References
- Adell R, Lekholm U, Rockler B, Branemark PI. A 15-year study of osseointegtated implants in the treatment of the edentulous saw. Int J Oral Surg 1981;10:387-416 https://doi.org/10.1016/S0300-9785(81)80077-4
- Albrektsson T, Branemark PI, Hansson HA, Lindstro m J. Osseointegrated titanium implants: requirements for ensuring a long-lasting, direct bone to implant anchorage in man. Acta Orthop Scand 1981;52:155-70 https://doi.org/10.3109/17453678108991776
- Meredith N. Assessment of implant stability as a prognostic determinanat. Int J Prosthodont 1998;11:491-501
- Friberg B, Sennerby L, Linden B, Grondahl K, Lekholm U. Stability measurements of one-stage Branemark implants during healing in mandibles. A clinical resonance frequency analysis study. Int J Oral Maxillofac Surg 1999;28:266-72 https://doi.org/10.1016/S0901-5027(99)80156-8
- Meredith N. A review of nondestructive test methods and their application to measure the stability and osseiontegration of bone anchored endosseous implants. Crit Rev Biomed Eng 1998;26:275-91 https://doi.org/10.1615/CritRevBiomedEng.v26.i4.20
- Friberg B. Sennerby L. Meredith N. Lekholm U. A comparison between cutting torque and resonance frequency measurement of maxillary implants: A 20-month clinical study. Int J Oral Maxillofac Surg 1999;28:297-303 https://doi.org/10.1016/S0901-5027(99)80163-5
- Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Implants Res 1997;8: 226-33 https://doi.org/10.1034/j.1600-0501.1997.080309.x
- Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res 1996;7:261-7 https://doi.org/10.1034/j.1600-0501.1996.070308.x
- Barewal RM, Oates TW, Meredith N, Cochran DL. Resonance frequency analysis of implant stability in vivo on implants with a sandblasted and acid-etched surfaces. Int J Oral Maxillofac Implants 2003;18:641-5
- O'Sullivan D, Sennerby L, Meredith N. Measurements comparing the initial stability of five designs of dental implant: a human cadaver study. Clin Implant Dent Relat Res 200;2:85-92 https://doi.org/10.1111/j.1708-8208.2000.tb00110.x
- da Cunha HA, Francischone CE, Filho HN, de Oliveira RC. A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and tiunite single-tooth implants under immediate loading. Int Oral Maxillofac Implants 2004;19:578-85
- Kim SK, Kwon JY, Heo SJ, Koak JY, Lee JH. Software for measurement of load developed with implant installation. Intellectual property rights 2007-01-199-004156, 2007
- Kim SK, Kwon JY, Heo SJ, Koak JY, Lee JH. Software for measurement of energy absorbed by bone. Intellectual property rights 2007-01-199-004155, 2007
- Sennerby L, Thomsen P, Ericson LE. A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone. Int J Oral Maxillofac Implants 1992;7:62-71
- O'sullivan D, Sennerby L, Meredith N. Influence of implant taper on the primary and second stability of osseointegrated titanium implants. Clin Oral Impl Res 2004;15:474-80 https://doi.org/10.1111/j.1600-0501.2004.01041.x
- Ostman PO, Hellman M, Wendelhag I, Sennerby L. Resonance Frequency Analysis Measurements of Implants at Placement Surgery. Int J Prosthodont 2006;19:77-83
- Lim SA, Cha JY, Hwang CJ. Insertion torque of orthodontic miniscrews according to changes in shape, diameter, and length. Angle Orthod 2008;78:234-40 https://doi.org/10.2319/121206-507.1
- Walker J. Applied mechanics London: Hodder and Stoughton; 1972.pp 41-2
- O'Sullivan D, Sennerby L, Jagger D, Meredith N. A comparison of two methods of enhancing implant primary stability. Clin Implant Dent Relat Res 2004;6:48-57 https://doi.org/10.1111/j.1708-8208.2004.tb00027.x
Cited by
- A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables vol.2, pp.4, 2010, https://doi.org/10.4047/jap.2010.2.4.148
- The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia vol.3, pp.2, 2011, https://doi.org/10.4047/jap.2011.3.2.76
- The relationship between implant stability quotient values and implant insertion variables: a clinical study vol.39, pp.2, 2011, https://doi.org/10.1111/j.1365-2842.2011.02255.x