비스무스코팅 탄소섬유전극과 갤릭산 착물을 사용한 구리 이온의 흔적량 분석

Bismuth Coated Carbon Fiber Microelectrode with Gallic Acid n-Propyl Ester for Trace Copper Analysis

  • Ly, Suw-Young (Biosensor Research Institute, Seoul National University of Technology) ;
  • Lee, Chang-Hyun (Division of General Education, Pyeongtaek University) ;
  • Jung, Young-Sam (Department of Chemistry Korea University)
  • 발행 : 2007.10.31

초록

A bismuth-coated carbon fiber microelectrode was prepared using cyclic voltammetry (CV). An analytical application was performed for the copper analysis with Square Wave Stripping Voltammetry (SWSV). Gallic acid n-propyl ester (PG) was used for the complex formation with a copper ion, and electrochemical measurements were performed with a pre-amplifier of a low-current module for nano am per detection. The effects of various parameters on the response were optimized. Analytical working ranges of $0.03-25.9\;{\mu}gl^{-1}$ and $0-25\'mgl^{-1}$ Cu(II) were obtained. The relative standard deviation at $13\;mgl^{-1}$ Cu was 0.9% (n = 12) in optimum conditions. The detection limit was found to have been $0.019\;{\mu}gl^{-1}$, with a 30-sec accumulation time. The developed methods were applied to a copper assay in water samples.

