Polydiacetylene-Based Chemo-/Biosensor of Label Free System with Various Sensing Tools

다양한 감지 방법을 갖고 있는 폴리디아세틸렌 기반 비표지 화학/바이오센서

  • Park, Hyun-Kyu (BioNanotechnoiogy Research Center, Korea Research Institute of Bioscience and Biotechnology) ;
  • Park, Hyun-Gyu (Department of Chemical and Biomolecular Engineering, Korea Advanced Institute of Science and Technology) ;
  • Chung, Bong-Hyun (BioNanotechnoiogy Research Center, Korea Research Institute of Bioscience and Biotechnology)
  • 박현규 (한국생명공학연구원 바이오나노연구단) ;
  • 박현규 (한국과학기술원 생명화학공학과) ;
  • 정봉현 (한국생명공학연구원 바이오나노연구단)
  • Published : 2007.12.31

Abstract

Polydiacetylene(PDA)-based sensors possess a number of properties that can be successfully applied for label-free detection system. PDA is one of the most attractive color-generating materials, with growing applications as sensors. Here we introduce various PDA-based devices, used as biosensor, chemosensor, thermosensor, and optoelectronics sensor. In general, PDA liposomes and films are closely packed and properly designed for polymerization via 1,4-addition reaction to form an ene-yne alternating polymer chain. PDA-based two/three dimensional structures have been used for colorimetric or fluorescent devices, sensing biological as well as chemical components. This color-generating material also present a very high charge carrier mobility, allowing its application as field-effect transistor (FET). The immobilized PDA structures or films have distinct advantages for the detection of low concentration target molecules over the aqueous solution-based detection systems. In the present review, reported detection methods by using various PDA structures are summarized with updated references.

양친성의 성질을 가진 폴리디아세틸렌 단량체를 이용한 센서는 주로 수용액 상태에서 리포좀이나 또는 다른 구조를 이용하였다. 폴리디아세틸렌은 수용액 상에서 쉽게 구조를 형성하는 장점과 여러 광학적인 특성을 가지고 있어서 다양한 목적물질의 검출을 가능하게 하였다. 디아세틸렌 단량체는 수 nm의 크기의 분자로서 LB 필름 제조 방법을 이용하면 아주 얇은 단분자층 또는 다분자층으로 필름을 형성할 수 있게 된다. 이렇게 형성된 필름은 수용액상에서 만들어진 구조체와 같은 성질을 가진다. 즉 무색으로 형성된 구조체들은 254 nm에 조사를 시키면 파란색으로 변하게 되며 650 nm 부근에서 최대 흡수 파장을 가지게 된다. 파란색으로 형성된 구조체는 다양한 외부환경 (온도, pH, 용매 등)이나 목적물질 (바이러스, 단백질, 항체, DNA, 펩타이드 등)의 결합으로 약하게는 보라색에서 강하게는 붉은색으로 변하게 된다. 색전이가 이루어진 수용액이나 필름에서는 파란색에서는 존재하지 않던 형광이 630 nm 부근에서 최대 방출 파장이 나타나기도 한다. 따라서 가시적인 방법이나 형광 검출 방법을 이용하면 색이 변한 정도에 따라 특이성의 정도를 결정할 수 있는 좋은 센서 기술이 될 것으로 사료된다. 목적 물질 검출에 대한 연구 이외에 대부분의 폴리디아세틸렌은 색전이가 이루어진 후 가역적인 현상을 보이지 않는다. 그러나 적절하게 치환된 관능기는 가역적인 성질을 부여하게 된다. 이런 성질들을 내포하면서 막대 모양과 같은 견고한 실리카 구조체의 형성에 적용할 수 있다는 연구 결과가 보고되고 있다. 그러나 구조체를 형성하는 단량체는 비특이적인 결합을 할 수 있는 관능기 (-COOH, $-NH_2$ 등)을 포함하고 있기 때문에 선택적인 센서의 개발을 위해서는 개선해야 할 부분이다. 결론적으로 보완된 다양한 구조체와 센서 적용 기술은 현재의 표지방식을 기반으로 하는 감지 기술을 대체할 수 있는 새로운 비표지 센서로의 적용이 가능할 것으로 여겨진다.

