Monitoring of Lead and Antimony in Metallic Kitchenware

국내 유통 금속제 주방기구 중 납 및 안티몬 모니터링

  • 이선희 (한국생활환경시험연구원) ;
  • 정규진 (한국생활환경시험연구원) ;
  • 이융국 (한국생활환경시험연구원) ;
  • 성준현 (식품의약품안전청 용기포장팀) ;
  • 엄미옥 (식품의약품안전청 용기포장팀) ;
  • 이영자 (식품의약품안전청 용기포장팀) ;
  • 임종균 (한국생활환경시험연구원)
  • Published : 2007.03.30

Abstract

In order to offer monitoring data about standard and specification of metallic kitchenware, we carried out the material test and migration test of lead and antimony in 71 kinds of kitchenwares. As a result of this study, Pb was detected less than 0.06% at the material test and Sb was not defected in 71 kinds of kitchenwares. Pb was also detected less than 0.41 mg/L at the migration test. Currently according to the Food Code of Korea, Pb and Sb in metal product shall not exceed 10% and 5%, respectively and Pb migrated from metal product shall not exceed 1.0 mg/L. Therefore, our all data are not exceeding the standard and specification of metal product and show that all the kitchenwares in domestic circulation may be safe.

본 연구는 국내 유통 중인 프라이팬, 냄비, 주전자, 불판 등 금속제 주방기구 총 71품목을 대상으로 안전성 및 오염 정도에 대한 기초 자료를 제공하고자 실시되었다. 현행 식품공전 금속제의 재질 규격은 Pb 10%, Sb 5%이하이며 용출 규격은 Pb 1.0 mg/L이하이다. 알루미늄, 스테인리스 및 주철 총 71품목의 금속제 주방기구에 대한 재질시험 결과 Pb은 0.06% 이하로 검출되었으나 기준이하였으며 Sb은 모든 제품에서 검출되지 않았다. 또한 이들 주방기구의 용출시험 결과에서도 기준치이하인 0.41mg/L의 Pb이 검출되어 국내 유통 중인 금속제 주방기구는 기준규격에 적합한 것으로 나타났다.

Keywords

References

  1. 이광호, 권기성, 곽인신, 전대훈, 최병희, 유승석, 김성욱, 이 선희 : 금속제 기구 및 용기포장의 유해물질에 관한 조사연 구, The Annual Report of KFDA, 2, 126-139 (1998)
  2. Reilly, C : Metal Contamination of Food, Its Significance for Food Quality and Human Health, Blackwell Science, 3rd edition (2001)
  3. Agarwal. P., Srivastava, S., Srivastava, M.M., Prakash, S., Ramanamurthy, M., Shrivastav, R. and Dass, S. : Studies on leaching of Cr and Ni from stainless steel utensils in certain acids and in some Indian drinks, The Science of the Total Environment, 199, 271-275 (1997) https://doi.org/10.1016/S0048-9697(97)05455-7
  4. Samsahl, K. : Metallic contamination of food during preparation and storage: Development of methods and some preliminary results, The Science of the Total Environment, 8, 165-177 (1977) https://doi.org/10.1016/0048-9697(77)90075-4
  5. 최용욱 : 흐름주입분석법에 의한 주방용기로부터 용출된 알루미늄의 정량, 한국물환경학회지, 20(3), 281-289 (2004)
  6. Takeda, Y., Kawamura, Y. and Tamada, T. : Dissolution of Aluminum from Aluminum Foil Products in Food-Simulating Solvents, Journal of Food Hygienic Society of Japan, 39(3), 178-183 (1998) https://doi.org/10.3358/shokueishi.39.3_178
  7. Takeda, Y., Kawamura, Y. and Tamada, T. : Migration of Aluminium from Disposable Aluminium Foil Vessels into Foods, Journal of Food Hygienic Society of Japan, 40(2), 172- 177 (1999) https://doi.org/10.3358/shokueishi.40.172
  8. Stewsand, G.S., Stamer, J.R., Kosikowski, F.V., Morse, R.A and Lisk, D.J. : Cr and Ni in acidic food and by product containing stainles steel during processing, Environ. Contam. Toxicol, 21, 600-603 (1979) https://doi.org/10.1007/BF01685476
  9. Inoue, I., Ishiwala, H. and Yoshihira, K. : Aluminium levels in food simulating solvents and various foods cooked in Al pans, J. Agric. Food Chem. 36, 599-601 (1988) https://doi.org/10.1021/jf00081a048
  10. 원경풍 : 식품중의 미량금속에 관한 조사연구, The Annual Report of KFDA (1997)
  11. 비철금속재료와 열처리, 기전연구사 (2004)
  12. 철강재료, 희중당 (1994)
  13. 금속용어사전, 성안당 (2003)
  14. 식품공전 제6. 기구 및 용기篠汰揚 기준 및 규격, 식품의 약품안전청 (2005)