DOI QR코드

DOI QR Code

수경재배 시 다량 이온 농도 측정을 위한 이온 선택성 전극의 응용

Application of Ion-Selective Electrodes to Measure Ionic Concentrations of Macronutrients in Hydroponics

  • Kim, Min-Su (School of Biosystems Engineering, Seoul National University) ;
  • Park, Tu-San (School of Biosystems Engineering, Seoul National University) ;
  • Cho, Seong-In (School of Biosystems Engineering, Seoul National University)
  • 발행 : 2007.02.25

초록

This study was carried out to investigate the applicability of PVC membrane-based ion-selective electrodes for macronutrients (K, Ca, and N) by measuring of potassium, calcium, nitrate ions in hydroponic nutrient solution. The capabilities of two ion-selective membranes with varying chemical compositions for each ion were evaluated in terms of sensitivity, selectivity, and lifetime to choose sensing elements suitable for measuring typical ranges of nutrient concentrations in hydroponic solutions. The selected calcium and nitrate ion-selective membranes showed effectively sensitive responses to calcium and nitrate ions with lifetimes of 25 and 15 days, respectively. The addition of a cation additive to the potassium membrane cocktail allowed its sensitivity to be increased whereas its lifetime was reduced from 30 days to 10 days.

키워드

참고문헌

  1. Ammann, D., P. Anker, E. Metzger, U. Oesch, W. Simon, M. Kessler, D.K. Harrison and J. Hoper. 1985. Neutral carrier based silicone rubber membranes for $H_3O^+,\;K^+$, $NH_4^+$ and $Ca^{2+}$ selective electrodes. Springer-Verlag, Berlin, Heidelberg, pp.102
  2. Bae, Y. M. and S. I. Cho. 2002. Response of polymer membranes as sensing elements for an electronic tongue. Trans. ASAE 45(5):1511-1518
  3. Campanello, L., C. Colapicchioni, R. Crescenti M.P. Sarnmartino, Y. Su and M. Tomassetti. 1995. Sensitive membrane ISFETs for nitrate analysis in waters. Sens. Actu. B27(1-3):329-335
  4. Craggs, A., G. J. Moody and J. D. R. Thomas. 1974. PVC matrix membrane ion-selective electrodes. J. of Chem. Educ. 51(8):541-544 https://doi.org/10.1021/ed051p541
  5. Deyhimi, F. 1999. A method for the determination of potentiometric selectivity coefficients of ion selective electrodes in the presence of several interfering ions. Talanta 50:1129-1134 https://doi.org/10.1016/S0039-9140(99)00194-0
  6. Didina, S., L. Mitnik, N. Koshmina, A. Grekovich and K. Mikhelson. 1994. Lead-selective electrodes based on liquid ion-exchangers. Sens. Actu. B19(1-3):396-399
  7. Hong, U. S., H. K Kwon, G. S. Cha, H. H. Nam, S. H. Chang and K. B. Chung. 1995. Benzothiazole substituted benzocrown ether-based potassium ion-selective membrane electrodes. J. of the Korean Chem. Soc. 39(9):698-704. (In Korean)
  8. Kim, G. Y. 2003. Application of a strip ion-selective electrode sensor for hydroponic nutrient solution analysis - $NO_3^-$ analysis. J. of the Korean Soc. for Agricultural Machinery 28(4):335-342. (In Korean) https://doi.org/10.5307/JBE.2003.28.4.335
  9. Kim, H. J., J. W. Humrnel, and S. J. Birrell. 2006. Evaluation of nitrate and potassium ion-selective membranes for soil macronutrient sensing. Trans. ASABE 49(3):597-606 https://doi.org/10.13031/2013.20476
  10. Kim, M. K., K. H. Ryu, Y. S. Jang, and G. Y. Kim. 2002. Study on automatic mixing of nutrient solution using ion electrodes for closed-loop hydroponics. J. of the Korean Soc. for Agri. Machinery 27(5):425-432. (In Korean) https://doi.org/10.5307/JBE.2002.27.5.425
  11. Knoll, M., K. Cammann, C. Dumschat, M. Borchardt and G. Hogg. 1994. Microfibre matrix-supported ion-selective PVC membranes. Sens. Actu. B20(1):1-5
  12. Lee, H. L. 1986. Ion-selective electrodes. The magazine of the IEEK 13(1):36-43. (In Korean)
  13. Moody, G. J. 1985. Mechanistic studies of ion-selective electrodes. J. of Biom. Engi. 7(3):183-195 https://doi.org/10.1016/0141-5425(85)90019-6
  14. Ruzicka, J., E. Hansen and J. Tjell. 1973. The calcium selectrode employing a new ion exchanger in a nonporous membrane and a solid-state reference system. Anal. Chim. Acta 67:155- 178 https://doi.org/10.1016/S0003-2670(01)80243-9
  15. Wegmann, D., H. Weiss, D. Ammann, W.E. Morf, E. Pretsch, K. Sugahara and W. Simon. 1984. Anion-selective liquid membrane electrodes based on lipophilic quaternary ammonium compounds. Microchim. Acta 84(1-2):1-16 https://doi.org/10.1007/BF01204153