Disposable in-field electrochemical potable sensor system for free available chlorine (FAC) detection

  • Chang, Seung-Cheol (Center for Innovative Bio-Physio Sensor Technology, Pusan National University) ;
  • Park, Deog-Su (Center for Innovative Bio-Physio Sensor Technology, Pusan National University)
  • Published : 2007.11.30

Abstract

The work described in this study concerns the development of a disposable amperometric sensor for the electrochemical detection of a well-known aqueous pollutant, free available chlorine (FAC). The FAC sensor developed used screen printed carbon electrodes (SPCEs) coupled with immobilised syringaldazine, commonly used as an indicator in photometric FAC detection, which was directly immobilised on the surface of SPCEs using a photopolymer PVA-SbQ. To enable in-field analysis of FAC, a prototype hand-held electrochemical analyzer has been developed to withstand the environment with its rugged design and environmentally sealed connections; it operates from two PP3 (9 volt) batteries and is comparable in accuracy and sensitivity to commercial bench top systems. The sensitivity of the FAC sensor developed was $3.5{\;}nA{\mu}M^{-1}cm^{-2}$ and the detection limit for FAC was found to be $2.0{\;}{\mu}M$.

Keywords

References

  1. V.L. Snoeyink and D. Jenkins, (eds.), Water Chemistry, John Wiley and Sons, Inc, New York, 1980
  2. J.R. Kirk and S.K. Mitchell In: R.L. Jolley, W.A. Brungs, and R.B. Cunnning, Editors, Risks and Benefits Associated with Chlorine in the Food Industry, in Water Chlorination: Environmental Impact and Health Effects, vol. 3, Ann Arbor Science, Ann Arbor, 1980
  3. APHA, American Public Health Association Standard Method 6420, Standard methods for the examination of water and wastewater, 20th ed., APHA, Washington, 1999
  4. H. Kim, J. Shim, and S. Lee, 'Formation of disinfection by-products in chlorinated swinnning pool water', Chemosphere, vol. 46, no. 1, pp. 123-130, 2002 https://doi.org/10.1016/S0045-6535(00)00581-6
  5. K. Howard and T.J.J. Inglis, 'The effect of free chlorine on Burkholderia pseudomallei in potable water', Water Res, vol. 37, no. 18, pp. 4425-4432, 2003 https://doi.org/10.1016/S0043-1354(03)00440-8
  6. G.C. White, Handbook of Chlorination, 2nd ed., Van Nostrand Reinhold Co. Inc., New York, 1986
  7. A. Griset, M. Archenault, P. Lacombe, and G. Mondin, 'Integrated chlorine sensor for drinking water distribution security system', Analyst, vol. 22, pp. M13-M15, 1994
  8. B. Saad, W.T. Wai, S. Jab, W.S.W. Ngah, M.I. Saleh, and J.M. Slater, 'Development of flow injection spectrophotometric methods for the determination of free available chlorine and total available chlorine: comparative study', Anal. Chim. Acta, vol. 537(1-2), pp. 197-206, 2005 https://doi.org/10.1016/j.aca.2005.01.055
  9. F. Javier Del Campo, O. Ordeig, and F. Javier Munoz, 'Improved free chlorine amperometric sensor chip for drinking water applications', Anal. Chim. Acta, vol. 554(1-2), pp. 98-104, 2005 https://doi.org/10.1016/j.aca.2005.08.032
  10. G. Sun, S. Liu, K. Hua, X. Lv, L. Huang, and Y. Wang, 'Electrochemical chlorine sensor with multiwalled carbon nanotubes as electrocatalysts', Electrochemistry Communications, vol. 9, pp. 2436-2440, 2007 https://doi.org/10.1016/j.elecom.2007.07.015
  11. R. Bauer and C.O. Rupe, 'Use of syringaldazine in a photometric method for estimating 'free' chlorine in water', Analytical Chemistry, vol. 43, pp. 421-425, 1971 https://doi.org/10.1021/ac60298a003
  12. W.J. Cooper, C.A. Sorber, and E.P. Meier, 'A rapid specific free available chlorine test with syringaldazine (FACTS)', J. American Water Works Association, vol. 67, pp. 34-39, 1975 https://doi.org/10.1002/j.1551-8833.1975.tb02150.x
  13. W.J. Cooper, N.M. Roscher, and R.A. Slifer, 'Free available chlorine by DPD-colorimetric, DPD-steadifac (clorimetric) and FACTS procedures', J. American Water Works Association, vol. 74, pp. 362-373, 1982 https://doi.org/10.1002/j.1551-8833.1982.tb04942.x
  14. R.C. Engstrom, 'Electrochemical pretreatment of glassy carbon electrodes', Analytical Chemistry, vol. 54, pp. 2310-2314, 1982 https://doi.org/10.1021/ac00250a038
  15. R.C. Engstrom, and V.A. Strasser, 'Characterization of electrochemically pretreated glassy carbon electrodes', Analytical Chemistry, vol. 56, pp. 136-141, 1984 https://doi.org/10.1021/ac00266a005
  16. D.C. Thornton, K.T. Corby, v.s. Spendal, A. Jordan, A. J. Robbat, D.J. Rutstrom, M. Gross, and GRitzler, 'Pretreatment and validation procedure for glassy carbon voltammetric Indicator electrode', Analytical Chemistry, vol. 57, pp. 150-155
  17. B.W. Cho, C.S. Kim, H.I. Seo, and B.K. Sohn, 'Fabrication and characteristics of FET Type semiconductor urea and glucose sensor employing photolithography techniques', J. Korean Sensors Society, vol. 1, no. 1, pp. 1-6
  18. B.W. Cho, W.D. Jang, C.S. Kim, H.I. Seo, and B.K. Sohn, 'The improvement of sensing performance of ISFET glucose and sucrose sensors by using platinum electrode and photo-crosslinkable polymers', J. Korean Sensors Society, vol. 4, no. 4, pp. 1-6

Cited by

  1. Alizarin Red S modified electrochemical sensors for the detection of aluminum ion vol.19, pp.6, 2010, https://doi.org/10.5369/JSST.2010.19.6.421
  2. Development of Disposable Enzyme-linked Immunosensor Strip Platform vol.20, pp.6, 2011, https://doi.org/10.5369/JSST.2011.20.6.400
  3. Disposable Electrochemical Immunosensors for the Detection of Herbicide vol.20, pp.1, 2011, https://doi.org/10.5369/JSST.2011.20.1.35