DOI QR코드

DOI QR Code

Experimental investigation of force-distribution in high-strength bolts in extended end-plate connections

  • Abdalla, K.M. (Civil Engineering Department, Jordan University of Science and Technology) ;
  • Abu-Farsakh, G.A.R. (Civil Engineering Department, Jordan University of Science and Technology) ;
  • Barakat, S.A. (Civil Engineering Department, Jordan University of Science and Technology)
  • 투고 : 2006.03.24
  • 심사 : 2006.11.20
  • 발행 : 2007.04.25

초록

This paper presents some of the results from an experimental research project on the behavior of extended end-plate connections subjected to moment conducted at the Structural Laboratory of Jordan University of Science and Technology. Since the connection behavior affects the structural frame response, it must be included in the global analysis and design. In this study, the behavior of six full-scale stiffened and unstiffened cantilever connections of HEA- and IPE-sections has been investigated. Eight high strength bolts were used to connect the extended end-plate to the column flange in each case. Strain gauges were installed inside each of the top six bolts in order to obtain experimentally the actual tension force induced within each bolt. Then the connection behavior is characterized by the tension force in the bolt, extended end-plate behavior, moment-rotation relation, and beam and column strains. Some or all of these characteristics are used by many Standards; therefore, it is essential to predict the global behavior of column-beam connections by their geometrical and mechanical properties. The experimental test results are compared with two theoretical (equal distribution and linear distribution) approaches in order to assess the capabilities and accuracy of the theoretical models. A simple model of the joint is established and the essential parameters to predict its strength and deformational behavior are determined. The equal distribution method reasonably determined the tension forces in the upper two bolts while the linear distribution method underestimated them. The deformation behavior of the tested connections was characterized by separation of the column-flange from the extended end-plate almost down to the level of the upper two bolts of the lower group and below this level the two parts remained in full contact. The neutral axis of the deformed joint is reasonably assumed to pass very close to the line joining the upper two bolts of the lower group. Smooth monotonic moment-rotation relations for the all tested frames were observed.

