DOI QR코드

DOI QR Code

Estimation of Visual Stimulus Intensity From Retinal Ganglion Cell Spike Trains Using Optimal Linear Filter

최적선형필터를 이용한 망막신경절세포 Spike Train으로부터의 시각자극 세기 변화 추정

  • Ryu, Sang-Baek (Department of Biomedical Engineering, College of Health Science and Yonsei Medical Engineering Institute, Yonsei University) ;
  • Kim, Doo-Hee (Department of Biomedical Engineering, College of Health Science and Yonsei Medical Engineering Institute, Yonsei University) ;
  • Ye, Jang-Hee (Department of Physiology, Chungbuk National University Medical School) ;
  • Kim, Kyung-Hwan (Department of Biomedical Engineering, College of Health Science and Yonsei Medical Engineering Institute, Yonsei University) ;
  • Goo, Yong-Sook (Department of Physiology, Chungbuk National University Medical School)
  • 류상백 (연세대학교 보건과학대학 의공학과, 연세의료공학연구원) ;
  • 김두희 (연세대학교 보건과학대학 의공학과, 연세의료공학연구원) ;
  • 예장희 (충북대학교 의과대학 생리학교실) ;
  • 김경환 (연세대학교 보건과학대학 의공학과, 연세의료공학연구원) ;
  • 구용숙 (충북대학교 의과대학 생리학교실)
  • Published : 2007.04.30

Abstract

As a preliminary study for the development of electrical stimulation strategy of artificial retina, we set up a method fur the reconstruction of input intensity variation from retinal ganglion cell(RGC) responses. In order to estimate light intensity variation, we used an optimal linear filter trained from given stimulus intensity variation and multiple single unit spike trains from RGCs. By applying ON/OFF stimulation(ON duration: 2 sec, OFF duration: 5 sec) repetitively, we identified three functional types of ganglion cells according to when they respond to the ON/OFF stimulus actively: ON cell, OFF cell, and ON-OFF cell. Experiments were also performed using a Gaussian random stimulus and a binary random stimulus. The input intensity was updated once every 90 msec(i. e. 11 Hz) to present the stimulus. The result of reconstructing 11 Hz Gaussian and binary random stimulus was not satisfactory and showed low correlation between the original and reconstructed stimulus. In the case of ON/OFF stimulus in which temporal variation is slow, successful reconstruction was achieved and the correlation coefficient was as high as 0.8.

Keywords

References

  1. R. Eckmiller, D. Neumann, O. Baruth, 'Tunable retina encoders for retina implant: why and how,' J. Neural Eng., vol. 2, pp.s91-s104, 2005 https://doi.org/10.1088/1741-2560/2/1/011
  2. R. A. Normann, E. M. Maynard, P. J. Rousche, D. J. Warren, 'A neural interface for a cortical vision prosthesis,' Vision Res., vol. 39, Issue. 15, pp.2577-2587, 1999 https://doi.org/10.1016/S0042-6989(99)00040-1
  3. E. Zrenner, 'Will retianl implants restore vision?,' Science, vol. 295, pp.1022-1025, 2002 https://doi.org/10.1126/science.1067996
  4. F. J. Pelayo, S. Romeo, C. A. Morillas, A. Martinez, E. Ros, E. Fernandez, ' Translating image sequences into spike patterns for cortical neuro-stimulation,' Neurocomp., vol. 58-60, pp.885-892, 2004
  5. J. F. Rizzo, J. Wyatt, J. Loewenstein, S. Kelly, D. Shire, 'Methods and perceptual thresholds for short-term electrical stimulation of human retina with microelectrode arrays,' Invest. Ophthalmol., vol. 44, no. 12, pp.5355-5361. 2003 https://doi.org/10.1167/iovs.02-0819
  6. L. B. Merabet, J. F. Rizzo, A. Amedi, D. C. Somers, A. Pascual-Leone, 'What blindness can tell us about seeing again: merging neuroplasticity and neuroprosthesis,' Nat. Rev. Neurosci., vol. 6, pp.71-77, 2005 https://doi.org/10.1038/nrn1586
  7. D. K. Warland, P. Reinagel, M. Meister, 'Decoding visual information from a population of retinal ganglion cells,' J. Neurophysiol., vol. 78, pp.2336-2350, 1997 https://doi.org/10.1152/jn.1997.78.5.2336
  8. K. H. Kim, S. S. Kim, S. J. Kim, 'Superiority of nonlinear mapping in decoding multiple single-uni neuronal spike trains: a simulation study,' J. Neurosci. Methods, vol. 150, Issue. 2, pp.202-211, 2006 https://doi.org/10.1016/j.jneumeth.2005.06.015
  9. H. S. Cho, G. H. Jin, Y. S. Goo, 'Characterization of rabbit retinal ganglion cells with multichannel recording,' Korean J. Med. Phys., vol. 15, no. 4, pp. 228-236, 2004
  10. H. K. Hartline, 'The response of single optic nerve fibers of the vertebrate eye to illumination,' Am. J. Physiol., vol. 121, pp.400-415, 1938
  11. E. J. Chichilnisky, R. S. Kalmar, 'Functional asymmetries ON and OFF ganglion cells of primate retina,' J. Neurosci., vol. 22, no. 7, pp.2737-2747, 2002 https://doi.org/10.1523/JNEUROSCI.22-07-02737.2002