DOI QR코드

DOI QR Code

동시 다중 주사 방식의 초음파 합성구경 빔포머 구조

Ultrasound Synthetic Aperture Beamformer Architecture Based on the Simultaneous Multi-scanning Approach

  • Lee, Yu-Hwa (Department of Electronic Engineering, Sogang University) ;
  • Kim, Seung-Soo (Department of Electronic Engineering, Sogang University) ;
  • Ahn, Young-Bok (Department of Electronic Engineering, Konkuk University) ;
  • Song, Tai-Kyong (Department of Electronic Engineering, Sogang University)
  • 발행 : 2007.12.31

초록

Although synthetic aperture focusing techniques can improve the spatial resolution of ultrasound imaging, they have not been employed in a commercial product because they require a real-time N-channel beamformer with a tremendously increased hardware complexity for simultaneous beamforming along M multiple lines. In this paper, a hardware-efficient beamformer architecture for synthetic aperture focusing is presented. In contrast to the straightforward design using NM delay calculators, the proposed method utilizes only M delay calculators by sharing the same values among the focusing delays which should be calculated at the same time between the N channels for all imaging points along the M scan lines. In general, synthetic aperture beamforming requires M 2-port memories. In the proposed beamformer, the input data for each channel is first upsampled with a 4-fold interpolator and each polyphase component of the interpolator output is stored into a 2-port memory separately, requiring 4M 2-port memories for each channel. By properly limiting the area formed with the synthetic aperture focusing, the input memory buffer can be implemented with only 4 2-port memories and one short multi-port memory.

키워드

참고문헌

  1. A.Macovski, Medical Imaging Systems, Prentice Hill, 1983, pp.73-224
  2. James A. Zagzebski, Essentials of Ultrasound Physic, Mosby-Year Book, Inc., 1996
  3. T. K. Song and S. B. Park, 'A new digital array system for dynamic focusing and steering with reduced sampling rate,' Ultrasonic Imaging, vol. 12, pp.1-16, 1990 https://doi.org/10.1016/0161-7346(90)90217-L
  4. M. O'Donnell, 'Efficient parallel receive beam forming for phased array imaging using phase rotation,' 1990 IEEE Ultrasonics Symposium, pp.1495-1498, 1990
  5. M. O'Donnell, etc, 'Real-time phased array imaging using digital beam forming and autonomous channel control,' 1990 IEEE Ultrasonics Symposium, pp.1499-1502, 1990
  6. Jeong M. K., et al., 'Generation of sinc wave by a one dimensional array for applications in ultrasonic imaging,' IEEE Trans. UFFC, vol. 43, no. 2, pp.285-295, 1996 https://doi.org/10.1109/58.485955
  7. A. Drukarev, K. Konstantinides, and G. Seroussi, 'Beam transformation techniques for ultrasonic medical imaging,' IEEE Trans. UFFC, vol. 40, no. 6, pp.717-726, 1993 https://doi.org/10.1109/58.248216
  8. P. D. Corl, G. S. Kino, C. S. Desilet, and P. M. Grant, 'A digital synthetic focus imaging system,' Acoustical Holography, New York: plenum, vol. 8, pp. 39-53, 1980
  9. J. T. Ylitalo and H. Ermert, 'Ultrasound synthetic aperture imaging: monostatic approach,' IEEE Trans. UFFC, vol. 41, no. 3, pp.333-339, 1994 https://doi.org/10.1109/58.285467
  10. M. Karaman, H. S. Bilge, and M. O'Donnell, 'Adaptive multi-element synthetic aperture imaging with motion and phase aberration correction,' IEEE Trans. UFFC, vol. 45, no. 4, pp. 1077-1087, 1998 https://doi.org/10.1109/58.710591
  11. T. K. Song, 'Analysis of synthetic aperture techniques for ultrasound linear-scan imaing,' J. of Biomed. Eng. Res., vol. 20, no. 4, pp. 503-513, 1999
  12. M. Karaman, P. C. Li, and M. O'Donnell, 'Synthetic aperture imaging for small scale systems,' IEEE Trans. UFFC, vol. 42, pp.429-442, 1995 https://doi.org/10.1109/58.384453