DOI QR코드

DOI QR Code

Consistent thermal analysis procedure of LNG storage tank

  • Jeon, Se-Jin (DAEWOO E&C, Institute of Construction Technology) ;
  • Jin, Byeong-Moo (DAEWOO E&C, Institute of Construction Technology) ;
  • Kim, Young-Jin (DAEWOO E&C, Institute of Construction Technology) ;
  • Chung, Chul-Hun (Department of Civil and Environmental Engineering, Dankook University)
  • 투고 : 2005.08.22
  • 심사 : 2006.09.19
  • 발행 : 2007.03.10

초록

As the LNG (Liquefied Natural Gas) tank contains cryogenic liquid, realistic thermal analyses are of a primary importance for a successful design. The structural details of the LNG tank are so complicated that some strategies are necessary to reasonably predict its temperature distribution. The proposed heat transfer model can consider the beneficial effects of insulation layers and a suspended deck on temperature distribution of the outer concrete tank against cryogenic conditions simply by the boundary conditions of the outer tank model. To this aim, the equilibrium condition or heat balance in a steady state is utilized in a various way, and some aspects of heat transfer via conduction, convection and radiation are implemented as necessary. Overall thermal analysis procedures for the LNG tank are revisited to examine some unjustifiable assumptions of conventional analyses. Concrete and insulation properties under cryogenic condition and a reasonable conversion procedure of the temperature-induced nonlinear stress into the section forces are discussed. Numerical examples are presented to verify the proposed schemes in predicting the actual temperature and stress distributions of the tank as affected by the cryogenic LNG for the cases of normal operation and leakage from the inner steel tank. It is expected that the proposed schemes enable a designer to readily detect the effects of insulation layers and a suspended deck and, therefore, can be employed as a useful and consistent tool to evaluate the thermal effect in a design stage of an LNG tank as well as in a detailed analysis.

키워드

참고문헌

  1. ACI Committee 349 (2001), Commentary on Code Requirements for Nuclear Safety Related Concrete Structures (ACI 349R-01), American Concrete Institute, Mich
  2. ANSYS - User's Manual. Ver. 8.0 (2004), ANSYS, Inc
  3. Association of German Engineers (VDI) and VDI Society for Chemical and Process Engineering (1993), VDI Heat Atlas, VDI- Verlag GmbH, Dusseldorf, Germany
  4. Bangash, M.Y.H. (1989), Concrete and Concrete Structures: Numerical Modelling and Application, Elsevier Applied Science, NY
  5. Chen, Q.S., Wegrzyn, J. and Prasad, V (2004), 'Analysis of temperature and pressure changes in liquefied natural gas (LNG) cryogenic tanks', Cryogenics, 44(10), 701-709 https://doi.org/10.1016/j.cryogenics.2004.03.020
  6. Choi, C.K., Lee, T.Y. and Lee, E.J. (2002), 'Improved finite element models for the in-ground LNG storage tank', J. the Korean Society of Civil Engineers, 22(5-A), 1175-1182
  7. DAELIM Industrial Co., Ltd. and DYWIDAG (1995), Inchon LNG-receiving Terminal (lst Extension)
  8. DAEWOO Corp., DAELIM Industrial Co., Ltd. and OBAYASHI Corp. (1999), Tongyoung LNG Terminal Project
  9. Ghali, A. and Elliott, E. (1992), 'Serviceability of circular prestressed concrete tanks', ACI Struct. J., 89(3), 345-355
  10. Ghali, A. and Favre, R. (1994), Concrete Structures: Stresses and Deformations, 2nd ed., E & FN Spon, London
  11. Goto, Y. and Miura, T. (1979), 'Experimental studies on properties of concrete cooled to about minus 160°C', Technology Reports (Tohoku Univ.), 44(2), 357-385
  12. Ivanyi, G. (1987), 'Local and global cryogenic attacks', Proc. of the 1st Int. Corf. on Concrete for Hazard Protection
  13. Japan Gas Association (1979), Recommended Practice for LNG Inground Storage (RPIS)
  14. Jeon, S.J. (2004), 'Consistent assessment for liquid tightness of LNG storage tank subjected to cryogenic temperature-induced forces', J. the Korean Society of Civil Engineers, 24( I-A), 203-210
  15. Jeon, S.J., Chung, C.H., Jin, B.M. and Kim, Y.J. (2004), 'Liquid tightness design of LNG storage tank incorporating cryogenic temperature-induced stresses', Proc. of CONSEC'04, Korea
  16. Miura, T. (1989), 'The properties of concrete at very low temperatures', Materials and Structures, 22(130), 243-254 https://doi.org/10.1007/BF02472556
  17. Nakano, M. (2001), 'Technological trend and latest technological development of LNG inground storage tanks', J. Construction Management and Engineering (Japan Society of Civil Engineers), 51(679), 1-20
  18. Nawy, E.G. (1985), 'Flexural cracking behavior of pretensioned and post-tensioned beams: The state of the art', ACI J., 82(6), 890-900
  19. Rashed, A., Elwi, A.E. and Rogowsky, D.M. (2002), 'Reinforced, partially prestressed concrete water tank walls', ACI Struct. J., 99(3), 288-298
  20. Shekarchi, M., Debicki, G, Granger, L. and Billard, Y. (2002), 'Study of leaktightness integrity of containment wall without liner in high performance concrete under accidental conditions - I. Experimentation', Nucl. Eng. Des., 213(1), 1-9 https://doi.org/10.1016/S0029-5493(01)00521-0
  21. Suri, K.M. and Dilger, W.H. (1986), 'Crack width of partially prestressed concrete members', ACI J., 83(5), 784-797
  22. Watanabe, N., Endo, H., Xuehui, A., Nakano, M. and Aoki, H. (2003), 'Application of non-linear analysis to structural design of a LNG inground tank', J. Construction Management and Engineering (Japan Society of Civil Engineers), 60(742), 87-100
  23. Wermann, T. (1998), 'Cryogenic cube tests - Leakage, temperature, deformation', http://www.concrete.ct.tudelft. nl

