The Journal of Korean Society for Radiation Therapy (대한방사선치료학회지)
- Volume 19 Issue 2
- /
- Pages.107-112
- /
- 2007
- /
- 1598-8449(pISSN)
The Investigation Regarding the Dose Change due to the Heterogeneity of Prostate Cancer Treatment with IMRT
전립선암의 세기조절 방사선치료 시 불균질부에 의한 선량변화에 관한 고찰
- Yoon, Il-Kyu (Department of Radiation Oncology, Seoul National University Hospital) ;
- Park, Jang-Pil (Department of Radiation Oncology, Seoul National University Hospital) ;
- Lee, Jae-Hee (Department of Radiation Oncology, Seoul National University Hospital) ;
- Park, Heung-Deuk (Department of Radiation Oncology, Seoul National University Hospital)
- Published : 2007.09.30
Abstract
Purpose: The pelvic phantom was fabricated in the following purposes: (1) Dose verification of IMRT plan using Eclipse planning computer, (2) to study the interface effect at the interface between rectal wall and air. The TLD can be inserted in the pelvic phantom to confirm the dose distribution as well as uncertainty at the interface. Materials and Methods: A pelvic phantom with the dimension of 30 cm diameter, 20 cm height and 20 cm thickness was fabricated to investigate the dose at the rectal wall. The phantom was filled with water and has many features like bladder, rectum, and prostate and seminal vesicle (SV). The rectum is made of 3 cm-dimater plastic pipe, and it cab be blocked by using a plug, and film can be inserted around the rectal wall. The phantom was scanned with Philips Brillance scanner and various organs such as prostate, SV, and rectal wall, and bladder wall were delineated. The treatment parameters used in this study are the same as those used in the protocols in the SNUH. TLD chips are inserted to the phantom to evaluate the dose distribution to the rectal wall (to simulate high dose gradient region), bladder wall and SV (to simulate the high dose region) and 2 spots in anterior surface (to simulate the low dose region). The TLD readings are compared with those of the planning computer (ECLIPSE, Varian, USA). Results: The target TLD doses represented as the prostate and SV show excellent agreements with the doses from the RTP within +/-3%. The rectal wall doses measured at the rectal wall are different from the those of the RTP by -11%. This is in literatures called as an interface effect. The underdosages at the rectal wall is independent of 3 heterogeneity correction algorithm in the Eclipse RTP. Also the low dose regions s represented as surface in this study were within +/-1%. Conclusion: The RTP estimate the dosage very accurately withihn +/-3% in the high dose (SV, or prostate) and low dose region (surface). However, the dosage at the rectal wall differed by as much as 11% (In literatures, the underdosage of 9
목 적: 본원에서 시행하고 있는 전립선암의 세기조절 방사선치료시 직장 내에 존재하는 불균질부에 의한 선량변화를 전산화 치료계획 선량과 자체 제작한 전립선암 환자형 골반 팬톰을 이용하여 측정한 선량을 비교하고자 한다. 대상 및 방법: 전립선암 환자형 골반 팬톰(타원형의 물 팬톰: