축방향 자기장 인가를 통한 플라즈마토치 전극 수명연장

Extension of Electrode Lifetime for Plasma Torch by Axial Magnetic Field

  • 발행 : 2007.11.01

초록

Axial magnetic field was applied into the hollow anode of plasma torch for the purpose of extension of electrode lifetime. The average arc voltage increased because the arc column became longer, the arc voltage ripple frequency became low. The steady state of arc voltage was removed by applied magnetic filed. The lifetime of electrode was 60 times longer than operation without magnetic field.

키워드

참고문헌

  1. N. Venkatramani, Current Science, 83, 254(2002)
  2. He-ping Li and E. Pfender, IEEE Trans. on Plasma Sci., 33, 400(2005) https://doi.org/10.1109/TPS.2005.844954
  3. A. R. dayal and R. T. Deam, J. Phys. D: Appl. Phys., 35 1486(2002)
  4. S. Ghorui, S. N. Sahasrabudhe, P. S. S. Murthy, A. K. Das, and N. Venkatramani, IEEE Trans. on Plasma Sci., 28, 2179(2000)
  5. Iean-Luc Dorier, MaIko Gindrat, Christoph Hollenstein, Armando Salito, Michael Loch, and Gerara Barbezat, IEEE Trans. on Plasma Sci., 29, 494(2001)