Abstract
Chromatic device was developed using light emitting diodes, optic fibers and photodiodes. Chromatic ratio and total contamination parameters based on transmitted light intensity in Red, Green, and Blue wavelengths were used for oil chemical and particulate contamination assessment. Chromatic ratio criterion was found independent of the particulate contamination of oil; but depended on chemical degradation, being more sensitive for synthetic than mineral hydraulic oil. Total contamination index of the sensor depended on both the chemical degradation and particulate contamination of the oil; being most sensitive in blue wavelength, and least in the red. Test results for synthetic hydraulic oils monitored corroborated with results of other tests such as viscosity, total acid number, elemental optical emission spectroscopy, particulate counts and UV-VIS photospectrometry. Chromatic ratio showed a clearer indication of oil degradation, compared to key monitoring parameters such as total acid number, viscosity and particle counts. The results showed that these parameters are effective criteria for the condition monitoring of synthetic hydraulic oils.