DOI QR코드

DOI QR Code

An Evaluation of Aerobic Exercise Wear Mobility as a Basic Criterion for Universal Design

에어로빅복의 유니버설 디자인을 위한 동작 적합성 평가

  • Sohn, Ju-Hee (Research Institute of Human Ecology, Seoul National University) ;
  • Choi, Jeong-Wha (College of Human Ecology, Seoul National University/Research Institute of Human Ecology, Seoul National University) ;
  • Kang, Tae-Jin (School of Materials Science and Engineering, Seoul National University)
  • 손주희 (서울대학교 생활과학연구소) ;
  • 최정화 (서울대학교 의류학과/생활과학연구소) ;
  • 강태진 (서울대학교 재료공학부)
  • Published : 2007.03.31

Abstract

This study compared and studied the clothing mobility of two types of aerobic clothes - those made of currently popular stretch materials and those made of new stretch materials that were specially developed for this study. The focus of the comparison was on the range of joint movement during activity, and the physiological burden imposed on the body by the clothes. In total, 18 experiments were carried out under controlled conditions in an artificial climatic chamber with a temperature of $25{\pm}1^{\circ}C$, air humidity of $60{\pm}5^{\circ}C$ and negligible air movement. Each exercise program consisted of a 30-minute of aerobic workout and a 20-minute rest following the exercise. Measurements were taken to determine the following: physiological reactions (whole-body and local sweat rates), subjective sensations(of temperature, humidity, comfort, tightness, and clothing wetness), joint angle(measured with a goniometer), and so on. The results of the study us as follows: Material B excels in clothing mobility. Material C excels in sweat absorbency and drying speed. Material A was found to be the hottest material, while material C was found to be slightly hot through the analysis of the change in pre- and post-exercise bodyweight(= amount of sweat). Regarding the amount of evaporated sweat, material A>material C>material B. Material B produced the smallest amount of evaporated sweat. The wider the range of joint movement, the smaller the amount of sweat and the lower the average skin temperature.

Keywords

References

  1. 김민자, 최정화. (2004). 한국적 이미지의 에어로빅복 디자인 개발에 관한 연구. 한국의류학회 추계학술대회초록집, 75
  2. 김영희. (2003). 의복의 기능성 측정을 위한 관절각도법에 관한 비교연구. 한국의류학회지, 27(12), 1374-1380
  3. 재단법인 한국 에어로빅협회. (2004). AEROBICS PROGRAM GUIDE
  4. 최정화, 김민자, 박정희. (2004). 고기능성 스포츠 웨어전 우.리.얼. 국립중앙도서관 전시실, 8월24일-28일, 한국과학재단 특정기초연구, 기능성 스포츠웨어 산업 활성화를 위한 기초연구 최종보고 특별전-에어로빅 소재 평가, 46
  5. 한혜원, 김희은, 이경옥, 이유찬, 이기화 (2000). Aquarobics 운동이 여성의 체격, 체력, 신체구성에 미치는 영향. 한국체육학회지, 39(1),436-444
  6. 猪又美榮子. (2004). 衣服分野のユニバ-サルデザインに開する基礎的硏究. KAKEM(科学硏究費), 国立情報学硏究所, 자료검색일 2006, 8. 10, 자료출처 http://www nii.ac.jp/services/services-j.shtml
  7. 渡邊敬子. (2004). 被服のユニバ-サルデザインのための着脫動作の解釋. KAKEM(科学硏究費), 国立情報学硏究所, 자료검색일 2006,8.10,자료출처 http://www.nii.ac.jp
  8. 村田仁代. (2003). ユニバ-サル.ファッションの硏究開發動向および敎育內容に開する. 日米比較硏究, 日本科學硏究費補助金デ-タベ-ス, 国立情報学硏究所, 자료검색일 2006, 8. 10, 자료출처 http://seikanii.ac.jp
  9. 伊藤紀子. (2004). 異なる季節.地域におけるユニバ-サル.ファッション提案のための被服衛生学的究所. KAKEM(科學硏究費), 国立情報学硏究所, 자료검색일 2006, 8. 10, 자료출처 http://seikanii.ac.jp
  10. 古懶敏. (2003, 6). 月刊 ノ-マライゼ-ション Universal Design Network Japan. 자료검색일 2005, 10. 10, 자료 출처 http://www.udnj.org
  11. Biometrics Ltd. (2004). Biometrics Ltd.자료검색일 2004, 10. 10, 자료출처 http://www.biometricsltd.com
  12. Cynthia, C, Norkin, D., & Joyce White. (2002). 関節可動域測定法(改訂第2版), 木村哲彦 監譯. 日本: (株)協同醫書出版社
  13. NHK 敎育 TV. (2004). Let's fit aerobics. 日本: 日本放送出版協會