Optimization of Detention Facilities by Using Multi-Objective Genetic Algorithms

다목적 유전자 알고리즘을 이용한 우수유출 저류지 최적화 방안

  • Chung, Jae-Hak (National Institute for Disaster Prevention) ;
  • Han, Kun-Yeun (Dept. of Civil Engineering, Kyungpook Univ) ;
  • Kim, Keuk-Soo (River & Coast Research Division, Korea Institute of Construction Technology)
  • 정재학 (국립방재교육연구원 방재연구소) ;
  • 한건연 (경북대학교 공과대학 토목공학과) ;
  • 김극수 (한국건설기술연구원 하천.해안연구실)
  • Published : 2008.12.31

Abstract

This study is for design of the detention system distributed in a watershed by the Multi-Objective Genetic Algorithms(MOGAs). A new model is developed to determine optimal size and location of detention. The developed model has two primary interfaced components such as a rainfall runoff model to simulate water surface elevation(or flowrate) and MOGAs to get the optimal solution. The objective functions used in this model depend on the peak flow and storage of detention. With various constraints such as structural limitations, capacities of storage and operational targets. The developed model is applied at Gwanyang basin within Anyang watershed. The simulation results show the maximum outlet reduction is occurred at detention facilities located in upper reach of watershed in the peak discharge rates. It is also reviewed the simultaneous construction of an off-line detention and an on-line detention. The methodologies obtained from this study will be used to control the flood discharges and to reduce flood damage in urbanized watershed.

본 연구의 목적은 다목적 유전자 알고리즘을 이용하여 우수유출 저류지를 소유역에 분담하여 설치 계획하는데있다. 이를 위해 우수유출 저류지의 위치 및 규모를 최적화하기 위한 모형을 개발하였다. 이 모형은 크게 2가지로 나뉘어 지는데, 유역유출모형과 최적해를 구하기 위하여 도입한 다목적 유전자 알고리즘(MOGAs)이다. 이러한 최적화 모형을 모의하기 위하여 목적함수는 첨두유출량과 저류지 저류용량의 함수로 설정하고, 제한조건은 기본적으로 구조적 제한과 저류용량 및 운영목적에 따라 설정하였다. 본 연구를 위해 만들어진 최적화 모형은 안양시 관양유역에 실제 적용해 보았으며, 그 결과 주어진 제약조건내에서 상류지역에 저류지가 설치되는 경우가 최적값으로 나타난 것을 통해 적절하게 잘 모의된 것으로 보인다. 그밖에 On-line 및 Off-line 저류지가 동시에 건설되는 경우에도 함께 최적화 모의가 가능한지도 살펴보았다. 본 연구를 통해 제시한 방법론은 향후 도시유역내의 홍수피해 저감계획시 활용될 수 있을 것이다.

Keywords

References

  1. 김태순, 허준행 (2005). “NSGA-II를 이용한 한강수계 저수지군 운영방안에 관한 연구.” 대한토목학회 정기학술대회 논문집, 대한토목학회, pp. 2369-2372
  2. 박민규, 유철상, 박창열 (2007). “저류지 예비설계에 관한 비교 연구.” 한국수자원학회 학술발표회 논문집, 한국수자원학회, pp. 383-387
  3. 박봉진, 차형선, 김주환 (1997). “유전자 알고리즘을 이용한 저류함수모형의 매개변수 추정에 관한 연구.” 한국수자원학회 논문집, 한국수자원학회, 제30권, 제4호, pp. 347-355
  4. 이길성, 정은성 (2004). “유전자 알고리즘을 이용한 댐군의 최적운영방안.” 대한토목학회논문집, 대한토목학회, 제24권, 제1B호, pp. 9-17
  5. 이정식, 이재준, 김규호, 오석훈 (1995). “도시유역에서 지체저류시설의 수문학적 설계에 관한 연구.” 한국수자원학회논문집, 한국수자원학회, 제28권, 제2호, pp. 159-173
  6. 이재준, 곽창재, 김호년, 이상원 (2007). “도시유역 저류지의 위치관련 변수의 수문학적 해석.” 대한토목학회 정기학술대회 논문집, 대한토목학회, pp. 1405-1408
  7. El-Said Mohamed, Said Ahmed (2006). Real time optimal operation of Reservoir-river system under flooding conditions, Arizona State University
  8. Esat, V., and Hall, M. J. (1994). "Water resources system optimization using genetic algorithms." Proceedings of the 1st International Conference on Hydroinformatics, A. Verwey, Delft, pp 225-232
  9. Fahmy, H. S., King, J. P., Wentzel, M. W., and Seton, J. A. (1994). "Economic optimization of river management using genetic algorithms." Paper No. 943034, ASAE 1994 Int. Summer Meeting, Am. Soc. of Agricultural Engineers. St. Joseph, Mich
  10. Mays, L.W., Unver, O.L. and Lansey, K.E. (1986). Report of real time flood management model for lower colorado river-highland lake systems, Bereau of Engineering Research Center for Research in Water Resources and Department of Civil Engineering, University of Texas at Austin
  11. Unver, O.L. and Mays, L.W. (1990). "Model for real-time Optimal Flood Control Operation of a Reservoir System." Water Resources Management, Vol. 4. Kluwer. Dordrecht, The Netherlands. pp. 21-46 https://doi.org/10.1007/BF00429923
  12. Wardlaw, R and Sharif, M(1999). "Evaluation of genetic algorithms for optimal reservoir system operation.” Journal of Water Resources Planning & Management, ASCE, Vol. 125, No. 1, pp. 25-33 https://doi.org/10.1061/(ASCE)0733-9496(1999)125:1(25)
  13. Windsor, J. S.(1973). "Optimization Model for the Operation of Flood Control Systems." Water Resources Research, Vol. 9, pp. 1219-1226 https://doi.org/10.1029/WR009i005p01219

Cited by

  1. Determination of Optimal Location and Capacity of Detention Facilities vol.70, 2014, https://doi.org/10.1016/j.proeng.2014.02.115
  2. Analysis of Flood Level Mitigation due to the Naju Retention-Basin by Numerical Model Application vol.15, pp.9, 2014, https://doi.org/10.5762/KAIS.2014.15.9.5801
  3. Determining optimal locations for rainwater storage sites with the goal of reducing urban inundation damage costs vol.21, pp.6, 2017, https://doi.org/10.1007/s12205-016-0922-6
  4. Numerical Model Application for Analysis of Flood Level Mitigation due to Retention-Basin vol.15, pp.1, 2014, https://doi.org/10.5762/KAIS.2014.15.1.495
  5. Effect of the Optimal Small-Scale Distributed Ponds to Reduce Urban Flooding vol.16, pp.4, 2016, https://doi.org/10.9798/KOSHAM.2016.16.4.323
  6. Flood Reduction in Urban Drainage Systems: Cooperative Operation of Centralized and Decentralized Reservoirs vol.8, pp.10, 2016, https://doi.org/10.3390/w8100469
  7. Design and Operation of Decentralized Reservoirs in Urban Drainage Systems vol.9, pp.4, 2017, https://doi.org/10.3390/w9040246
  8. Determination of Optimal Locations and Size of Storage in the Urban Sub-Surface using Genetic Algorithm vol.12, pp.3, 2012, https://doi.org/10.9798/KOSHAM.2012.12.3.285