References
- R. D. Schmid and F. Scheller, 'Biosensors Applications in Medicine, Environmental Protection and Process Control', Vol. 13, p. 4. Weinheim Germany, 1989
- R. P. Buck, W. E. Hatfield, M. Umana, and E. F. Bowden, 'Biosensor Technology', p. 3, Marcel Dekker, Inc. U.S.A. 1990
- A. N. Reshetilov, M. V. Donova, D. V. Dovbnya and A. M. Boronin, 'FET-microbial Sensor for Xylose detection based on Gluconobacter oxydans Cells', Biosensors & Bioelectronics, 11, 401 (1996) https://doi.org/10.1016/0956-5663(96)82735-7
- V. C. Sanz, M. L. Mena, A. G. Cortes, P. Yanez-Sedeno and J. M. Pingarron, 'Development of a Tyrosinase biosensor based on Gold nanoparticlesmodified Glassy carbon electrodes Application to the Measurement of a Bioelectrochemical polyphenols Index in Wines', Anal. Chim. Acta, 528, 1 (2005) https://doi.org/10.1016/j.aca.2004.10.007
- P. Mailley, E. A. Cummings, S. Mailley, S. Cosnier, B. R. Eggins and E. McAdams, 'Amperometric detection of Phenolic compounds by Polypyrrole-based composite Carbon paste Electrodes', Biochemistry, 63, 291 (2004)
- I. Vostiar, J. Tkac, E. Sturdik and P. Gemeiner, 'Amperometric urea biosensor based on Urea and Electropolimerized Toludine blue dye as a pH-sensitive Redox probe', Biochemistry, 56, 113 (2002)
- E. Crouch, D. C. Cowell, S. Hoskins, R. W. Pittson and J. P. Hart, 'Amperometric, Screen-printed, Glucose biosensor for Analysis of human plasma samples using a Biocomposite water-based Carbon ink incorporating Glucose oxidase', Anal. Biochem. 347, 17 (2005) https://doi.org/10.1016/j.ab.2005.08.011
- K. J. Yoon, K. J. Kim, and H. S. Kwon, 'Electrochemical Properties of the Chicken Small Intestinal Tissue based Enzyme Electrode for the Determination of Hydrogen Peroxide', J. Kor. Chem. Soc. 43(3), 271 (1999)
- K. J. Yoon, H. S. Kwon, and B. G. Lee, 'Electrochemical Determination of pH-Stability Curve of Enzyme', J. Kor. Chem. Soc. 49(3), 325 (2005) https://doi.org/10.5012/jkcs.2005.49.3.325
- H. S. Kwon, E. H. Jin, K. J. Yoon and Y. N. Pak, 'Mushroom-juice based Gold Electrode for the Determination of Phenols', J. Kor. Chem. Soc. 49(2), 224 (2005) https://doi.org/10.5012/jkcs.2005.49.2.224
- K. J. Yoon, 'Optimum pH of the Reduction of Hydrogen peroxide at a Tobacco plant Tissue based Amperometric Biosensor', J. Kor. Chem. Soc. 48(6), 654 (2004) https://doi.org/10.5012/jkcs.2004.48.6.654
- K. J. Yoon, 'A New Strategy for Determining Optimum pH of Isozymes', Bull. Kor. Chem. Soc. 25(7), 997 (2004) https://doi.org/10.5012/bkcs.2004.25.7.997
- K. J. Yoon, 'Electrochemical Determination of the Optimum pH of HRP', Anal. Sci. Tech. 16(6), 504 (2003)
- J. A. Brydson, 'Rubbery Materials and Their Compounds', p. 147, Elsevier Applied Science, London and New York, 1988
- J. Wang, N. Naser, H. S. Kwon, and M. Y. Cho, 'Tissue bioelectrode for Organic-phase Enzymatic Assays', Anal. Chim. Acta, 264, 7 (1992) https://doi.org/10.1016/0003-2670(92)85290-M
- B. Wang and S. Dong, 'Sol-gel-derived Amperometric Biosensor for Hydrogen peroxide based on Methylene green Incorporated in Nafion film', J. Electroanal. Chem. 487, 45 (2000) https://doi.org/10.1016/S0022-0728(00)00152-2
- A. N. Diaz, M. C. R. Peinado and M. C. T. Minguez, 'Sol-gel Horseradish Peroxidase Biosensor for Hydrogen peroxide Detection by Chemiluminescence', Anal. Chim. Acta, 363, 221 (1998) https://doi.org/10.1016/S0003-2670(98)00080-4
- Y. Miao and S. N. Tan, 'Amperometric Hydrogen peroxide Biosensor with Silica sol-gel/chitosan Film as Immobilization Matrix', Anal. Chim. Acta, 437, 87 (2001) https://doi.org/10.1016/S0003-2670(01)00986-2