DOI QR코드

DOI QR Code

Nonlinear finite element analysis of four-pile caps supporting columns subjected to generic loading

  • de Souza, Rafael Alves (Departamento de Engenharia Civil, Universidade Estadual de Maringa) ;
  • Kuchma, Daniel Alexander (Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign) ;
  • Park, Jung-Woong (Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign) ;
  • Bittencourt, Tulio Nogueira (Departamento de Engenharia de Estruturas e Fundacoes, Escola Politecnica da Universidade de Sao Paulo)
  • Received : 2006.12.03
  • Accepted : 2007.09.01
  • Published : 2007.10.25

Abstract

The paper presents the development of an adaptable strut-and-tie model that can be applied to the design or analysis of four-pile caps that support axial compression and biaxial flexure from a supported rectangular column. Due to an absence of relevant test data, the model is validated using nonlinear finite element analyses (NLFEA). The results indicate that the use of the proposed model would lead to safe and economical designs. The proposed model can be easily extended to any number of piles, providing a rational procedure for the design of wide range of pile caps.

Keywords

References

  1. ACI Committee 318 (2002), "Building code requirements for reinforced concrete (ACI 318-02) and commentary (ACI 318R-05)". American Concrete Institute, Farmington Hills, MI.
  2. Adebar, P., Kuchma, D. and Collins, M. P. (1990), "Strut-and-tie models for the design of pile caps: an experimental study", ACI Struct. J., 87(1), pp. 81-92.
  3. Adebar, P. and Zhou, Z. (1996), "Design of deep pile caps by strut-and-tie models", In: ACI Structural Journal, 93(4), July-August, 1-12.
  4. American Association of State Highway and Transportation Officials (AASHTO), "AASHTO LRFD Bridge design specifications", 1st ed. Washington, D.C. 1994.
  5. Blevot, J. L. and Fremy, R. (1967), "Semelles sur pieux", Institute Technique du Batiment et des Travaux Publics, 20(230), 223-295, Paris.
  6. Bloodworth, A. G., Jackson, P. A., Lee, M. M. K. (2003), "Strength of reinforced concrete pile caps". Proceedings of the Institution of Civil Engineers, Structures & Buildings 156, November, Issue SB4, 347-358.
  7. Canadian Standards Association (CSA). "CSA A23.3-M84. Code for the design of concrete structures for buildings". RexdaIe, Ont., 281, pp, 1984.
  8. Cavers, W. and Fenton, G. A. (2004), "An Evaluation of pile cap design methods in accordance with the canadian design standard", Canadian J. Civ. Eng., 31(1), February, 109-119. https://doi.org/10.1139/l03-075
  9. Cervenka, V., Jendele, L. and Cervenka, J. (2005), "Atena program documentation -Part 1: theory", Praha, Czech Republic.
  10. Comision Permanente Del Hormigon (1999), "EHE - Instruccion de hormigon structural". Madrid, Spain, 1999. (In Spanish)
  11. Clarke, J. L. (1973), "Behavior and design of pile caps with four piles", Technical Report, 42.489, Cement and Concrete Association, Wexham Springs.
  12. Reineck, K., H, ed. (2002) "Examples for the design of structural concrete with strut and tie models", Chapter 9, pp. 213-224. ACI SP-208. Farmington Hills, MI: ACI International.
  13. Iyer. P, K. and Sam, C. (1992), "Three-dimensional analysis of pile caps", Comput. & Struct., 42(3), pp. 395-411. https://doi.org/10.1016/0045-7949(92)90036-Y
  14. Schlaich, J., Schafer, K. and Jennewein, M. (1987), "Toward a consistent design of reinforced concrete structures", J. Prestressed Concrete Struct., 32(3), pp.74-150.
  15. SuzukI, K. and Otsuki, K. (2002), "Experimental study on corner shear failure of pile caps", Transactions of the Japan Concrete Institute, 23.
  16. Suzuki, K., Otsuki, K. and Tsubata, T. (1999), "Experimental study on four-pile caps with taper", Transactions of the Japan Concrete Institute, 21, 327-334.
  17. Suzuki, K., Otsuki, K. and Tsubata, T. (1998), "Influence of bar arrangement on ultimate strength of four-pile caps", Transactions of the Japan Concrete Institute, 20, 195-202.
  18. Suzuki, K., Otsuki, K. and Tsuchiya, T. (2000), "Influence of edge distance on failure mechanism of pile caps". Transactions of the Japan Concrete Institute, 22, 361-367.

Cited by

  1. Collapse mechanisms and strength prediction of reinforced concrete pile caps vol.35, 2012, https://doi.org/10.1016/j.engstruct.2011.11.006
  2. A 3D finite element model for reinforced concrete structures analysis vol.4, pp.4, 2011, https://doi.org/10.1590/S1983-41952011000400002
  3. Design-Oriented Testing and Modeling of Reinforced Concrete Pile Caps vol.23, pp.8, 2007, https://doi.org/10.1007/s12205-019-1650-5
  4. Settlement analysis of pile cap with normal and under-reamed piles vol.25, pp.6, 2007, https://doi.org/10.12989/cac.2020.25.6.525
  5. Finite Element Analysis of Reinforced Concrete Pile Cap using ATENA vol.18, pp.2, 2007, https://doi.org/10.1590/1679-78256290