Abstract
Output voltage waves of a DC/AC inverter system are likely to be distorted if variable loads e.g. motors or rectifiers exist in the output terminal. This paper designs a disturbance observer-based PI-controller for a single-phase inverter system that is robust against load changes. In this Paper, we regard the output voltage changes due to various loads as disturbances of the control system. Then we design a disturbance observer for estimation of the disturbances caused by the load current and any other error sources (such as parameter uncertainties and model mismatches etc.). In order to test the performance of the proposed control law, simulation studies are carried out for a single-phase inverter system using SimPowerSystem of Matlab Simuink. Compared to a simple PI-control, the disturbance observer-based controller shows enhanced performance in transient responses for step load changes.
본 논문에서는 광범위하게 적용되고 있는 단상 인버터 시스템에 대한 강인성을 향상시키기 위해 외란관측기 기반의 PI-제어기 설계 방법을 제안한다. 출력 단에 모터나 정류기와 같은 가변부하가 존재할 경우, 인버터의 출력 전압은 변동하기 쉬우며 바람직하지 않은 과도현상을 보일 수 있다. 본 논문에서는 가변부하에 의해 발생하는 출력 전압의 변화를 시스템의 외란에 의한 결과를 간주하여 부하 전류와 시스템의 불학실성에 의한 오차 (파라미터 변화나 잘못된 모델링과 같은)를 보상하는 외란관측기 기반 제어기를 설계한다. Matlab Simuink의 SimPowerSystem을 이용하여 단상 인버터 시스템에 대한 외란관측기 기반 제어기의 성능을 입증한다.