키워드

참고문헌

  1. Prakash R., Srivastava R. C., Seth P. K., 2002, Estimation of copper in natural water and blood using anodic stripping differential pulse voltammetry over a rotating side disk electrode, Electroanalysis, 14, 303-308 https://doi.org/10.1002/1521-4109(200202)14:4<303::AID-ELAN303>3.0.CO;2-T
  2. Bagshaw A. P., Farquharson., Michael J., 2002, Simultaneous determination of iron, copper and zinc concentrations in skin phantoms using XRF spectrometry, X-Ray Spectrometry, 31(1), 47-52 https://doi.org/10.1002/xrs.535
  3. Wang J., Serra B., Ly S.Y., Lu J., Pingarron J. M., 2001, Determination of micromolar bromate concentrations by adsorptive-catalytic stripping veltammetry of the molybdenum-3-methoxy-4-hydroxymandelic acid complex, Talanta, 54(1), 147-151 https://doi.org/10.1016/S0039-9140(00)00646-9
  4. Khoo S. B., Guo S. X., 1999, Rapidly renewable and reproducible electropolymerized surface at a monomer modified carbon paste electrode, Journal of Electroanalytical Chemistry, 465(1), 102-113 https://doi.org/10.1016/S0022-0728(99)00066-2
  5. Zhongmin H., Carl J. S., William R. H., 1998, PAN-incorporated Nafion-modified spectroscopic graphite electrodes, Analytica Chimica Acta, 369, 93 https://doi.org/10.1016/S0003-2670(98)00203-7
  6. Azza M. M. A., Othman A. F., Mahmoud. A. G., 2000, Determination of thiopentone sodium in aqueous and biological media by cathodic stripping voltammetry, Analytica Chimica Acta, 412, 99 https://doi.org/10.1016/S0003-2670(00)00770-4
  7. Ghoneim M. M., Mabrouk M. M., Hassanein A. M., Tawfik A., 2001, Polarographic behavior of loratadine and its direct determination in pharmaceutical formulation and human plasma by cathodic adsorptive stripping voltammetry, Journal of Pharmaceutical and Biomedical Analysis, 25(5-6), 933-939 https://doi.org/10.1016/S0731-7085(01)00384-3
  8. Locatelli C., Torsi G., 1999, Cathodic and anodic stripping voltammetry: simultaneous determination of As-Se and Cu-Pb-Cd-Zn in the case of very high concentration ratios, Talanta, 50(5), 1079-1088 https://doi.org/10.1016/S0039-9140(99)00213-1
  9. Pournaghi-Azar M. H., Ramazani M. R., 2002, Selective determination of trace copper by extraction-anodic stripping voltammetry of copper(II) acetylacetonate in nonaqueous media, Electroanalysis, 14(17), 1203-1208 https://doi.org/10.1002/1521-4109(200209)14:17<1203::AID-ELAN1203>3.0.CO;2-9
  10. Frey H -H., McNeil C. J., Keay R. W., Bannister J. V., 1998, Characterization of a copper detecting amperometric electrode, Electroanalysis, 10(7), 480-485 https://doi.org/10.1002/(SICI)1521-4109(199806)10:7<480::AID-ELAN480>3.0.CO;2-F
  11. Zolezzi S., Spodine E., Decinti A., 2002, Electrochemical studies of copper(II) complexes with Schiff-base ligands, Polyhedron, 21 (1), 55-59 https://doi.org/10.1016/S0277-5387(01)00960-3
  12. Staden J. F., Matoetoe M. C., 2000, Simultaneous determination of copper, lead, cadmium and zinc using differential pulse anodic stripping voltammetry in a flow system, Analytica Chimica Acta, 411, 201 https://doi.org/10.1016/S0003-2670(00)00785-6
  13. Yang W., Gooding J. J., Hibbert D. B., 2001, Characterization of gold electrodes modified with self-assembled monolayers of I-cysteine for the adsorptive stripping analysis of copper, Journal of Electroanalytical Chemistry, 516(1-2), 10-16 https://doi.org/10.1016/S0022-0728(01)00687-8
  14. Ortiz Viana M. M., Agraz R., Procopio J. R., Sevilla M. T., Hernandez L., 1999, Comparison of two kinetic approaches for copper speciation using ion-exchange columns and ion-exchange modified carbon paste electrodes, Analytica Chimica Acta, 382(1-2), 179-188 https://doi.org/10.1016/S0003-2670(98)00830-7
  15. Khoo S. B., Guo S. X., 1999, Rapidly renewable and reproducible electropolymerized surface at a monomer modified carbon paste electrode, Journal of Electroanalytical Chemistry, 465(1), 102-113 https://doi.org/10.1016/S0022-0728(99)00066-2
  16. Alemu H., Chandravanshi B. S., 1998, Differential pulse anodic stripping voltammetric determination of copper(II) with N-phenylcinnamohydroxamic acid modified carbon paste electrodes, Analytica Chimica Acta, 368, 165 https://doi.org/10.1016/S0003-2670(98)00019-1
  17. Etienne M., Bessiere J., Walcarius A., 2001, Voltammetric detection of copper(II) at a carbon paste electrode containing an organically modified silica, Sensors and Actuators, B: Chemical, B76 (1-3), 531-538
  18. Arvinte A., Valentini F., Radoi A., Arduini F., Tamburri E., Rotariu L., Palleschi G., Bala C., 2007, The NADH electrochemical detection performed at carbon nanofibers modified glassy carbon electrode. Electroanalysis, 19(14), 1455-1459 https://doi.org/10.1002/elan.200703879
  19. Marken F., Gerrard M. L., Mellor I. M., Mortimer R. J., Madden C. E., Fletcher S., Holt K., Foard J. S., Dahm R. H., Page F., 2001, Voltammetry at carbon nanofiber electrodes. Electrochemistry Communications, 3(4), 177-180 https://doi.org/10.1016/S1388-2481(01)00132-1
  20. Zhang X., Ogorevc B., Rupnik M., Kreft M., Zorec R.,1999, Cathophoresis paint insulated carbon fiber ultramicro disc electrode and its application to in vivo amperometric monitoring of quantal secretion from single rat melanotrophs., Analytica Chimica Acta, 378, 135 https://doi.org/10.1016/S0003-2670(98)00570-4
