대한디지털의료영상학회논문지 (Korean Journal of Digital Imaging in Medicine)
- 제9권2호
- /
- Pages.39-43
- /
- 2007
- /
- 1976-7641(pISSN)
혈관조영술에서 동영상 전송의 유용성 고찰
Continued image Sending in DICOM of usefulness Cosideration in Angiography
- 박용성 (경희대학교 동서신의학병원 영상의학과) ;
- 이종웅 (경희대학교 동서신의학병원 영상의학과) ;
- 정희동 (경희대학교 동서신의학병원 영상의학과) ;
- 김재열 (경희대학교 동서신의학병원 영상의학과) ;
- 황선광 (경희대학교 동서신의학병원 영상의학과)
- Park, Young-Sung (Department of Radiology, East-West Neoo Medical Center, Kyung Hee University) ;
- Lee, Jong-Woong (Department of Radiology, East-West Neoo Medical Center, Kyung Hee University) ;
- Jung, Hee-Dong (Department of Radiology, East-West Neoo Medical Center, Kyung Hee University) ;
- Kim, Jae-Yeul (Department of Radiology, East-West Neoo Medical Center, Kyung Hee University) ;
- Hwang, Sun-Gwang (Department of Radiology, East-West Neoo Medical Center, Kyung Hee University)
- 발행 : 2007.12.30
초록
In angiography, the global standard agreements of DICOM is lossless. But it brings on overload and takes too much store space in DICOM sever. Because of all those things we transmit images which is classified in subjective way. But this cause data loss and would be lead doctors to make wrong reading. As a result of that we try to transmit continued image (raw data) to reduce those mistakes. We got angiography images from the equipment(Allura FD20-Philips). And compressed it in two different methods(lossless & lossy fair). and then transmitted them to PACS system. We compared the quality of QC phantom images that are compressed by different compress method and compared spatial resolution of each images after CD copy. Then compared each Image's data volume(lossless & lossy fair). We measured spatial resolution of each image. All of them had indicated 401p/mm. We measured spatial resolution of each image after CD copy. We got also same conclusion (401p/mm). The volume of continued image (raw data) was 127.8MB(360.5 sheets on average) compressed in lossless and 29.5MB(360.5 sheets) compressed in lossy fair. In case of classified image, it was 47.35MB(133.7 sheets) in lossless and 4.5MB(133.7 sheets) in lossy fair. In case of angiography the diagnosis is based on continued image(raw data). But we transmit classified image. Because transmitting continued image causes some problems in PACS system especially transmission and store field. We transmit classified image compressed in lossless But it is subjective and would be different depend on radiologist. therefore it would make doctors do wrong reading when patients transfer another hospital. So we suggest that transmit continued image(raw data) compressed in lossy fair. It reduces about 60% of data volume compared with classified image. And the image quality is same after CD copy.