Abstract
Experimental study was carried out to investigate the structural performance of composite beams with steel fiber concrete and angle. For this purpose, seven specimens composed of two RC beams with or without steel fiber and five composite beams with steel fiber and angle were constructed and tested. All specimens had no web shear reinforcement. Main variables for the specimens were tensile reinforcement ratio and fiber volume fraction. Based on the test results, structural performance such as strength, stiffness, ductility and energy dissipation capacity was evaluated and compared with the predicted strength. The prediction of flexure and shear strength gives a good relationship with the observed strength. The strength, ductility and energy dissipation capacity are increased, as the fiber volume fraction is increased. Meanwhile, high tensile reinforcement ratio resulted in the reduction of ductility and energy dissipation capacity for the composite beams.
본 연구는 강섬유 보강 콘크리트와 앵글을 사용한 합성보의 구조성능을 평가하고자 실험 연구를 수행하였다. 이러한 목적으로 일반 RC보와 강섬유가 혼입된 RC보, 그리고 강섬유 보강 합성보로 구성된 총 7개의 실험체를 제작하였으며, 모든 실험체에는 별도의 전단보강을 하지 않았다. 실험체의 주요 변수는 강섬유의 혼입률과 인장보강근비이며, 합성보의 강도 예측식의 평가와 실험 결과로부터 합성보의 강도, 강성, 연성능력, 에너지소산능력 등의 구조 성능을 평가하였다. 실험 결과들을 평가한 결과, 합성보의 공칭강도 산정식은 매우 정확한 예측이 가능하였으며, 휨균열강도 예측식은 강섬유 보강 효과의 고려가 필요하다고 판단되었다. 강섬유 체적비는 실험체의 강도와 연성 능력, 그리고 에너지소산 능력을 모두 증가시키는 것으로 나타났다. 인장보강근비와 유효인장보강근비의 증가는 실험체의 최대강도 증가에는 효과가 있지만, 반면에 연성 능력과 에너지소산 능력은 일정 수준을 초과하면 연성 능력과 에너지소산 능력이 저하하는 것으로 나타나고 있으므로 적절한 인장보강근비와 유효인장보강근비가 적용될 수 있도록 제한할 필요성이 있다고 판단된다.