References
- ACI (1968), 'Manual of concrete practice', Part 2, Committee 318-1R-68, American Concrete Institute, Detroit
- ACI (2002), 'Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures', Committee 440 Report 440.2R-02, American Concrete Institute, Detroit
- CSA (1994), 'Design of concrete structures', Standard A23.3, Canadian Standards Association, Rexdale, Ontario
- FEMA 273/274 (1997), 'NEHRP guidelines for the seismic rehabilitation for buildings', Federal Emergency Management Agency, Washington D.C
- FIB (2001), 'Externally bonded FRP reinforcement for RC structures', Technical Report Bulletin No. 14, Federation Internationale du Beton, France
- Galal, K., Arafa, A. and Ghobarah, A. (2005), 'Retrofit of RC square short columns', J. Eng. Struct., 27(5),801-813 https://doi.org/10.1016/j.engstruct.2005.01.003
- Galal, K. and Ghobarah, A. (2003), 'Flexural and shear hysteretic behaviour of reinforced concrete columns with variable axial load', J. Eng. Struct., 25(11), 1353-1367 https://doi.org/10.1016/S0141-0296(03)00111-1
- Ghobarah, A. and Galal, K. (2004), 'Seismic rehabilitation of short rectangular RC columns', J. Earthq. Eng., 8(1), 45-68 https://doi.org/10.1142/S1363246904001316
- Haroun, M.A., Mosallam, A.S., Feng, M.Q. and Elsanadedy, H.M. (2002), 'Composite jackets for the seismic retrofit and repair of bridge columns', 7th U.S. Nat. Conf. Earthquake Eng., Oakland, California
- ISIS Canada (2001), 'Strengthening reinforced concrete structures with externally-bonded fibre reinforced polymers (FRPs)', Design Manual, University of Manitoba
- Kowalsky, M.J., Priestley, M.J.N. and Seible, F. (1999), 'Shear and flexural behavior of lightweight concrete bridge columns in seismic regions', ACI Struct. J., 96(1), 136-148
- Mander J.B., Priestley, M.J.N. and Park, R. (1988), 'Theoretical stress-strain model for confined concrete', J. Struct. Eng., ASCE, 114(8), 1804-1826 https://doi.org/10.1061/(ASCE)0733-9445(1988)114:8(1804)
- NISEE (2006), http://nisee.berkeley.edu/elibrary, Images, Shear Column, Retrieved Jan. 2006
- Priestley, M.J.N., Verma, R. and Xiao, Y. (1994), 'Seismic shear strength of reinforced concrete columns', J. Struct. Eng., ASCE, 120(8), 2310-2329 https://doi.org/10.1061/(ASCE)0733-9445(1994)120:8(2310)
- Seible, F., Priestley, M.J.N., Hegemier, G.A. and Innamorato, D. (1997), 'Seismic retrofit of RC columns with continuous carbon fibre jackets', J. Compos. Constr, ASCE, 1(2), 52-62 https://doi.org/10.1061/(ASCE)1090-0268(1997)1:2(52)
- Vision 2000 committee (1995), 'Performance based seismic engineering of buildings', Str. Eng. Assoc. of California (SEAOC), Sacramento, California
- Ye, L., Yue, Q., Zhao, S. and Li, Q. (2002), 'Shear strength of reinforced concrete columns strengthened with carbon-fiber-reinforced plastic sheet', J. Struct. Eng., 128(12), 1527-1534 https://doi.org/10.1061/(ASCE)0733-9445(2002)128:12(1527)
- Yoshimura, K., Kikuchi, K., Kuroki, M., Ozawa, K. and Masuda, Y. (2000), 'Experimental study on seismic behavior of R/C short columns strengthened by carbon fiber sheets', Composite and Hybrid Structures: Proc. of the 6th ASCCS Int. Conf. on Steel-Concrete Composite Structures, Los Angeles, California, 927-934
Cited by
- Analytical Evaluation of Seismic Performance of RC Frames Rehabilitated Using FRP for Increased Ductility of Members vol.22, pp.5, 2008, https://doi.org/10.1061/(ASCE)0887-3828(2008)22:5(276)
- Influence of concurrent horizontal and vertical ground excitations on the collapse margins of non-ductile RC frame buildings vol.59, pp.4, 2016, https://doi.org/10.12989/sem.2016.59.4.653
- Seismic strengthening of rectangular reinforced concrete columns using fiber reinforced polymers vol.32, pp.4, 2010, https://doi.org/10.1016/j.engstruct.2009.12.021
- Analytical investigation of the seismic performance of RC frames rehabilitated using different rehabilitation techniques vol.31, pp.9, 2009, https://doi.org/10.1016/j.engstruct.2009.02.048
- Strengthening and Retrofitting of the Industries Building After Fires vol.671-674, pp.1662-8985, 2013, https://doi.org/10.4028/www.scientific.net/AMR.671-674.778
- Maximum axial load level and minimum confinement for limited ductility design of high-strength concrete columns vol.6, pp.5, 2007, https://doi.org/10.12989/cac.2009.6.5.357
- Concurrent flexural strength and deformability design of high-performance concrete beams vol.40, pp.4, 2007, https://doi.org/10.12989/sem.2011.40.4.541
- Numerical simulation of bridge piers with spread footings under earthquake excitation vol.16, pp.6, 2019, https://doi.org/10.12989/eas.2019.16.6.691