Abstract
The assessment of shear wave velocity($V_s$) in soft soils is extremely difficult due to the soil disturbances during sampling and field access. After a ring type field $V_s$ probe(FVP) has been developed, it has been applied at the southern coastal area of the Korean peninsular. This study presents the upgraded FVP "blade type FVP", which minimizes soil disturbance during penetration. Design concerns of the blade type FVP include the tip shape, soil disturbance, transducers, protection of the cables, and the electromagnetic coupling between transducers and cables. The cross-talking between cables is removed by grouping and extra grounding of the cables. The shear wave velocity of the FVP is simply calculated by using the travel distance and the first arrival time. The large calibration chamber tests are carried out to investigate the disturbance effect due to the penetration of FVP blade and the validity of the shear waves measured by the FVP. The blade type FVP is tested in soils up to 30m in depth. The shear wave velocity is measured every 10cm. This study suggests that the upgraded blade type FVP may be an effective device for measuring the shear wave velocity with minimized soil disturbance in the field.
연약지반의 강성평가는 샘플링(sampling)과 현장 접근에 따른 교란으로 인해 정확하게 평가하는 것이 상당히 어렵다. 이를 위해 개발된 링 타입 FVP를 이용하여 부산 신항에서 실험이 수행 되었다. 이 논문의 목적은 지반 관입시 발생하는 교란을 최소화 할 수 있도록 기존의 링 타입 FVP를 블레이드 타입 FVP로 개량하는 것이다. 블레이드 타입 FVP는 하단의 웨지 모양, 시료 교란, 트랜스듀서, 케이블의 보호, 그리고 케이블과 트랜스듀서간의 전자기적 커플링을 고려하여 설계하였다. 케이블 간 누화현상은 케이블의 접지와 통합을 통해 제거 할 수 있었다. FVP의 전단파 속도는 초기 도달 시간과 이동거리를 이용하여 간단하게 계산될 수 있었다. FVP 블레이드의 관입에 의한 교란 효과 조사 및 FVP를 통해 측정된 전단파 속도의 타당성을 확인하기 위하여 실내 대형 calibration 챔버를 이용하여 비교 시험을 수행하였다. 블레이드 타입 FVP는 30m 깊이까지 측정이 되었으며, 전단파 속도는 매 심도 10cm마다 측정이 되었다. 본 논문에서 제시된 개량된 블레이드 타입의 FVP는 대상 지반의 교란을 최소화 시키며 현장에서 직접 전단파 속도를 측정 할 수 있는 효과적인 장비라고 할 수 있다.