Abstract
Flexural design of double composite box girder over the interior pier for three-span continuous bridge was performed by the LRFD method. The maximum span length of the continuous bridge ranged from 80m to 120m and the relative ratio of the span length was assumed to be 1:1.25:1. The girder section was designed for the strength limit state and service limit state with additional design check for constructibility. Before the bottom concrete and compression flange showed a complete composite action, the buckling of lower compression flange was checked. The flexural stiffness and flexural resistance characteristics for the section and for the constituent members such as tension flange, compression flange, and web were analyzed for different thicknesses of the bottom concrete on top of the compression flange. The effect of the distribution ratio of steel between the top and bottom flanges was investigated by analyzing ductility behavior and stress distribution through the girder's depth for several different relative area ratios of steel between the top and bottom flanges. It was found that a total amount of 15% of steel can be saved by applying the double composite system compared with that of the conventional composite system.
LRFD 법을 이용하여 3경간 연속 이중합성 박스거더교의 부모멘트를 받는 내측 교각 위 단면을 설계하였다. 3경간 연속교의 최대경간은 80-120m를 고려하였으며 경간비는 1:1.25:1로 가정하였다. 설계 시에는 최대부모멘트를 받는 이중합성거더 단면의 강도한계상태, 사용성한계상태 및 시공성 검토를 고려하였다. 하부 보강콘크리트가 압축플랜지에 합성되기 전에는 압축플랜지의 좌굴을 검토하였으며 합성 후에는 좌굴이 방지된 것으로 가정하였다. 이중합성 박스거더의 하부플랜지 위에 타설하는 콘크리트의 두께에 따른 단면전체의 휨강성과 휨저항강도를 비롯하여 인장플랜지, 압축플랜지 및 복부판의 휨강도를 비교 분석하였다. 상부플랜지와 하부플랜지 단면적비가 이중합성 박스거더의 연성거동 및 휨응력 분포에 미치는 영향을 검토하고 적절한 단면적비를 분석하였다. 하부 보강콘크리트의 유무에 따른 소요 강재량을 비교한 결과, 이중합성 거더의 경우가 기존 단일합성 거더에 비해 15% 내외의 강재량 절감효과가 있는 것으로 분석되었다.