DOI QR코드

DOI QR Code

Best Measurement Capability and Standard Test Facility for the Water-level Gauges

수위계 표준시험장치 개발 및 최고측정능력에 관한 연구

  • 신강욱 (한국수자원공사 수자원연구원) ;
  • 홍성택 (한국수자원공사 수자원연구원)
  • Published : 2007.10.01

Abstract

Rain data and water-level data are importantly used for dam operation at flood period. Because dams are directly controlled by the water-level data, the characteristic of the water-level gauges is necessary to be managed. Thus, we developed the standard test facility and method for testing the water-level gauges which are a float type, a supersonic type and a radar type. And we calculated the uncertainty of the standard test facility to maintain the accuracy of water-level gauges. Through development of this facility, we could obtain the characteristics and the calibration factor of the water-level gauges. And, this study showed that the standard test facility can be widely used for dam operation and basin management.

Keywords

References

  1. 건설교통부, '수문관측매뉴얼,' 2004
  2. 신강욱, 홍성택, '질량측정에 의한 우량계 표준교정시스템 개발.' 제어.자동화.시스템공학 논문지,vol. 12, no. 8, pp. 818-823, 2006 https://doi.org/10.5302/J.ICROS.2006.12.8.818
  3. 한국수자원공사 '수자원기초자료 신뢰도 제고를 위한 수위계 및 우량계 검보정 방안 연구(1차년도.),' 2000
  4. 한국수자원공사 '수자원기초자료 신뢰도 제고를 위한 수위계 및 우량계 검보정 방안 연구(2차년도),' 2001
  5. Robert G. Skrentner, 'Instrumentation Handbook for water & wasterwater treatment plants,' Lewis Pub., 1988
  6. 한국교정시험기관인정기구, '측정불확도 추정사례집,' 2004
  7. 한국표준과학연구원, '불확도 평가 및 표현 사례집,' 2005
  8. 기술표준원, '국가교정기관 지정제도 운영세칙,' 2007

Cited by

  1. Development of Portable Calibration System for Non-Contact Water Meters vol.20, pp.9, 2016, https://doi.org/10.6109/jkiice.2016.20.9.1808
  2. Active Water-Level and Distance Measurement Algorithm using Light Beam Pattern vol.52, pp.4, 2015, https://doi.org/10.5573/ieie.2015.52.4.156