A new steel connection method using wedges known as Self-Locking Connector has been developed. In this study, experimental investigation was conducted to verify the seismic performance of steel beam-to-column joints with Self-Locking Connectors. Cyclic-loading tests were performed on two beam-to-column joints with Self-Locking Connectors. The two beam-to-column joint specimens were of the cantilever-type and had the same details. Test results showed that beam-to-column joints with Self-Locking Connectors were able to developa total rotation capacity of 0.06 radian, which is greater than the 0.04 radian required for Special Moment Frames. Moreover, their energy absorption capacity was much greater than that of conventional joints.

강재의 접합형식으로 쐐기의 원리를 이용한 새로운 접합장치인 쐐기형 접합장치(wedge connectors)가 개발되었다. 본 연구에서는 새로운 접합장치를 적용한 철골 보-기둥 접합부의 내진성능에 대한 실험연구를 수행하였다. 새로운 접합장치를 적용한 2개의 보-기둥 접합부 시험체에 대해 반복하중 실험을 수행하였다. 2개의 시험체는 켄티레버형이며 동일한 상세를 갖도록 제작되었다. 반복하중 실험의 결과 2개의 시험체 모두 특수모멘트골조에 대해 요구되는 총회전각인 0.04 라디안보다 큰 0.06라디안의 총회전각을 발휘할 수 있었으며 기존의 보-기둥 접합형식에 비해 에너지 소산능력이 크게 우수한 것으로 나타났다.

Keywords

References

  1. 박종원. (2006). 정역학, 명현출판사. pp. 339-346
  2. 오상훈, 김영주, 유홍식, 강창훈. (2006). '보의 하부 플랜지 에 에너지 흡수요소를 가지는 기둥-보 접합부의 이력특 성.' 대한건축학회, 제 22권 8호, pp. 29-36
  3. AISC (2005). Seismic Provisions for Structural Steel Buildings. American Institute of Steel Construction, Chicago, Illinois
  4. Bertero, V.V.,; Anderson, J. C.,; and Krawinkler, H. (1994), Performance of Steel Building Structures during the Northridge Earthquake, Report No. UCB/EERC-94/09, Berkeley: Earthquake Engineering Research Center, Univ. of California
  5. Jones, S. L., Fry, G. T., and Engelhardt, M. D. (2002). Experimental evaluation of cyclically loaded reduced beam section connections. J. Struct. Eng., 128(4), 441-451 https://doi.org/10.1061/(ASCE)0733-9445(2002)128:4(441)
  6. Kim, T., Whittacker, M., Gilani, M. Bertero, M. and Takhirov, A. M. (2002). Experimental evaluation of plate-reinforced steel moment- resisting connections. Journal of Structural Engineering, ASCE, 128(4), pp. 483-491 https://doi.org/10.1061/(ASCE)0733-9445(2002)128:4(483)
  7. Lee, C. H., Jeon, S. W., Kim, J. H., and Uang, C. M. (2005). Effects of panel zone strength and beam web connection method on seismic performance of reduced beam section steel moment connections. Journal of Structural Engineering, ASCE, 131(12), pp. 1854-1865 https://doi.org/10.1061/(ASCE)0733-9445(2005)131:12(1854)
  8. Nakashima, M., Saburi, K., Tada, M. (1998), 'Classification of Damage to Steel Buildings Observed in the 1995 Hyogoken- Nanbu Earthquake, J. Engrg. Struct., 20(46), pp. 271-281 https://doi.org/10.1016/S0141-0296(97)00019-9
  9. Park, J. W., and Hwang, I. K. (2003). Experimental Investigation of Reduced Beam Section Connections by Use of Web Openings, Engineering Journal, AISC, Vol. 40, N0. 2, pp. 77-88
  10. Park, J. W., and Hwang, I. K. (2006). Development of a New Steel Connection, Steel Structures, Vol. 6, N0. 3, pp. 209-213
  11. SAC (2000), Seismic Design Criteria for New Moment Resisting Steel Frame Construction, Rep. No. FEMA-350, SAC Joint Venture, Sacramento. Calif
  12. Summer, E. A. and Murray, T. M. (2002). Behavior of extended end-plate moment connections subjected to cyclic loading. Journal of Structural Engineering, ASCE, 128(4), pp. 501-508 https://doi.org/10.1061/(ASCE)0733-9445(2002)128:4(501)