DOI QR코드

DOI QR Code

Stability analysis of semi-rigid composite frames

  • Wang, Jing-Feng (School of Civil Engineering, Tsinghua University) ;
  • Li, Guo-Qiang (School of Civil Engineering, Tongji University, Shanghai, 200092, People's Republic of China State Key Laboratory for Disaster Reduction in Civil Engineering, Tongji University)
  • 투고 : 2006.06.27
  • 심사 : 2007.03.09
  • 발행 : 2007.04.25

초록

Based on stability theory of current rigid steel frames and using the three-column subassemblage model, the governing equations for determining the effective length factor (${\mu}$-factor) of the columns in semirigid composite frames are derived. The effects of the nonlinear moment-rotation characteristics of beam-to-column connections and composite action of slab are considered. Furthermore, using a two-bay three-storey composite frame with semi-rigid connections as an example, the effects of the non-linear moment-rotation characteristics of connections and load value on the ${\mu}$-factor are numerically studied and the ${\mu}$-factors obtained by the proposed method and Baraket-Chen's method are compared with those obtained by the exact finite element method. It was found that the proposed method has good accuracy and can be used in stability analysis of semi-rigid composite frames.

키워드

참고문헌

  1. Kameshki, E. S. and Saka, M. P. (2001),"Optimum design of nonlinear steel frames with semi-rigid connections using a genetic algorithm", Comput. Struct., 79, 1593-1604. https://doi.org/10.1016/S0045-7949(01)00035-9
  2. Liew, J. Y. R. (2002),"Inelastic analysis of steel frames with composite beams", J. Struct. Eng., ASCE, 127(2), 194-202.
  3. Chen, W. F. and Lui, E. M. (1991), Stability Design of Steel Frames, CRC Press, Boca Raton.
  4. Baraket, M. and Chen, W. F. (1990),"Practical analysis of semi-rigid frames", Eng. J., AISC, 27(2), 54-68.
  5. Bjorhovde, R. (1984),"Effect of end restraint on column strength-practical applications", Eng. J., AISC, 212(1), 1-13.
  6. Lui, E. M. (1985),"Effects of connection flexibility and panel zone deformation on the behaviour of plane steel frames", Ph.D thesis, School of Civ. Engrg., Purdue Univ., West Lafayette.
  7. Kishi, N., Chen, W. F. Goto, Y. and Komuro, M. (1998),"Effective length factor of columns in flexibly jointed and braced frames", J. Construct. Steel. Res., 47, 93-118. https://doi.org/10.1016/S0143-974X(98)80104-1
  8. Kishi, N., Chen, W. F. and Goto, Y. (1997),"Effective length factor of columns in semi-rigid and unbraced frames", J. Struct. Eng., ASCE, 123(3), 313-320. https://doi.org/10.1061/(ASCE)0733-9445(1997)123:3(313)
  9. Goto, Y. Lui, E. M. and Chen, W. F. (1993),"Stability behavior of semi-rigid nonsway frames", Eng. Struct., 15(3), 209-219. https://doi.org/10.1016/0141-0296(93)90055-9
  10. Gizejouski, M. A., Papangelis, J. P. and Parameswar, H. C. (1998),"Stability design of semi-continuous steel frame structures", J. Constr. Steel. Res., 46(1-3), 99-101. https://doi.org/10.1016/S0143-974X(98)00009-1
  11. Aristizabal-Ochoa, J. D. (1994),"Stability of columns under uniform axial load with semi-rigid connections", J. Struct. Eng., 120, 3212-3222. https://doi.org/10.1061/(ASCE)0733-9445(1994)120:11(3212)
  12. Bridge, R. Q. and Fraser, D. J. (1987),"Improved G-factor method for evaluating effective lengths of columns", J. Struct. Eng., 113, 1341-1356. https://doi.org/10.1061/(ASCE)0733-9445(1987)113:6(1341)
  13. Cheong-Siat-Moy, F. (1986),"K-factor paradox", J. Struct. Eng., 112, 1747-1760. https://doi.org/10.1061/(ASCE)0733-9445(1986)112:8(1747)
  14. Essa, H.S. (1997),"Stability of columns in unbraced frames", J. Struct. Eng., 123, 952-957. https://doi.org/10.1061/(ASCE)0733-9445(1997)123:7(952)
  15. Hellesland, J. and Bjorhovde, R. (1996),"Improved frame stability analysis with effective lengths", J. Struct. Eng., 122, 1275-1283. https://doi.org/10.1061/(ASCE)0733-9445(1996)122:11(1275)
  16. Ammerman, D. J. and Leon, R. (1990),"Unbranced frames with semirigid composite connections", Eng. J., AISC, 27(1), 1-10.
  17. GB50017 (2003), Code for Design of Steel Structures, Ministry of Construction, China.
  18. AISC (1999), Load and Resistance Factor Design Specification for Structural Steel Building, 3rd. ed. AISC, Chicago, IL, December.
  19. Ahmed, B., Li, T. Q. and Nethercot, D. A. (1997),"Design of composite finplate and angle cleated connections", J. Constr. Steel. Res., 41(1), 1-29. https://doi.org/10.1016/S0143-974X(96)00052-1
  20. Xiao, Y., Choo, B. S. and Nethercot, D. A. (1996),"Composite connections in steel and concrete. Part 2 ? Moment capacity of end plate beam to column connections", J. Constr. Steel. Res., 37(1), 63-90. https://doi.org/10.1016/0143-974X(95)00015-N
  21. Ahmed, B. and Nethercot, D. A. (1997),"Prediction of initial stiffness and available rotation capacity of majoraxis flush end-plate connections", J. Constr. Steel. Res., 41(1), 31-60. https://doi.org/10.1016/S0143-974X(96)00053-3
  22. Eurocode 3. (2004), Design of steel structures Part 1.1: General rules and rules for buildings", CEN Brussels 2004, CEN Document EN 1993-1-1.
  23. Xu, L. (2002),"The bucking loads of unbraced PR frames under no-proportional loading", J. Constr. Steel. Res., 58, 443-465. https://doi.org/10.1016/S0143-974X(01)00065-7
  24. Xu, L. and Liu, Y. (2000),"Storey stability of semi-braced steel frames", J. Constr. Steel. Res., 58, 467-491.

