DOI QR코드

DOI QR Code

Seismic performance evaluation of coupled core walls with concrete and steel coupling beams

  • Fortney, Patrick J. (Department of Civil Engineering, Clemson University) ;
  • Shahrooz, Bahram M. (Department of Civil and Environmental Engineering, University of Cincinnati) ;
  • Rassati, Gian A. (Department of Civil and Environmental Engineering, University of Cincinnati)
  • Received : 2007.01.02
  • Accepted : 2007.05.31
  • Published : 2007.08.25

Abstract

When coupling beams are proportioned appropriately in coupled core wall (CCW) systems, the input energy from ground motions is dissipated primarily through inelastic deformations in plastic hinge regions at the ends of the coupling beams. It is desirable that the plastic hinges form at the beam ends while the base wall piers remain elastic. The strength and stiffness of the coupling beams are, therefore, crucial if the desired global behavior of the CCW system is to be achieved. This paper presents the results of nonlinear response history analysis of two 20-story CCW buildings. Both buildings have the same geometric dimensions, and the components of the buildings are designed based on the equivalent lateral force procedure. However, one building is fitted with steel coupling beams while the other is fitted with diagonally reinforced concrete coupling beams. The force-deflection relationships of both beams are based on experimental data, while the moment-curvature and axial load-moment relationships of the wall piers are analytically generated from cross-sectional fiber analyses. Using the aforementioned beam and wall properties, nonlinear response history analyses are performed. Superiority of the steel coupling beams is demonstrated through detailed evaluations of local and global responses computed for a number of recorded and artificially generated ground motions.

Keywords

References

  1. ACI Committee 318, 2005. ACI 318-02/ACI 318R-02 Building Code Requirements for Reinforced Concrete and Commentary, American Concrete Institute. Farmington Hills MI
  2. Canadian Standards Association (CSA) (2004), CSA A23.3-04 Design of Concrete Structures, Rexdale, Canada.
  3. ETABS Nonlinear version 8.4.5, copyright 1984-2004. Computers and Structures, Inc. Computer Program
  4. FEMA-356 (2000),"Prestandard and Commentary for the Seismic Rehabilitation of Buildings", FEMA 356/ November 2000, Building Seismic Safety Council, Washington, D.C.
  5. Fortney, P. J. (2005), Dissertation:"The Next Generation of Coupling Beams", Department of Civil and Environmental Engineering at the University of Cincinnati.
  6. Fortney, P. J., Shahrooz, B. M. and Rassati, G. A. (2006a),"Boundary detailing of coupled core wall system wall piers", ACI Struct. (submitted for review)
  7. Fortney, P. J., Shahrooz, B. M. and Rassati, G. A., (2006b),"Large-scale testing of a replaceable steel coupling beam", J. Struct. Eng. (submitted for review).
  8. Fortney, P. J., Shahrooz, B. M. and Rassati, G. A. (2006c),"Large-scale testing of concrete coupling beams with practical span-to-depth ratios", ACI Struct. J. (submitted for review)
  9. Gong, B., Shahrooz, B. M. (2001a),"Concrete-steel composite coupling beams. I: Component testing", J. Struct. Eng., 625-631.
  10. Gong, B., Shahrooz, B. M. (2001b),"Concrete-steel composite coupling beams. II: Subassembly testing and design verification", J. Struct. Eng., 632-638.
  11. Harries, K. A., Mitchell, D., Cook, W. D. and Redwood, R. G. (1993),"Seismic response of steel beams coupling concrete walls", ASCE, J. Struct. Eng., 119(12), 3611-3629. https://doi.org/10.1061/(ASCE)0733-9445(1993)119:12(3611)
  12. Harries, K. A., Cook, W. D., Mitchell, D. and Redwood, R. G. (1995),"The use of steel beams to couple concrete walls", Proceedings of the Seventh Canadian Conference on Earthquake Engineering, Montreal, Canada, 509-516.
  13. Harries, K. A. and McNiece, D. S. (2005),"Performance-based design of high-rise coupled wall systems", The Structural Design of Tall and Special Structures (in press).
  14. Imbsen Software Systems, 2004. XTRACT - cross sectional X sTRuctural Analysis of ComponenTs v2.6.0. Computer Program.
  15. Paulay, T. and Binney, J. R. (1974),"Diagonally reinforced concrete beams for shear walls", ACI Special Publications SP 42 -Shear in Reinforced Concrete, 579-598.
  16. Paulay, T. (1971),"Coupling beams of reinforced concrete shear walls", ASCE, J. Struct. Div., 97(ST 3), 843-862.
  17. Paulay, T. and Priestley, M. J. N. (1992), Seismic Design of Reinforced Concrete and Masonry Buildings, Wiley Interscience.
  18. Ruaumoko Nonlinear Analysis version 2.6, copyright March 2000. University of Canterbury, Department of Civil Engineering. Computer Program.
  19. Shahrooz, B. M., Remmetter, M. E. and Qin, F. (1992),"Seismic response of composite coupled structural walls", Proceedings of the International Conference on Concrete, 465-481.
  20. Shahrooz, B. M., Remmetter, M. E. and Qin, F. (1993),"Seismic design and performance of composite coupled walls", ASCE, J. Struct. Div., 119(11), 2858-2896.

Cited by

  1. Boundary Detailing of Coupled Core Wall System Wall Piers vol.12, pp.3, 2009, https://doi.org/10.1260/136943309788708383
  2. Performance based evaluation of RC coupled shear wall system with steel coupling beam vol.20, pp.2, 2016, https://doi.org/10.12989/scs.2016.20.2.337
  3. Seismic Design of Hybrid Coupled Wall Systems: State of the Art vol.136, pp.7, 2010, https://doi.org/10.1061/(ASCE)ST.1943-541X.0000186
  4. Steel Coupling Beams with a Replaceable Fuse vol.144, pp.2, 2018, https://doi.org/10.1061/(ASCE)ST.1943-541X.0001939
  5. Seismic Performance of Endplate Connections between Steel Reinforced Concrete Walls and Steel Beams vol.28, pp.2, 2018, https://doi.org/10.1080/10168664.2018.1455490
  6. Cyclic behavior of steel beam-concrete wall connections with embedded steel columns (I): Experimental study vol.23, pp.4, 2007, https://doi.org/10.12989/scs.2017.23.4.399
  7. Cyclic behavior of steel beam-concrete wall connections with embedded steel columns (II): Theoretical study vol.23, pp.4, 2007, https://doi.org/10.12989/scs.2017.23.4.409
  8. Seismic performance of subassemblies with composite wall and replaceable steel coupling beam vol.19, pp.2, 2007, https://doi.org/10.1080/13467581.2020.1718679
  9. Seismic displacements and behaviour factors assessment of an innovative steel and concrete hybrid coupled shear wall system vol.34, pp.None, 2007, https://doi.org/10.1016/j.istruc.2021.07.058