The Study of Reclaimer of Antiseptic Solution for Winter-sowing Prevention of a Vehicle Disinfector at Livestock Farm

축산농가 차량소독기의 동파방지를 위한 약액 회수장치에 관한 연구

  • Kim, W. (Major of Bio-industry Mechanical Engineering, Kongju Univ.) ;
  • Lee, S.K. (Major of Bio-industry Mechanical Engineering, Kongju Univ.)
  • 김웅 (공주대학교 생물산업기계공학) ;
  • 이승기 (공주대학교 생물산업기계공학)
  • Published : 2007.04.30

Abstract

This study was conducted to develop a reclaimer of the vehicle disinfector to be used at livestock fm. The reclaimer was mainly consisted of ball-valves, geared motors and one-chip processor, and the purpose of the system was to prevent liquid freezing as well as decrease environmental pollution of antiseptic solution. The properly spraying pressure of the vehicle disinfector was found over 1.96 MPa at 1m of the spraying range. While certain amount of the antiseptic solution remained in the injection-pipes, the spray starting time was found not making any significant effect on the remained amount of the antiseptic solution. The amounts of the antiseptic solution remained in the injection-pipes were 50 ml and 270 ml in average, respectively with and without the use of the reclaimer. The reclaimer was the most effective when the connection of the injection-pipe and sprayer line was located below the side-injection-pipe and then connected to the injection-pipe located at the bottom of vehicles.

Keywords