bone formation adjacent to rough and turned endosseous implant surfaces. An experimental study in the dog. Clin Oral Implants Res 2004;15:381-92 https://doi.org/10.1111/j.1600-0501.2004.01082.x
- Lim SA, Cha JY, Hwang CJ. Comparison of insertion torque regarding changes in shape, diameter, and length of orthodontic miniscrews. Korean J Orthod 2007;37:89-97
- Song YY, Cha JY, Hwang CJ. Evaluation of insertion torque and Pull-out strength of mini-screws according to different thickness of artificial cortical bone. Korean J Orthod 2007;37:5-15
- Umemori M, Sugawara J, Mitani H, Nagasaka H, Kawamura H. Skeletal anchorage system for open-bite correction. Am J Orthod Dentofacial Orthop 1999;115:166-74 https://doi.org/10.1016/S0889-5406(99)70345-8
- Kyung SH, Lim JK, Park YC. The use of miniscrew as an anchorage for the orthodontic tooth movement. Korean J Orthod 2001;31:415-24
- Cho JH. Effects on orthodontic miniscrew implants according to the timing of force application thesis. Seoul: Yonsei University; 2003
- Sun SB, Kang YG, Kim SH, Mo SS, Kook YA. Influence of immediate loading on the removal torque value of mini-screws. Korean J Orthod 2007;37:400-6
- Chung KR, Kim SH, Kook YA. The C-orthodontic micro- implant. J Clin Orthod 2004;38:478-86
- Oh NH, Kim SH, Kook YA, Lee KH, Kang YG, Mo SS. Removal torque of sandblasted large grit, acid etched treated mini-implant. Korean J Orthod 2006;36:324-30
- Maino BG, Bednar J, Pagin P, Mura P. The spider screw for skeletal anchorage. J Clin Orthod 2003;37:90-7
- Yoon BS, Choi BH, Lee YU, Kim KN, Shim HB, Park JH. A study on Titaniuim Miniscrew as Orthodontic Anchorage; An experimental investigation in dogs. Korean J Orthod 2001;31:517-23
- Lim JW, Kim WS, Kim IK, Son CY, Byun HI. Three dimensional finite element method for stress distribution on the length and diameter of orthodontic miniscrew and cortical bone thickness. Korean J Orthod 2003;33:11-20
- Huja SS, Litsky AS, Beck FM, Johnson KA, Larsen PE. Pull-out strength of monocortical screws placed in the maxillae and mandibles of dogs. Am J Orthod Dentofacial Orthop 2005;127:307-13 https://doi.org/10.1016/j.ajodo.2003.12.023
- Kim SH, Cho JH, Chung KR, Kook YA, Nelson G. Evaluation of the removal torque values of surface-treated mini-implants after loading. Am J Orthod Dentofacial Orthop 2008;134:36-43 https://doi.org/10.1016/j.ajodo.2006.07.038
- Kim JW, Ahn SJ, Chang YI. Histomorphometric and mechanical analyses of the drill-free screw as orthodontic anchorage. Am J Orthod Dentofacial Orthop 2005;128:190-4 https://doi.org/10.1016/j.ajodo.2004.01.030
- Gurgel BC, Goncalves PF, Pimentel SP, Nociti FH, Sallum EA, Sallum AW, et al. An oxidized implant surface may improve bone-to-implant contact in pristine bone and bone defects treated with guided bone regeneration: an experimental study in dogs. J Periodontol 2008;79:1225-31 https://doi.org/10.1902/jop.2008.070529
- Iamoni F, Rasperini G, Trisi P, Simion M. Histomorphometric analysis of a half hydroxyapatite-coated implant in humans: a pilot study. Int J Oral Maxillofac Implants 1999;14:729-35
- Sennerby L, Thomsen P, Ericson LE. A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone. Int J Oral Maxillofac Implants 1992;7:62-71
- Costa A, Raffaini M, Melsen B. Miniscrews as orthodontic anchorage: a preliminary report. Int J Adult Orthod Orthognath Surg 1998;13:201-9
- Melsen B, Verna C. A rational approach to orthodontic anchorage. Prog Orthod 1999;1:10-22 https://doi.org/10.1034/j.1600-9975.2000.d01-4.x
Cited by
-
즉시 부하 교정용 미니임플랜트의 안정성 평가를 위한 Periotest
$^{(R)}$ 의 유효성 vol.40, pp.3, 2008, https://doi.org/10.4041/kjod.2010.40.3.167 - The effects of different pilot-drilling methods on the mechanical stability of a mini-implant system at placement and removal: a preliminary study vol.41, pp.5, 2008, https://doi.org/10.4041/kjod.2011.41.5.354
- Three-dimensional finite element analysis for determining the stress distribution after loading the bone surface with two-component mini-implants of varying length vol.41, pp.6, 2011, https://doi.org/10.4041/kjod.2011.41.6.423