다양한 골질에서 임플랜트 수용부 형성방법이 임플랜트 1차 안정성에 미치는 영향

EFFECT OF PREPARATION METHODS OF RECIPIENT SITE ON PRIMARY IMPLANT STABILITY IN VARIOUS BONE QUALITIES

  • 최득철 (전남대학교 치의학전문대학원 치과보철학교실) ;
  • 방몽숙 (전남대학교 치의학전문대학원 치과보철학교실) ;
  • 오희균 (전남대학교 치의학전문대학원 구강악안면외과학교실)
  • Cui, De-Zhe (Department of Prosthodontic, College of Dentistry, Chonnam University) ;
  • Vang, Mong-Sook (Department of Prosthodontic, College of Dentistry, Chonnam University) ;
  • Oh, Hee-Kyun (Department of Oral & Maxillofacial Surgery, College of Dentistry, Chonnam University)
  • 발행 : 2007.08.31

초록

키워드

참고문헌

  1. Watzek G. Implants in qualitatively compromised bone. Quintessence pp67-94, 2005
  2. Albreksson T, Branemark PI. Osseointegrated titanium implants: Requirements for ensuring a long-lasting direct bone to implant anchorage in man. Acta Orthop Scand 1981:52:155-170 https://doi.org/10.3109/17453678108991776
  3. Lekholm U, Zarb GA. Patient selection and preparation. In : Branemark PI, Zarb GA : Aging, Osteoporosis. and clinical dentistry. Chicago, Quintessence pp67-84. 1985
  4. Watzek G, UIm C. Compromised alveolar bone quality in edentulous jaws. In: Zarb GA, Lekholm U. Albreksson T. Aging. Osteoporosis, and Dental Implants. Chicago: Quintessence pp67-84, 2002
  5. Park C, Cho IH. New technology for implant stability measurement. Dental Success 2000:10: 842-846
  6. Han JH, Heo SJ. Implant system selection for successful osseointegration. Dental Success 2000:10:943-951
  7. Glauser R. Sennerby L. Meridith N. Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading: successful vs.failing implants. Clin Implant Den ReI Res 2004:15:428-434
  8. Friberg B, Sennerby L, Johansson P, Strd KG, Lekholm U. Stability measurements of one stage Branemark implants during healing in mandibles: A clinical resonance frequency analysis study. In J oral Maxillofac Surg 1999: 28:266-272 https://doi.org/10.1016/S0901-5027(99)80156-8
  9. Johansson P, Sturd KG. Assessment of bone quality from cutting resistance during implant surgery. Int J Oral Maxillofac Implants 1994:9:279-288
  10. Friberg B, Sennerby L, Johansson P, Sturd KG, Lekholm U. Evaluation of bone density using cutting resistance measurements and microradiography: An in vitro study in pig ribs. Clin Oral Implants Res 1995:6:164-171 https://doi.org/10.1034/j.1600-0501.1995.060305.x
  11. Friberg B. Lekholm U. A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study. Int J Oral Maxillofac Surg 1999:28:297-303 https://doi.org/10.1016/S0901-5027(99)80163-5
  12. Drago CG. A prospective study to assess osseointegration of dental endosseous implants with the Periotest instrument. Int J Oral Maxillofac Implants 2000:15:389-395
  13. Caulier H, Kalk W. Jansen JA. The relationship of some histologic parameters. radiographic evaluations. and Periotest measurements of oral implants: An experimental animal study. Int J Oral Maxillofac Implant 1997:12:380-386
  14. Meredith N, Book K, Friberg B. Resonance frequency measurements of implants. stability in vivo: Pi cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Implants Res 1997:8:226-233 https://doi.org/10.1034/j.1600-0501.1997.080309.x
  15. Huang HM, Lee SY, Yeh CY, Lin CT. Resonance frequency assessment of dental implant stability with various bone qualities: A numerical approach. Clin Oral Implants Res 2002:13:65-74 https://doi.org/10.1034/j.1600-0501.2002.130108.x
  16. Truhlar RS, Lauciello F, Morris HF. The influence of bone quality on Periotest values of endosseous dental implants at stage II surgery. J Oral Maxillofac Surg 1997:55:55-61
  17. Mericske-Stern R, Milani D, Mericske E. Periotest measurements and osseointegration of mandibular ITI implants supporting overdentures. Clin Oral Implants Res 1995:6:73-82
  18. Meredith N. Assessment of Implant stability as prognostic determinant. Int. J Prosthodont 1998:11:491-501
  19. Lekholm U, Zarb GA. Patient selection and preparation. in Branemark PI. Zarb GA, Albrektsson T.(eds): Tissue integrated prostheses: Osseointegration in clinical dentistry. Chicago. Quintessence pp199-209. 1985
  20. Nkenke E. Hahn M. Weinzierl K. Implant stability and histomorphometry: a correlation study in human cadevers using stepped cylinder implants. Clin Implant Dent Rel Res 2003:14:601-609
  21. Derhami K, Worfaardt J, Dent M. Assessment of the Periotest device in baseline mobility measurements of craniofacial implants. Oral and Maxillofacial Implants 1995:10:221-229
  22. Meredith N. Assessment of Implant stability as prognostic determinant. Int J Prosthodont 1998:11:491-501
  23. Nkenke E, Kloss F, Wiltfang J, Schultze-Mosgau S, Radespiel-Troger M, Loos K, Neukam FW. Histomorphometric and fluorescence microscopic analysis of bone remodelling after installation of implants using osteotome technique. Clin Oral Implants Res 2002:13:595-602 https://doi.org/10.1034/j.1600-0501.2002.130604.x
  24. Olsson M. Urde G. Andersen JB. Early loading of maxillary fixed cross-arch dental prostheses supported by six or eight oxidized titanium implants: results after 1 year of loading. case series: Clin Implant Dent Rel Res 2003:5:81-85 https://doi.org/10.1111/j.1708-8208.2003.tb00019.x
  25. Teerlinck G, Quirynen M. Darius : Periotest an objective clinical diagnosis of bone apposition toward implants. Int J Oral Maxillofac Implants 1991:6:55-61
  26. Caulier H, Naert I, Kallk. The relationship of some histologic parameters. radiographic evaluations. and Priotest method as measurements of oral implants: An experimental animal study. Int J Oral Maxillofac Implants 1994:12:380-386
  27. Carr AB, Larsen PE, Papazoglou E. Reverse torque failure of screw-shaped implants in baboons: baseline date for abutment torque application. Int J Oral Maxillofac Implants 1995:10:167-174
  28. Summer RB. A new concept in maxillary implants surgery: The osteotome technique. Compend Contin Educ Dent 1994:15:152-158
  29. Glauser G, Naef R. The osteotome technique-A different method of implant placement in the posterior maxilla. Implantol 1998:2:103-120