  21. Huebra M. G., Pedro H., Yolanda B., 2001, Determination of linuron in soil by stripping voltammetry with a carbon fiber microelectrode, Talanta, 54(6), 1077-1085 https://doi.org/10.1016/S0039-9140(01)00372-1
  22. Ly S. Y., Kim Y. H., Han I. K., Moon I. G., Jung W. W., Jung S. Y., Sin H.J., Hong T. K., Kim M. H., 2006, Anodic square-wave stripping voltammetric analysis of epinephrine using carbon fiber microelectrode, Microchemical Journal, 82(1),113-118 https://doi.org/10.1016/j.microc.2005.12.002
  23. Marken F., Gerrard M. L., Mellor I. M., Mortimer R. J., Madden C. E., Fletcher S., Holt K., Foord J. S., Dahm R. H., Page F., 2001, Voltammetry at carbon nanofiber electrodes, Electrochemistry Communications, 3(4), 177-180 https://doi.org/10.1016/S1388-2481(01)00132-1
  24. Wo J. T., Huang Y., Zhou J. Z., Luo J., Lin Z. H., 1997, Electrochemical behaviors of DNA at mercury film electrode, Bioelectrochemistry and Bioenergetics, 44, 151 https://doi.org/10.1016/S0302-4598(97)00049-4
  25. Jenny G., Pascal S., Constant M. G., Van D. B., 2006, Advantages of using a mercury coated, micro-wire, electrode in adsorptive cathodic stripping voltammetry, Analytica Chimica Acta, 571, 86-92 https://doi.org/10.1016/j.aca.2006.04.043
  26. Zakharchuk N. F., Brainina K. Z., 1998, The surface morphology of mercury plated glassy-carbon electrodes and stripping voltammetry of heavy metals, Electroanalysis, 10(6), 379-386 https://doi.org/10.1002/(SICI)1521-4109(199805)10:6<379::AID-ELAN379>3.0.CO;2-S
  27. Ly S. Y., Kim D. H., Kim M. H., 2002, Squarewave cathodic stripping voltammetric analysis of RDX using mercury-film plated glassy carbon electrode, Talanta (2002), 58(5), 919-926 https://doi.org/10.1016/S0039-9140(02)00442-3
  28. Hocevar S. B., Ogorevc B., Wang J., Pihlar B., 2002, A study on operational parameters for advanced use of bismuth film electrode in anodic stripping voltammetry, Electroanalysis, 14(24), 1707-1712 https://doi.org/10.1002/elan.200290014
  29. Wang J., Lu J., 2000, Bismuth film electrodes for adsorptive stripping voltammetry of trace nickel, Electrochemistry Communications, 2(6), 390-393 https://doi.org/10.1016/S1388-2481(00)00045-X
  30. Wang J., Deo R. P., Thongngamdee S., Ogorevc B., 2001, Effect of surface-active compounds on the stripping voltammetric response of bismuth film electrodes, Electroanalysis, 13(14), 1153-1156 https://doi.org/10.1002/1521-4109(200110)13:14<1153::AID-ELAN1153>3.0.CO;2-I
  31. Flechsig G. V., Korbout O., Hocevar S. B., Thongngamdee S., Ogorevc B., Grundler P., Wang J., 2002, Electrically heated bismuth-film electrode for voltammetric stripping measurements of trace metals, Electroanalysis, 14(3), 192-196 https://doi.org/10.1002/1521-4109(200202)14:3<192::AID-ELAN192>3.0.CO;2-6
  32. Hocevar S. B., Wang J., Deo R. P., Ogorevc B., 2002, Potentiometric stripping analysis at bismuth-film electrode, Electroanalysis, 14(2), 112-115 https://doi.org/10.1002/1521-4109(200201)14:2<112::AID-ELAN112>3.0.CO;2-5
  33. Ye X., Yang Q., Yan W., Li N., 1998, Electrochemical behavior of gold, silver, platinum and palladium on glassy carbon electrode modified by chitosan and its application, Talanta, 47(5), 1099-1106 https://doi.org/10.1016/S0039-9140(98)00189-1
  34. Bai, Ruan X., Mo J., Xie Y., 1998, Potentiometric stripping determination of copper using cysteine modified mercury film electrode, Analytica Chimica Acta, 373(1), 39-46 https://doi.org/10.1016/S0003-2670(98)00361-4
  35. Yang H. Y., Sun I. W., 1998, Cathodic stripping voltammetric determination of tellurium(IV) at a Nafion/8-quinolinol mercury film modified electrode, Analytica Chimica Acta, 358(3), 285-290 https://doi.org/10.1016/S0003-2670(97)00640-5
  36. Sander S., Wagner W., Henze G., 1995, Direct determination of uranium traces by adsorptive stripping voltammetry, Analytica Chimica Acta, 305(1-3), 154-8 https://doi.org/10.1016/0003-2670(95)90135-3
  37. Bastos M. B. R., Moreira J. C., Farias P. A. M., 2000, Adsorptive stripping voltammetric behavior of U02(Il) complex with Schiff base N,N'-ethyl-enebis(salicylidenimine) in aqueous medium containing 4-(2-hydroxyethyl)-I-piperazine ethanesulfonic acid, Analytica Chimica Acta, 408(1-2), 83-88 https://doi.org/10.1016/S0003-2670(99)00865-X
  38. Pretty J. R., Van B., Gary J., Duckworth D. C.,1998, Adsorptive stripping voltammetry as a sample pretreatment method for trace uranium determinations by inductively coupled plasma mass spectrometry, International Journal of Mass Spectrometry, 178(1/2), 51-63 https://doi.org/10.1016/S1387-3806(98)80001-8
  39. Sander S., 1999, Simultaneous adsorptive stripping voltammetric determination of molybdenum (VI), uranium(VI), vanadium(V), and antimony (III), Analytica Chimica Acta, 394(1), 81-89 https://doi.org/10.1016/S0003-2670(99)00218-4
  40. Safavi A., Maleki N., Shams E., Shahbaazi H. R., 2002, Determination of copper by adsorptive stripping voltammetry of its complex with adenine. Chemistry Department, Electroanalysis, 14(13), 929-934 https://doi.org/10.1002/1521-4109(200207)14:13<929::AID-ELAN929>3.0.CO;2-W
  41. Wang, J., Lu J., Wang J., Luo D., Tian B., 1997, Simultaneous measurements of trace chromium and uranium using mixed ligand adsorptive stripping analysis Department of Chemistry and Biochemistry, Analytica Chimica Acta, 354(1-3), 275-281 https://doi.org/10.1016/S0003-2670(97)00454-6