DOI QR코드

DOI QR Code

A Study of Practical Use of Carbon Paste Biosensor Mechanically Reinforced by Chloroprene Rubber

  • Yoon, K.J. (Division of Applied Sciences, Cheongju University)
  • Published : 2008.11.20

Abstract

Keywords

References

  1. Qian, J. M.; Suo, A. L.; Yao, Y.; Jin, Z. H. Clin. Boichem. 2004, 37, 155 https://doi.org/10.1016/j.clinbiochem.2003.10.013
  2. Yang, Y. H.; Yang, M. H.; Wang, H.; Jiang, J. H.; Shen, G.; Yu, R. Q. Sens. Actuators B 2004, 102, 162 https://doi.org/10.1016/j.snb.2004.04.016
  3. Ghica, M. E.; Christopher, M. A. B. Anal. Chim. Acta 2005, 532, 145 https://doi.org/10.1016/j.aca.2004.10.058
  4. Mailley, P.; Cummings, E. A.; Mailley, S.; Cosnier, S.; Eggins, B. R.; McAdams, E. Biochemistry 2004, 63, 291
  5. Wang, B. Q.; Dong, S. J. J. Electroanal. Chem. 2000, 487, 45 https://doi.org/10.1016/S0022-0728(00)00152-2
  6. Liu, M. Q.; Jiang, J. H.; Feng, Y. L.; Shen, G. L.; Yu, R. Q. Chin. J. Anal. Chem. 2007, 35, 1435 https://doi.org/10.1016/S1872-2040(07)60086-3
  7. Yoon, K. J. J. Kor. Chem. Soc. 2004, 48, 654 https://doi.org/10.5012/jkcs.2004.48.6.654
  8. Kwon, H. S.; Jin, E. H.; Yoon, K. J.; Park, Y. N. J. Kor. Chem. Soc. 2005, 49, 224 https://doi.org/10.5012/jkcs.2005.49.2.224
  9. Choi, S. Y.; Yoon, K. J. Elastomer 2006, 41, 231
  10. Yoon, K. J. Elastomer 2007, 42, 112
  11. Yoon, K. J. Anal. Sci. & Tech. 2007, 20, 49
  12. Yoon, K. J. J. Kor. Chem. Soc. 2008, 52, 197 https://doi.org/10.5012/jkcs.2008.52.2.197
  13. Brydson, J. A. Rubbery Materials and Their Compoumds; Elsevier Science Publishers Ltd.: London and New York, 1988; p 210
  14. Diaz, A. N.; Peinado, M. C. R.; Minguez, M. C. T. Anal. Chim. Acta 1998, 363, 221 https://doi.org/10.1016/S0003-2670(98)00080-4
  15. Miao, Y.; Tan, S. N. Anal. Chim. Acta 2001, 437, 87 https://doi.org/10.1016/S0003-2670(01)00986-2

Cited by

  1. Application of Pine Peroxidase to the Amperometric Determination of Hydrogen Peroxidase vol.57, pp.3, 2013, https://doi.org/10.5012/jkcs.2013.57.3.329
  2. Enzymatic biosensors based on ingá-cipó peroxidase immobilised on sepiolite for TBHQ quantification vol.139, pp.9, 2014, https://doi.org/10.1039/c4an00028e
  3. Electrochemical Investigation of Carbon Paste Biosensor Bound with Natural Rubber Solution vol.30, pp.10, 2009, https://doi.org/10.5012/bkcs.2009.30.10.2457
  4. Amperometric study of hydrogen peroxide biosensor with butadiene rubber as immobilization matrix vol.16, pp.3, 2008, https://doi.org/10.1016/j.jiec.2010.01.016
  5. Electrochemical Investigation of Animal Tissue Embedded Biosensor Bound with Ethylene-Propylene Rubber vol.31, pp.10, 2008, https://doi.org/10.5012/bkcs.2010.31.10.2913
  6. 부타디엔 고무로 결합된 탄소반죽 바이오센서를 이용한 과산화수소의 전기화학적 정량 vol.23, pp.5, 2010, https://doi.org/10.5806/ast.2010.23.5.505
  7. Electrochemical kinetic study of amperometric hydrogen peroxide biosensor fabricated using SBR vol.17, pp.2, 2008, https://doi.org/10.1016/j.jiec.2011.02.016
  8. 클로로설폰화 폴리에틸렌으로 결합된 전류측정 탄소반죽 바이오센서 vol.55, pp.2, 2008, https://doi.org/10.5012/jkcs.2011.55.2.323
  9. Electrochemical kinetic analysis of the carbon paste enzyme electrode bound with butyl rubber vol.24, pp.2, 2008, https://doi.org/10.5806/ast.2011.24.2.113