Effect of Radiative Mean Temperature on Thermal Comfort of Underfloor Air Distribution System

바닥공조시스템에서 복사온도가 열적 쾌적성에 미치는 영향

  • Chung, Jae-Dong (Mechanical Engineering, Sejong University) ;
  • Hong, Hi-Ki (School of Mechanical and Industrial System Engineering, Kyung Hee University) ;
  • Yoo, Ho-Seon (Mechanical Engineering, Soongsil University)
  • 정재동 (세종대학교 기계공학과) ;
  • 홍희기 (경희대학교 기계산업시스템공학부) ;
  • 유호선 (숭실대학교 기계공학과)
  • Published : 2008.11.10

Abstract

Despite the fact that UFAD(Under Floor Air Distribution) systems have many benefits and are being applied in the field in increasing numbers, there is a strong need for an improved fundamental understanding of several key performance features of these systems. This study numerically investigates the effect of supplied air temperature and supplied flow rate on the performance of UFAD, especially focused on thermal comfort. Also this study has compared UFAD with conventional overhead air distribution system. In contrast to the well-mixed room air conditions of the conventional overheat system, UFAD system produces an overall floor-to-ceiling airflow pattern that takes advantage of the natural buoyancy produced by heat sources in the occupied zone and more efficiently removes heat loads and contaminants from the space. Thermal comfort parameters were evaluated by CFD approach and then PMV was computed to detect the occupants' thermal sensation. Results show that radiative mean temperature plays crucial role on the evaluating PMV. Until now, the radiative temperature has been the missing link between CFD and thermal comfort, but the present study paves the way for overcoming this weakness.

Keywords

References

  1. Bausman, F. and Webster, T., 2001, Outlook for Underfloor Air Distribution, ASHRAE Journal, Vol. 43, pp. 18-25
  2. Daly, A., 2002, Underfloor air distribution : Lessons learned, ASHRAE Journal, Vol. 44, pp. 21-24
  3. Kim, J., Kim, Y. and Yoo, H., 2000, Thermal comfort of the floor supply air conditioning system for different supply-return location s during cooling, Korean J. Air-Conditioning and Refrigeration Eng., Vol. 12, pp. 476-485
  4. Kim, S.-H. and Park., J.-I., 2005, Evaluation of indoor air environment by changing diffuser location and air temperature with under floor air conditioning system, Korean J. Air-Conditioning and Refrigeration Eng., Vol. 17, pp. 397-403
  5. Krepchin, I., 2001, Underfloor air systems gain foothold in North America, E. Source Report, ER-01-1. Boulder, Colo. : Financial Times Energy, Inc., January
  6. STAR-CD, User's Guide, 2001, Version 3.15
  7. Meyer, C., 2004, Being comfortable with STAR-CD, CD adapco Dynamics, Vol. 22, pp. 21-22
  8. Bauman, F. S., 2003, Underfloor air distibution (UFAD) design guide, ASHRAE, Inc.
  9. ISO Standard 7730, 1990, Moderate thermal environments-Determination of PMV and PPD indices and specification of the condition for thermal comfort, International Standards Organization, Geneva
  10. Fanger, P. O., 1970, Thermal comfort-Anaysis and application in environmental engineering, Danish Technical Press, Copenhagen, Denmark