Durability Evaluation of ER Fluids in Hydraulic Control Systems

유압제어시스템 적용을 위한 ER 밸브의 내구성 평가

  • 김도태 (경일대학교 기계자동차학부) ;
  • 장성철 (삼원기술(주) 기술연구소)
  • Published : 2007.04.15

Abstract

Electro-rheological(ER) fluid and valve are fabricated and evaluated experimentally in its durability to utilize the hydraulic control systems for long term operation. The two-ports ER valve used in the experiment consist of twelve parallel multi-layer electrodes and provide a restriction to the passage of ER fluid because of the viscous pressure drop and a component induced by the electric field. The durability test of ER valve are performed by measuring the surface roughness of electrodes with variation of an electric field strength and test time(1000 or 1800min.). Also, the shear stress and shear rate are measured to evaluate the durability of ER fluid as function of time. After durability test, ER shear stress increases approximately proportional to the shear rate with applied electric field intensity, In the ER valve, the center line average height roughness(Ra) of copper electrode increases about 1.56 times and ten-point median height roughness(Rz) increases about 2.2 times after the durability test. An understanding of these durability is essential to predicting the service life of ER fluid and valves.

Keywords

References

  1. Jang, S. C. and Yum, M. O., 2004, 'Design and Performance Test of Valve Operated by ER Fluids,' Transactions of Korean Society of Machine Tool Engineers, Vol. 13, No. 1, pp. 63-68
  2. Jang, S. C., Yum, M. O. and Kim, D. T., 2003, 'Flow Rate-Pressure Drop Characteristics of Dispersive ER Fluid According to Change of Electric Field Strength in Clearance between Parallel Plates,' Transactions of Korean Society of Machine Tool Engineers, Vol. 12, No. 1, pp. 78-83
  3. Yokota, S. and Kondoh, Y. 1996, 'A Control valve by Making use of an ER Fluid,' JSME, Vol. 62, No. 601, pp. 93-100 https://doi.org/10.1299/kikaib.62.93
  4. Strandrud, H. T., 1966, 'Electric-field valves inside cylinder control vibrator,' Hydraulics and Pneumatics, pp. 139-143
  5. Lingard, S. and Bullough, W. A., 1989, 'Tribological Aspects of Electro-Rheological Fluid Behaviour with Respect to Non-Polar Base Liquids,' Proceedings of the Second International Conference on ER Fluids, pp. 158-175
  6. Sung, K. G., Chung, D. D. and Choi, S. B., 2001, 'Control of Automatic Cargo Handling System Using ER Valves(I),' Journal of the Korean Society of Precision Engineering, Vol. 18, No. 9, pp. 53-60