키워드

참고문헌

  1. Abel, M. and Murray, T. M. (1994),"Analytical and experimental investigation of the extended unstiffened moment end-plate connections with four at beam flange", Report No. CE/VPI-ST 93/8. Virginia Polytechnic Institute and State University, Blacksburg, Virginia.
  2. American Institute of Steel Construction. (2005), AISC/LRFD Steel Construction Manual, 13 Edition.
  3. Baniotopoulos C. C. (1995),"On the separation problem in bolted steel splice plates", J. Constr. Steel Res., 32, 15-33. https://doi.org/10.1016/0143-974X(94)00008-6
  4. Baniotopoulos, C. C., Mistakidis, E. S., Bisbos, C. D. and Panagiotopoulos, P. D. (1996),"A 2D numerical model for the analysis T-stub connections", C1/WG6/1996-09. Meeting No 6, Clermont-Ferrand.
  5. British Standards Institution. (2001), BS 5950: Part 1: Structural use of steelwork in building. London, BSI.
  6. Bursi, O. S. and Jaspart, J. P. (1997),"Benchmark for finite element modeling of bolted steel connections", J. Constr. Steel Res., Elsevier, 43(1-3), 17-42. https://doi.org/10.1016/S0143-974X(97)00031-X
  7. Chen, W. F. and Kishi, N. (1989),"Semi rigid steel beam-to-column connections: Data base and modeling", J. Struct. Eng., ASCE, 115(1), 105-119. https://doi.org/10.1061/(ASCE)0733-9445(1989)115:1(105)
  8. Coelho, Ana M. Girao, Bijlaard, Frans S. K. and Simoes da Silva, Luis (2004),"Experimental assessment of the ductility of extended end-plate connections", J. Eng. Struct., 26, 1185-1206. https://doi.org/10.1016/j.engstruct.2000.09.001
  9. Coelho, Ana M. Girao, Bijlaard, Frans S. K., Gresnigt, Nol and Simoes da Silva, Luis (2004),"Experimental assessment of the behavior of bolted T-stub connections made up of welded plates", J. Constr. Steel Res., 60, 269-311. https://doi.org/10.1016/j.jcsr.2003.08.008
  10. European Committee for Standardization (CEN). PrEN 1993; (1-8): 2003, Eurocode 3: Design of steel structures. Part 1.8: Design of joints. Stage 49 draft, Brussels; 2003.
  11. Gebbeken, N., Rothert, H. and Binder, B. (1994),"On the numerical analysis of end-plate connections", J. Constr. Steel Res., Elsevier, 30, 177-196. https://doi.org/10.1016/0143-974X(94)90049-3
  12. Gomes, F. C., Neves, L. F., Sliva, L. and Simoes, R. (1995),"Numerical simulation of a T-stub", Document C1/ WG6/1995-21. Meeting No 5, Graz.
  13. Jaspart, J. P. (1994),"Numerical simulation of T-stub ? Experimental data", Document C1/WG6/1994-09. Meeting No 2, London.
  14. Jaspart, J. P. (1997),"Contributions to recent advance in the field of steel joints, column base and further configurations for beam-to-column joints and beam splices", Aggregation Thesis. University of Liege, Liege.
  15. Jaspart, J. P., Mac, B. and Cerfontaine, F. (1999),"Strength of joints subject to combined action of bending moments and axial forces", Eurosteel 1999- Second European Conference on Steel Structures, Prague, Cezeh Republic.
  16. Jolly, C. K. (1995),"Numerical simulation of a T-stub connection ? Implications for more general simulations", Document C1/WG6/1995-13. Meeting No 5, Graz.
  17. Meng, R. (1996),"Design of moment end-plate connections for seismic loading", Doctoral Dissertation, Virginia Polytechnic Institute and State University, Blacksburg, Virginia.
  18. Mistakidis, E. S., Baniotopoulos, C. C., Bisbos, C. D. and Panagiotopoulos, P. C. (1996),"Steel T-stub connection under static loading: an effective 2-D numerical model", J. Constr. Steel Res., 44(1-2), 51-67.
  19. Ragupathy, P. and Virdi, K. S. (1995),"Numerical simulation of a T-stub connection using ANSYS", Document C1/WG6/1995-16. Meeting No 4, Trento.
  20. Troup, S., Xiao, R. Y. and Moy, S. S. J. (1998),"Numerical modeling of bolted steel connections", J. Constr. Steel Res., 46(1-3): Paper No. 362.
  21. Wald, F. and Baniotopoulos, C. H. (1998),"Numerical modeling of column base connection. COST C1, control of the semi-rigid behavior of civil engineering structural connections", Proceeding of the International Conference Liege, 17-19 Septemper pp 497-506.
  22. Wald, F., Villanova, F. and Zuhilke, A. (1997),"2D and 3D modelling of a T-stub, the COST C1 example", Document C1/WG6/1997-3 No 7, Munchen.
  23. Zoetemeijer, P. (1990),"Summery of the research on bolted beam-to-column connections", Report 26-6-90-2. Delft University of Technology. Faculty of Civil Engineering, Stevin Laboratory ? Steel Structures.

피인용 문헌

  1. Improving seismic performance of framed structures with steel curved dampers vol.130, 2017, https://doi.org/10.1016/j.engstruct.2016.09.063
  2. Finite element analysis of flush end-plate connections connected to column web vol.11, pp.3, 2011, https://doi.org/10.1007/s13296-011-3001-3
  3. Comparison of component method with experimental tests for flush end-plate connections using hot-rolled perwaja steel sections vol.9, pp.2, 2009, https://doi.org/10.1007/BF03249491
  4. Experimental and analytical investigations on seismic behavior of ductile steel knee braced frames vol.16, pp.1, 2014, https://doi.org/10.12989/scs.2014.16.1.001
  5. Numerical and experimental investigation of the behavior of extended end-plate connections in steel structures vol.6, pp.3, 2011, https://doi.org/10.1556/Pollack.6.2011.3.2
  6. Experimental evaluation on the seismic performance of steel knee braced frame structures with energy dissipation mechanism vol.11, pp.1, 2011, https://doi.org/10.12989/scs.2011.11.1.077
  7. Experimental Investigation of Retrofitted Extended End-Plate Connections vol.284-287, pp.1662-7482, 2013, https://doi.org/10.4028/www.scientific.net/AMM.284-287.1330
  8. Behavior of Extended End-Plate Steel Beam to Column Connections vol.12, pp.None, 2007, https://doi.org/10.2174/1874149501812010250
  9. Numerical Evaluation of Prequalified End-Plate Connections Used in a Framed Steel Industrial Structure vol.11, pp.2, 2021, https://doi.org/10.3390/met11020243