DOI QR코드

DOI QR Code

폴리머 피뢰기의 구조에 따른 온도와 누설전류 특성

Temperature and Leakage Current Characteristics of Polymeric Surge Arrester with Housing

  • 발행 : 2007.03.01

초록

In this paper, the ZnO surge arrester performance of power distribution class has been studied under different manufacturing conditions such as housing materials(polymeric, porcelain), interface sealants and one-body molding type. In the recent years, the polymeric ZnO surge arresters have been developed and put into operations based on their excellent characteristics. For polymeric surge arresters, the inner gas volume is extremely small, especially in solid insulation polymeric arresters there are not any gas volume inside arresters in the structure due to polymeric materials are filled into the internal gas volume. The sealing integrity is related to safe operation of surge arrester, the prime failure reason of porcelain housed arresters is moisture ingress. In this paper, the sealing integrity of polymeric surge arresters is investigated with moisture multi-aging test and ingress test. The evaluation techniques are used to inspect the sealing integrity of polymeric arresters, including leakage current, surface temperature, reference voltage and dissipation factor.

키워드

참고문헌

  1. L. M. Levinson and H. R. Philipp, 'Zinc oxide varistors-a review', Am. Ceram. Soc. Bull., Vol. 65, p. 639, 1986
  2. T. K. Gupta, 'Application of zinc oxide varistors', J. Am. Ceram. Soc., Vol. 73, p. 1817, 1990 https://doi.org/10.1111/j.1151-2916.1990.tb05232.x
  3. E. C. Sakshaug, 'A brief history of AC surge arrester', IEEE Power Eng. Review, No. 8, p. 11, 1991
  4. K. Lahti, B. Richter, K. Kannus, and K. Nousiainen, 'Behaviour of the DC leakage currents of polymeric metal oxide surge arresters in water penetration tests', IEEE Trans. on Power Delivery, Vol. 13, No. 2, p. 459, 1998 https://doi.org/10.1109/61.660915
  5. K. Lahti, B. Richter, K. Kannus, and K. Nousiainen, 'Internal degradation of polymer housed metal oxide surge arresters in very humid ambient conditions', IEEE High Voltage Engineering Symposium, 1999
  6. K. Lahti, K. Kannus, and K. Nousiainen, 'A comparison between the DC leakage currents of polymer housed metal oxide surge arresters in very humid ambient Conditions and in Water Immersion Tests', IEEE Trans. on Power Delivery, Vol. 14, No.1, p. 163, 1999 https://doi.org/10.1109/61.736709
  7. K. Lahti, K. Kannus, and K. Nousiainen, 'Diagnostic methods in revealing internal moisture in polymer housed metal oxide surge arresters', IEEE Trans. on Power Delivery, Vol. 17, No.4, p. 951, 2002 https://doi.org/10.1109/TPWRD.2002.803694
  8. J. H. He, S. W. Han, and H. G. Cho, 'Thermal properties of whole-solid insulated polymeric ZnO surge arrester', Electrical Insulation and Dielectric Phenomena. Conf., Vol. 3, p. 568, 1998