A Survey on Characteristics of Distribution for Indoor Air Pollutants in Museum Environments

박물관내 실내공기오염물질의 분포 특성 실태조사

  • Kim, Yoon-shin (Hanyang University, College of Medicine, Occupational and Environmental Medicine) ;
  • Roh, Young-man (Hanyang University, College of Medicine, Occupational and Environmental Medicine) ;
  • Yoon, Young-hun (Hanyang University, College of Medicine, Occupational and Environmental Medicine) ;
  • Lee, Cheol-min (Hanyang University, College of Medicine, Occupational and Environmental Medicine) ;
  • Kim, Ki-yeon (Hanyang University, College of Medicine, Occupational and Environmental Medicine) ;
  • Kim, Jong-cheol (Hanyang University, College of Medicine, Occupational and Environmental Medicine) ;
  • Jeon, Hyoung-jin (Hanyang University, College of Medicine, Occupational and Environmental Medicine) ;
  • Sim, In-suk (Hanyang University, College of Medicine, Occupational and Environmental Medicine)
  • 김윤신 (한양대학교 의과대학 산업의학교실) ;
  • 노영만 (한양대학교 의과대학 산업의학교실) ;
  • 윤영훈 (한양대학교 의과대학 산업의학교실) ;
  • 이철민 (한양대학교 의과대학 산업의학교실) ;
  • 김기연 (한양대학교 의과대학 산업의학교실) ;
  • 김종철 (한양대학교 의과대학 산업의학교실) ;
  • 전형진 (한양대학교 의과대학 산업의학교실) ;
  • 심인숙 (한양대학교 의과대학 산업의학교실)
  • Published : 2007.12.17

Abstract

The goal of this study was to provide basic data for arrangement of management in museum environment. We investigated characteristics of distribution on indoor air pollutants at exhibition halls and storages in museums between July and August, 2007. The monitoring carried out at three cultural sites, Pusan, Daejeon and Kyungjoo which is possessed their own exhibition hall and storage in Museums. We adopt the several pollutants for this survey such as $PM_{10}$, $PM_{2.5}$ $CO_2$, Formaldehyde, TBC, CO, $NO_2$, Rn, VOCs, $O_3$ and followed the standard method of Ministry of Environment, Korea for sampling and analysis, respectively. The results of this survey revealed that average concentration of $PM_{10}$ and $PM_{2.5}$ in storages were $117.3{\mu}g/m^3$ and $92.6{\mu}g/m^3$, respectively. The average concentration in storages of gases pollutants and microorganism such as $CO_2$, Formaldehyde, $NO_2$, Rn, TVOC, $O_3$, and TBC showed as: 788.8ppm, $30.7{\mu}g/m^3$, 0.4ppm, 6.4ppb, $1.3pCi/{\ell}$, $1,374.9{\mu}g/m^3$, 2.4ppb, and $119.4cfu/m^3$, respectively. In addition, average concentration of $PM_{10}$ and $PM_{2.5}$ in exhibition halls were $49.5{\mu}g/m^3$ and $56.1{\mu}g/m^3$, respectively. The average concentration in exhibition halls of gases pollutants and microorganism such as $CO_2$, Formaldehyde, $NO_2$, Rn, TVOC, $O_3$, and TBC showed as: 475.2ppm, $94.1{\mu}g/m^3$, 0.3ppm, 12.4ppb, $0.3pCi/{\ell}$, $1,179.1{\mu}g/m^3$, 5.2ppb, 2.4ppb, and $24.8cfu/m^3$, respectively.

Keywords

Acknowledgement

Supported by : 국립문화재연구소