피인용 문헌

  1. Axial load effects on flush end-plate moment connections vol.170, pp.3, 2017, https://doi.org/10.1680/jstbu.15.00042
  2. Buckling analysis of semi-rigid gabled frames vol.55, pp.3, 2015, https://doi.org/10.12989/sem.2015.55.3.605
  3. Standardization of composite connections for trapezoid web profiled steel sections vol.55, pp.4, 2015, https://doi.org/10.12989/sem.2015.55.4.765
  4. Optimum design of steel frames with semi-rigid connections and composite beams vol.55, pp.2, 2015, https://doi.org/10.12989/sem.2015.55.2.299
  5. Behavior of Composite Beam-Column Joints in a Middle-Column-Removal Scenario: Experimental Tests vol.140, pp.2, 2014, https://doi.org/10.1061/(ASCE)ST.1943-541X.0000805
  6. Comparison of component method with experimental tests for flush end-plate connections using hot-rolled perwaja steel sections vol.9, pp.2, 2009, https://doi.org/10.1007/BF03249491
  7. Behaviour of steel cap plate connections: Experimental tests vol.14, pp.3, 2014, https://doi.org/10.1007/s13296-014-3022-9
  8. Optimum design of composite steel frames with semi-rigid connections and column bases via genetic algorithm vol.19, pp.4, 2015, https://doi.org/10.12989/scs.2015.19.4.1035
  9. Lifetime seismic performance assessment of high-rise steel-concrete composite frame with buckling-restrained braces under wind-induced fatigue vol.77, pp.2, 2007, https://doi.org/10.12989/sem.2021.77.2.197
  10. Experimental Database for Steel Flush End-Plate Connections vol.147, pp.7, 2007, https://doi.org/10.1061/(asce)st.1943-541x.0003064