Abstract
The regular RC structures have been transformed into irregular RC structures by alternate load of RC structures during explosive demolition. Numerical simulation programs have contributed to a better understanding of large displacement collapse behavior during explosive demolition, but there remain a number of problems which need to be solved. In this study, the 1/5 scaled 1, 3 and 5 stories RC structures were designed and fabricated. To consider the collapse possibility of upper dead load, fabricated RC structures were demolished by means of felling method. To observe the collapse behavior of the RC structures during felling, displacement of X-direction (or horizontal), displacement of Z-direction (or vertical) md relative displacement angle from respective RC structures were analyzed. Finally explosive demolition on the scaled RC structures using felling method are carried out, collapse behavior by felling method is affected by upper dead load of scaled RC structures. Displacement of X and Z direction increases gradually to respective 67ms and 300ms after blasting. It is confirmed that initial collapse velocity due to alternate load has a higher 3 stories RC structures than 5 stories.
발파해체 되는 철근콘크리트 구조물은 교대하중에 의해 정형구조에서 비정형구조로 변환되며 붕괴거동은 비선형적인 대변위 거동을 한다. 철근콘크리트 구조물의 붕괴거동에 대한 많은 수치 모델링 연구가 수행되었지만, 비선형적인 대변위 거동을 해석하기에는 아직 부족한 수준이다. 본 연구에서는 실제 철근콘크리트 구조물을 1/5로 축소한 축소모형 구조물을 제작하였다. 전도공법으로 1층, 3층, 5층 축소모형 구조물을 발파하여 상부 자중에 의한 구조물의 붕괴 가능성을 고찰하였으며, 구조물의 붕괴거동을 X 방향(수평방향)의 변위, Z 방향(수직방향)의 변위, 상대 변위각으로 분석하였다. 실험결과 자중에 의한 구조물의 붕괴를 유도하기 위한 상부 자중의 크기를 확인할 수 있었다. 또한 구조물의 붕괴에 따른 X 방향의 변위와 Z방향의 변위는 발파 후 67 ms, 300 ms부터 서서히 증가하였고, 교대하중에 의해 3층 구조물의 초기 붕괴 속도가 5층 구조물보다 크게 발생하는 것을 확인하였다.