피인용 문헌

  1. Thermal stress analysis of concrete wall of LNG tank during construction period vol.49, pp.6, 2016, https://doi.org/10.1617/s11527-015-0656-9
  2. Estimation of the energy efficiency of cryogenic filled tank use in different systems and devices vol.101, 2016, https://doi.org/10.1016/j.applthermaleng.2015.09.052
  3. Assessment of the fire resistance of a nuclear power plant subjected to a large commercial aircraft crash vol.247, 2012, https://doi.org/10.1016/j.nucengdes.2012.02.003
  4. Probabilistic analysis of a liquefied natural gas storage tank vol.30, pp.17-18, 2010, https://doi.org/10.1016/j.applthermaleng.2010.07.033
  5. Numerical analysis for behavior of outer concrete tank in emergency LNG spillage vol.14, pp.4, 2014, https://doi.org/10.12989/cac.2014.14.4.369
  6. Finite Element Modeling of Shop Built Spherical Pressure Vessels vol.05, pp.06, 2013, https://doi.org/10.4236/eng.2013.56064
  7. Analysis of two main LNG CCS (cargo containment system) insulation boxes for leakage safety using experimentally defined thermal properties vol.37, 2012, https://doi.org/10.1016/j.apor.2012.04.002
  8. Application of Hermitian wavelet finite element method on temperature field analysis of LNG tank under ultra-low temperature vol.121, pp.2, 2015, https://doi.org/10.1007/s10973-015-4627-8
  9. Prestressing Effect of LNG Storage Tank with 2,400 MPa High-Strength Strands vol.36, pp.6, 2016, https://doi.org/10.12652/Ksce.2016.36.6.0999
  10. Rapid calculation procedure to determine the pressurizing period for stored cryogenic fluids vol.30, pp.14-15, 2010, https://doi.org/10.1016/j.applthermaleng.2010.05.002
  11. Temperature Field Analysis of LNG Tank under Ultra-Low Temperature Based on Finite Element Method vol.733, pp.1662-7482, 2015, https://doi.org/10.4028/www.scientific.net/AMM.733.566
  12. Thermal Cycling Toughness and Strength Estimation of Cryogenic Filled Tank vol.179, pp.2261-236X, 2018, https://doi.org/10.1051/matecconf/201817901014
  13. Early-age thermal analysis and strain monitoring of massive concrete structures vol.21, pp.3, 2018, https://doi.org/10.12989/cac.2018.21.3.279
  14. Automatic air-cooling system for early-age crack control in concrete vol.172, pp.5, 2007, https://doi.org/10.1680/jcien.18.00036
  15. Optimum Arrangement Design of Mastic Ropes for Membrane-Type LNG Tanks Considering the Flatness of Thermal Insulation Panel and Production Cost vol.8, pp.5, 2020, https://doi.org/10.3390/jmse8050353
  16. Energy Saving through Efficient BOG Prediction and Impact of Static Boil-off-Rate in Full Containment-Type LNG Storage Tank vol.13, pp.21, 2007, https://doi.org/10.3390/en13215578