References
- V.L. Snoeyink and D. Jenkins, (eds.), Water Chemistry, John Wiley and Sons, Inc, New York, 1980
- J.R. Kirk and S.K. Mitchell In: R.L. Jolley, W.A. Brungs, and R.B. Cunnning, Editors, Risks and Benefits Associated with Chlorine in the Food Industry, in Water Chlorination: Environmental Impact and Health Effects, vol. 3, Ann Arbor Science, Ann Arbor, 1980
- APHA, American Public Health Association Standard Method 6420, Standard methods for the examination of water and wastewater, 20th ed., APHA, Washington, 1999
- H. Kim, J. Shim, and S. Lee, 'Formation of disinfection by-products in chlorinated swinnning pool water', Chemosphere, vol. 46, no. 1, pp. 123-130, 2002 https://doi.org/10.1016/S0045-6535(00)00581-6
- K. Howard and T.J.J. Inglis, 'The effect of free chlorine on Burkholderia pseudomallei in potable water', Water Res, vol. 37, no. 18, pp. 4425-4432, 2003 https://doi.org/10.1016/S0043-1354(03)00440-8
- G.C. White, Handbook of Chlorination, 2nd ed., Van Nostrand Reinhold Co. Inc., New York, 1986
- A. Griset, M. Archenault, P. Lacombe, and G. Mondin, 'Integrated chlorine sensor for drinking water distribution security system', Analyst, vol. 22, pp. M13-M15, 1994
- B. Saad, W.T. Wai, S. Jab, W.S.W. Ngah, M.I. Saleh, and J.M. Slater, 'Development of flow injection spectrophotometric methods for the determination of free available chlorine and total available chlorine: comparative study', Anal. Chim. Acta, vol. 537(1-2), pp. 197-206, 2005 https://doi.org/10.1016/j.aca.2005.01.055
- F. Javier Del Campo, O. Ordeig, and F. Javier Munoz, 'Improved free chlorine amperometric sensor chip for drinking water applications', Anal. Chim. Acta, vol. 554(1-2), pp. 98-104, 2005 https://doi.org/10.1016/j.aca.2005.08.032
- G. Sun, S. Liu, K. Hua, X. Lv, L. Huang, and Y. Wang, 'Electrochemical chlorine sensor with multiwalled carbon nanotubes as electrocatalysts', Electrochemistry Communications, vol. 9, pp. 2436-2440, 2007 https://doi.org/10.1016/j.elecom.2007.07.015
- R. Bauer and C.O. Rupe, 'Use of syringaldazine in a photometric method for estimating 'free' chlorine in water', Analytical Chemistry, vol. 43, pp. 421-425, 1971 https://doi.org/10.1021/ac60298a003
- W.J. Cooper, C.A. Sorber, and E.P. Meier, 'A rapid specific free available chlorine test with syringaldazine (FACTS)', J. American Water Works Association, vol. 67, pp. 34-39, 1975 https://doi.org/10.1002/j.1551-8833.1975.tb02150.x
- W.J. Cooper, N.M. Roscher, and R.A. Slifer, 'Free available chlorine by DPD-colorimetric, DPD-steadifac (clorimetric) and FACTS procedures', J. American Water Works Association, vol. 74, pp. 362-373, 1982 https://doi.org/10.1002/j.1551-8833.1982.tb04942.x
- R.C. Engstrom, 'Electrochemical pretreatment of glassy carbon electrodes', Analytical Chemistry, vol. 54, pp. 2310-2314, 1982 https://doi.org/10.1021/ac00250a038
- R.C. Engstrom, and V.A. Strasser, 'Characterization of electrochemically pretreated glassy carbon electrodes', Analytical Chemistry, vol. 56, pp. 136-141, 1984 https://doi.org/10.1021/ac00266a005
- D.C. Thornton, K.T. Corby, v.s. Spendal, A. Jordan, A. J. Robbat, D.J. Rutstrom, M. Gross, and GRitzler, 'Pretreatment and validation procedure for glassy carbon voltammetric Indicator electrode', Analytical Chemistry, vol. 57, pp. 150-155
- B.W. Cho, C.S. Kim, H.I. Seo, and B.K. Sohn, 'Fabrication and characteristics of FET Type semiconductor urea and glucose sensor employing photolithography techniques', J. Korean Sensors Society, vol. 1, no. 1, pp. 1-6
- B.W. Cho, W.D. Jang, C.S. Kim, H.I. Seo, and B.K. Sohn, 'The improvement of sensing performance of ISFET glucose and sucrose sensors by using platinum electrode and photo-crosslinkable polymers', J. Korean Sensors Society, vol. 4, no. 4, pp. 1-6
Cited by
- Alizarin Red S modified electrochemical sensors for the detection of aluminum ion vol.19, pp.6, 2010, https://doi.org/10.5369/JSST.2010.19.6.421
- Development of Disposable Enzyme-linked Immunosensor Strip Platform vol.20, pp.6, 2011, https://doi.org/10.5369/JSST.2011.20.6.400
- Disposable Electrochemical Immunosensors for the Detection of Herbicide vol.20, pp.1, 2011, https://doi.org/10.5369/JSST.2011.20.1.35