References
- Taylor TD. Prosthodontic problems and limitations associated with osseointegration. J Prosthet Dent 1998:79:74-78 https://doi.org/10.1016/S0022-3913(98)70197-0
- Jemt T, Pettersson P. A 3-year follow-up study on single implant treatment. J Dent 1993:21:203-208 https://doi.org/10.1016/0300-5712(93)90127-C
- Goodacre CJ, Bernal G, Rungcharassaeng K, Kan JYK. Clinical complications with implants and implant prostheses. J Prosthet Dent 2003:90:121-132 https://doi.org/10.1016/S0022-3913(03)00212-9
- Binon PP, Sutter F, Beaty K, Brunski J, Gulbransen H, Weiner R. The role of screws in implant systems. Int J Oral Maxillofac Implants (supplement) 1994:9:8-63
- Haack JE, Sakaguchi RL, Sun T, Coffey JP. Elongation and preload stress in dental implant abutment screws. Int J Oral Maxillofac implants 1995: 10:529-536
- Motosh N. Development of design charts for bolts preloaded up to the plastic range. J Eng Ind 1976:98:849-851 https://doi.org/10.1115/1.3439041
- Martin WC, Woody RD, Miller BM, Miller AW. Implant abutment screw rorations and preloads for four different screw materials and surfaces. J Prosthet Dent 2001:86:24-32 https://doi.org/10.1067/mpr.2001.116230
- Drago CJ. A clinical study of the efficacy of goldtite square abutment screws in cement-retained implant restorations. Int J Oral Maxillofac Implants 2003: 18:273-278
- Mezger PR, Creugers NH. Titanium nitride coatings in clinical dentistry. J Dent 1992:20:342-344 https://doi.org/10.1016/0300-5712(92)90021-4
- Scarano A, Piattelli M, Vrespa G, Petrone G, Iezzi G, Piattelli A. Bone healing around titanium and titanium nitride-coated dental implants with three surfaces: an experimental study in rats. Clin Implant Dent Relat Res 2003:5:103-111 https://doi.org/10.1111/j.1708-8208.2003.tb00191.x
- Scarano A, Piattelli M, Vrespa G, Caputi S, Piattelli A. Bacterial adhesion on titanium nitride-coated and uncoated im plants: an in vivo human study. J OrallmplantoI 2003:29:80-85
- O' Brien WJ. Dental Materials and Their selection. 2nd ed. 1997:16-17
- Jeong YT, Chung CH, Lee HT. Screw joit stability according to abutment screw materials. J Korean Acad Prosthodont 2001 :39:297-305
- Park CI, Choe HC, Chung CH. Effect of surface coating on the screw loosening of dental abutment screws. Metal Materials Int 2004:10:549-553 https://doi.org/10.1007/BF03027417
- Weiss EI, Kozak D, Gross MD. Effect of repeated closures on opening torque values in seven abutment-implant systems. J Prosthet Dent 2000:84:194-199 https://doi.org/10.1067/mpr.2000.108069
- Bowden FP, Young L. Influence of interfacial potential on friction and surface damage. Research 1950:3:235-237
- Pihosh Y, Goto M, Kasahara A, Oishi T, Tosa M. Influence of reacting nitrogen gas consistence on the properties of TiN films prepared by rf. magnetron sputtering. Appl Surf Sci 2005:244:244-247 https://doi.org/10.1016/j.apsusc.2004.09.173
- Hagiwara M, Ohashi N. A new tightening technique for threaded fasteners. Mater Eng ASME 1992:371-376