Keywords

References

  1. Moliton, A. and R. C. Hiorns (2004), Review of electronic and optical properties of semiconducting $\pi$-conjugated polymers: applications in optoelectronics, Polym. Int. 53, 1397-1412 https://doi.org/10.1002/pi.1587
  2. Okada, S., S. Peng, W. Spevak, and D. Charych (1998), Color and Chromism of Polydiacetylene Vesicles, Acc. Chem. Res. 31, 229-239 https://doi.org/10.1021/ar970063v
  3. Reppy, M. A. and B. A. Pindzola (2007), Biosensing with polydiacetylene materials: structures, optical properties and applications, Chem. Comm., 4317-4338
  4. Su, Y. -L., J. -R. Li, and L. Jiang (2004), Chromatic immunoassay based on polydiacetylene vesicles, Colloids Surfaces B 38, 29-33 https://doi.org/10.1016/j.colsurfb.2004.08.010
  5. Pan, J. J. and D. Charych (1997), Molecular recognition and colorimetric detection of cholera toxin by poly(diacetylene) liposomes incorporating Gml ganglioside, Langmuir 13, 1365-1367 https://doi.org/10.1021/la9602675
  6. Charych, D., Q. Cheng, A. Reichert, G. Kuziemko, M. Stroh, J. O. Nagy, W. Spevak, and R. C. Stevens (1996), A 'litmus test' for molecular recognition using artificial membranes, Chem. Biol. 3, 113-120 https://doi.org/10.1016/S1074-5521(96)90287-2
  7. Kolusheva, S., R. Kafr, M. Katz, and R. Jelinek (2001), Rapid colorimetric detection of antibody-epitope recognition at a biomimetic membrane interface, J. Am. Chem. Soc. 123, 417-422 https://doi.org/10.1021/ja0034139
  8. Kolusheva, S., T. Shahal, and R. Jelinek (2000), Peptide-membrane interactions studied by a new phospholipidjpoly diacetylene colorimetric vesicle assay, Biochemistry 39, 15851-15859 https://doi.org/10.1021/bi000570b
  9. Jung, Y. K., H. G. Park, and J. -M. Kim (2006), Polydiacetylene (PDA)-based colorimetric detection of biotin-streptavidin interactions, Biosens. Bioelectron. 21, 1536-1544 https://doi.org/10.1016/j.bios.2005.07.010
  10. Su, Y. -L. (2005), Assembly of polydiacetylene vesicles on solid substrates, J. Colloid Interl Sci. 292, 271-276 https://doi.org/10.1016/j.jcis.2005.05.049
  11. Kim, J. -M, Y. B. Lee, D. H. Yang, J. -S. Lee, G. S. Lee, and D. 1. Ahn (2005), A polydiacetylene-based fluorescent sensor chip, J. Am. Chem. Soc. 127, 17580-17581 https://doi.org/10.1021/ja0547275
  12. Cui, Y., Q. Wei, H. Park, and C. M. Lieber (2001), Nanowire nanosensors for highly sensitive and selective detection of biological and chemical species, Science 293, 1289-1292 https://doi.org/10.1126/science.1062711
  13. Manaka, T., H. Kohn, Y. Ohshima, E. Lim, and M. Iwamoto (2007), Direct observation of trapped carriers in polydiacetylene films by optical second harmonic generation, Appl. Phys. Lett. 90, 171119-1-171119-3 https://doi.org/10.1063/1.2734469
  14. Aleshin, A. N., S. W. Chu, V. I. Kozub, S. W. Lee, J. Y. Lee, S. H. Lee, D. W. Kim, and Y. W. Park (2005), Non-Ohmic conduction in polydiacetylene thin films, Curr. Appl. Phys. 5, 85-89 https://doi.org/10.1016/j.cap.2003.11.087
  15. Peng, T., Q. Cheng, and R. C. Stevens (2000), Amperometric detection of Escherichia coli heat-labile enterotoxin by redox diacetylenic vesicles on a sol-gel thin-film electrode, Anal. Chem. 72, 1611-1617 https://doi.org/10.1021/ac990406y