Theoretical Analysis on the Applications of the Double-Floor Ondol System

이중 바닥 온돌 시스템의 응용에 관한 이론적 분석

  • Published : 2007.05.10

Abstract

The Korean traditional 'Ondol' system has been a target for innovation to meet the requirements of sustainable domestic building and low carbon emission energy utilization. Simulation techniques provide designers and researchers with powerful tools to predict heating load and thermal behaviour of Ondol systems installed in various contexts. However, there are few studies on Ondol models, especially associated with multi-stories buildings of which type covers about 50% of Korean housing stock. In this study, we analyzed the double floor Ondol system on the multi-stories buildings using the ESP-r program. On the basis of the double floor Ondol system, we suggested the new modelling method that is composed of the Vent zone and Ondol zone. Using the this model, sensitivity analysis was carried out to refine the applicability of the model taking account of control conditions, constructions, air change and air flow network method and CFD analysis using the FLUENT. The air layer has enough temperature to use in heating zone. It is suggested that the simplicity of the model will allow building designers and mechanical engineers easily to implement scenario-based assessments of design options as well as control strategies. Later, we will simulate the real buildings and analyze the air distributions using the Fluent according to the various conditions.

Keywords

References

  1. Korean National Statistical Office, 2000, The census of population and residence, Report of reference 2000, pp.44-45
  2. Kang, J. S. and Choi, G. S., 2005, Multifunctional smart floor system for open-housing, Magazine of the SAREK, Vol. 34, No.8, pp.43-57
  3. Kang, J. S., Choi, G. S. and Lee, S. E., 2004, The thermal characteristic of IHCS (Infill heating & cooling system) radiant floor heating system, Proceeding of Annual Conference in AIK, Vol. 24, No. 24
  4. Park. S. H., Kim, J. Y., Park B. Y. and Sohn, J. Y., 2001, Development of the prefab ondol system using plate glass, Korea Journal of AIK, Vol. 21, No.2
  5. Choi, D. H., Kim, N. H. and Sohn, J. Y., 2004, The indoor thermal environment and characteristics of the dry double floor hydronic ondol system, Proceeding of Annual Conference in AIK, Vol. 24, No. 1
  6. Yee, J. J., Kim, Y. K. and Choi, S. Y., 2005, A performance evaluation on the prefabricated floor heating system using thermo siphon type heat pipe, Journal of the architectural institute of Korea planning & design, Vol. 21, No.3
  7. Shin, U. C., Jang, M. S., Yoo, H. H. and Min, J. H., 2002, Characteristics of heat transfer in the apartment with ondol heating system, Journal of the architectural institute of Korea planning & design, Vol. 18, No. 1
  8. Kang, J. S. and Cho, D. W., 1998, Evaluation and improvement for thermal performance of ondol heating structure in apartment housing, Proceeding of Annual Conference in AIK, Vol. 17, No. 1
  9. Choi, W. K., Lee, K. Y., Cha, D. W. and Suh, S. J., Theoretical analysis on the applications of the smart floor system, Proceedings of the SAREK 2006 winter annual conference
  10. Kamel Haddad, July 2002, ESP-r/HOT3000 : RADTEST - Radiant heating and cooling test cases, IEA, pp. 78-83
  11. Clarke, J. A., 2001, Energy Simulation in Building Design 2nd, Butterworth - Heinemann, pp.256-261
  12. Yoo, H., Hyun, S. K., Park, Y. W., Kim, Y. S. and Hong, H. K., 2004, Analysis of heating energy in a korean-style apartment building 1 : The effect of location, Proceeding of Annual Conference in SAREK, Vol. 16, No. 1, pp. 101-110
  13. Yoon, J. H., Yoon, H. K., Kang, D. H. and Choi, Y. D., 1992, Improvement of efficiency of floor radiant heating system with hot water for apartment buildings, Proceeding of Annual Conference in AIK, Vol. 8, No.1
  14. Cho, K. H., Kim, Y. I. and Seok, H. T., 1992, A study on the thermal performance improvement of prefab-ondol system by numerical simulation, Proceeding of Annual Conference in AIK, Vol. 8, No. 105
  15. Yeo, M. S. and Kim, K. W., 1999, A study on the control methods of hydronic radiant floor heating systems in apartment buildings, Proceeding of Annual Conference in AIK, Vol. 15, No.3
  16. Leigh, S. B. and Won, J. S., 2005, An evaluation of energy performance of radiant floor cooling and heating systems, Journal of the architectural institute of Korea planning & design, Vol. 21, No. 3