DOI QR코드

DOI QR Code

Estimation Method for Brain Activities are Influenced by Blood Pulsation Effect

Blood Pulsation의 효과가 뇌 활성화에 미치는 영향을 알아보는 방법

  • Lee, W.H. (Department of Biomedical Engineering, Hanyang University) ;
  • Ku, J.H. (Department of Biomedical Engineering, Hanyang University) ;
  • Lee, H.R. (Department of Biomedical Engineering, Hanyang University) ;
  • Han, K.W. (Department of Biomedical Engineering, Hanyang University) ;
  • Park, J.S. (Department of Biomedical Engineering, Hanyang University) ;
  • Kim, J.J. (Institute of Behavioral Science in Medicine, Yonsei University Severance Mental Health Hospital) ;
  • Yoon, K.J. (St.Peter's Hospital) ;
  • Kim, I.Y. (Department of Biomedical Engineering, Hanyang University) ;
  • Kim, S.I. (Department of Biomedical Engineering, Hanyang University)
  • 이원호 (한양대학교 의용생체공학과) ;
  • 구정훈 (한양대학교 의용생체공학과) ;
  • 이형래 (한양대학교 의용생체공학과) ;
  • 한기완 (한양대학교 의용생체공학과) ;
  • 박진식 (한양대학교 의용생체공학과) ;
  • 김재진 (연세대학교 정신건강병원 행동과학 연구실) ;
  • 윤강준 (강남 베드로 병원) ;
  • 김인영 (한양대학교 의용생체공학과) ;
  • 김선일 (한양대학교 의용생체공학과)
  • Published : 2007.06.30

Abstract

BOLD T2*-weighted MR images reflects cortical blood flow and oxygenation alterations. fMRI study relies on the detection of localized changes in BOLD signal intensity. Since fMRI measures the very small modulations in BOLD signal intensity that occur during changes in brain activity, it is also very sensitive to small signal intensity variations caused by physiologic noise during the scan. Due to the complexity of movement of various organs associated with heart beat, it is important to reduce cardiac related noise rather than other physiological noise which could be required with relatively simple method. Therefore, a number of methods have been developed for the estimation and reduction of cardiac noise in fMRI study. But, each method has limitation. In this study, we proposed a new estimation method for brain activities influenced by blood pulsation effect using regression analysis with blood pulsation signal and the correspond slice of fMRI. We could find out that the right anterior cingulate cortex and right olfactory cortex and left olfactory cortex were largely influenced by blood pulsation effect for new method. These observed areas are mostly on the structure of anterior cerebral artery in the brain. That is convinced with that our method would be valid and our new method is easier to apply in practice and reduce computational burden than the retrospective method.

