펌프 흡수정내 발생된 보텍스에 대한 CFD 예측

CFD Prediction on Vortex in Sump Intake at Pump Station

  • 발행 : 2007.08.01

초록

In large pump station, vortex generation such as free-surface vortex and submerged vortex occurring around pump intake, or at bell-mouth inlet has been an important flow characteristics which should be considered always to keep away the suction of air-entrained or cavitated flow. In this study, a commercial CFD code was used to predict accurately the vortex generation for the specified intake design. These result shows the preliminary result of submerged vortex prediction for the Turbo-machinery Society of Japan Sump Test CFD standard model. At bottom wall, air volume fraction (red color) was found in a large scale to explain the submerged vortex generation at particular operation and configuration condition. And these indicate the free surface formation behind the bell mouth. Particularly, non-uniform approaching flow is a major parameter to govern the occurrence of the free-surface vortex. Futhermore the comparison between turbulence ($k-{\epsilon}$ & $k-{\omega}$ model) mode were executed in this study.

키워드

참고문헌

  1. Ryuichiro IWANO, Takanori Shibata, Takahide Nagahara, Tomoyoshi Okamura, 'Numerical Prediction Method of a Submerged Vortex and its Application to the flow in Pump Sumps with and without a baffle plate,' The 9th if International Symposium on Transport Phenomena and Dynamic of Rotating Machinery, 2002
  2. Standard Method for Model Testing the Performance of a Pump Sump, TSJ, 2005
  3. HI Centrifugal Pump and Application, 1994
  4. Veera P. Rajendran, G. S. Constantinescu, and V. C. Patel, 'Experiments on Flow in a Model Water-Pump Intake Sump to Validate a Numerical Model,' Proc. of FEDSM'98, 1998 ASME Fluids Engineering Division Summer Meeting, (1998), CD-Rom
  5. 최종웅, 김정환, 남청도, 김유택, 이영호, 'PIV에 의한 흡입수조내 흡입관 주위의 유동특성에 관한 연구,' 대한기계학회 2001년도 추계학술대회논문집 B(2001), pp. 563-569
  6. M. Padmanabhan and G. E. Hecker, 'Scale Effects in Pump Sump Models,' J. of Hydraulic Engineering, Vol. 110, No. 11(1984), pp. 1540- 1556 https://doi.org/10.1061/(ASCE)0733-9429(1984)110:11(1540)
  7. G. S. Constantinescu and V. C. Patel, 'Numerical Model for Simulation of Pump-Intake Flow and Vortices,' J. of Hydraulic Engineering, Vol. 124, No. 2(1998), pp. 123-134 https://doi.org/10.1061/(ASCE)0733-9429(1998)124:2(123)
  8. ANSYS-CFX10 Manual, ANSYS

피인용 문헌

  1. Numerical analysis of the effects of anti-vortex device height on hydraulic performance of pump sump vol.21, pp.4, 2017, https://doi.org/10.1007/s12205-016-0714-z
  2. Effective Height of a Floor Splitter Anti-Vortex Device under Varying Flow Conditions vol.9, pp.2, 2017, https://doi.org/10.3390/su9020285