Keywords

References

  1. Ogawa S, Tank DW, Menon R, Ellermann JM, Kim SG, Merkle H and Ugurbil K, 'Intrinsic signal changes accompanying sensory stimulation: functional brain mapping with magnetic resonance imaging,' in Proc. the National Academy of Sciences of the United States of America, 1992, vol. 89, no. 13, pp.5951-5955
  2. Fox PT and Raichle ME, 'Focal physiological uncoupling of cerebral blood flow and oxidative metabolism during somatosensory stimulation in human subjects,' in Proc. the National Academy of Sciences of the United States of America, 1986, vol. 83, no. 4, pp.1140-1144
  3. Frahm J, Bruhn H, Merboldt KD and Hanicke W, 'Dynamic MR imaging of human brain oxygenation during rest and photic stimulation,' J. Magn. Reson. Imaging., vol. 2, no. 5, pp.501-505, 1992 https://doi.org/10.1002/jmri.1880020505
  4. Aguirre GK, Zarahn E and D'Esposito M, 'The variability of human, BOLD hemodynamic responses,' NeuroImage. vol. 8, no. 4, pp.360-369, 1998 https://doi.org/10.1006/nimg.1998.0369
  5. Hu X, Le TH, Parrish T and Erhard P, 'Retrospective estimation and correction of physiological fluctuation in functional MRI,' Magn. Reson. Med., vol. 34, no. 2, pp.201-212, 1995 https://doi.org/10.1002/mrm.1910340211
  6. Friston KJ, Williams S, Howard R, Frackowiak RS and Tumer R, 'Movement-related effects in fMRI time-series,' Magn. Reson. Med., vol. 35, no. 3, pp.346-355, 1996 https://doi.org/10.1002/mrm.1910350312
  7. Hajnal JV, Myers R, Oatridge A, Schwieso JE, Young IR and Bydder GM, 'Artifacts due to stimulus correlated motion in functional imaging of the brain,' Magn. Reson. Med., vol. 31, no. 3, pp.283-291, 1994 https://doi.org/10.1002/mrm.1910310307
  8. Jiang T, He Y, Zang Y and Weng X, 'Modulation of functional connectivity during the resting state and the motor task,' Human brain mapping., vol. 22, no. 1, pp.63-71, 2004 https://doi.org/10.1002/hbm.20012
  9. Dagli MS, Ingeholm JE and Haxby JV, 'Localization of cardiac-induced signal change in fMRI,' NeuroImage, vol. 9, no. 4, pp.407-415, 1999 https://doi.org/10.1006/nimg.1998.0424
  10. Barry RL and Menon RS, 'Modeling and suppression of respiration-related physiological noise in echo-planar functional magnetic resonance imaging using global and one-dimensional navigator echo correction,' Magn. Reson. Med., vol. 54, no. 2, pp.411-418, 2005 https://doi.org/10.1002/mrm.20591
  11. Woods RP, Grafton ST, Holmes CJ, Cherry SR and Mazziotta JC, 'Automated image registration: I. General methods and intrasubject, intramodality validation,' Journal of computer assisted tomography, vol. 22, no. 1, pp.139-152, 1998 https://doi.org/10.1097/00004728-199801000-00027
  12. Ostuni JL, Levin RL, Frank JA and DeCarli C, 'Correspondence of closest gradient voxels--a robust registration algorithm,' J. Magn. Reson. Imaging., vol. 7, no. 2, pp.410-415, 1997 https://doi.org/10.1002/jmri.1880070227
  13. Biswal B, DeYoe AE and Hyde JS, 'Reduction of physiological fluctuations in fMRI using digital filters,' Magn. Reson. Med., vol. 35, no. 1, pp.107-113, 1996 https://doi.org/10.1002/mrm.1910350114
  14. Deckers RH, van Gelderen P, Ries M, Barret O, Duyn JH, Ikonomidou VN, Fukunaga M, Glover GH and de Zwart JA, 'An adaptive filter for suppression of cardiac and respiratory noise in MRI time series data,' NeuroImage, vol. 33, no. 4, pp.1072-1081, 2006 https://doi.org/10.1016/j.neuroimage.2006.08.006
  15. Glover GH, Li TQ and Ress D, 'Image-based method for retrospective correction of physiological motion effects in fMRI: RETROICOR,' Magn. Reson. Med., vol. 44, no. 1, pp.162-167, 2000 https://doi.org/10.1002/1522-2594(200007)44:1<162::AID-MRM23>3.0.CO;2-E
  16. Pfeuffer J, Van de Moorte1e PF, Ugurbil K, Hu X and Glover GH, 'Correction of physiologically induced global off-resonance effects in dynamic echo-planar and spiral functional imaging,' Magn. Reson. Med., vol. 47, no. 2, pp.344-353, 2002 https://doi.org/10.1002/mrm.10065
  17. Hu X and S.-G.Kim, 'Reduction of physiological noise in functional MRI using Navigator Echo,' Magn. Reson. Med., vol. 31, pp.495-503, 1994 https://doi.org/10.1002/mrm.1910310505
  18. Cox R, 'AFNI: software for analysis and visualization of functional magnetic resonance neuroimages,' Comput. Biomed. Res., vol. 29, no. 3, pp.163-173, 1996
  19. Foo JY and Wilson SJ, 'A computational system to optimise noise rejection in photoplethysmography signals during motion or poor perfusion states,' Medical & Biological Engineering & Computing, vol. 44, no. 1-2, pp.140-145, 2006 https://doi.org/10.1007/s11517-005-0008-y
  20. http://anatomy.yonsei.ac.kr/scripts/home/book_view.idc?name=CH4-PT1-TB1
  21. Feinberg DA and Mark AS, 'Human brain motion and cerebrospinal fluid circulation demonstrated with MR velocity imaging,' Radiology, vol. 163, no. 3, pp.793-799, 1987 https://doi.org/10.1148/radiology.163.3.3575734
  22. Greitz D, 'Cerebrospinal fluid circulation and associated intracranial dynamics. A radiologic investigation using MR imaging and radionuclide cisternography,' Acta radiologica. vol. 386, pp.1-23, 1993
  23. A.C. Burton, Physiology and Biophysics of Circulation, Year book Medical Publishers, 1971
  24. K. Shelley and S. Shelley, Clinical Monitoring, Saunders, 2001, pp. 420-428