Seismic Response Control of a Building Structure Using Toggle-Brace System with an MR Damper

MR감쇠기를 장착한 토글가새시스템을 이용한 건축구조물의 지진응답제어

  • Published : 2006.09.01

Abstract

In this paper, the performance of a toggle brace-MR damper system is evaluated for the control of the structure excited by earthquake load and the non-linearity of the toggle system is investigated. Considering that the control force of MR damper described by Bingham model is a function of velocity, velocity amplification factor by the toggle brace system is calculated and the effect of toggle configuration on the amplification factor is also evaluated. Numerical results show that the control performance can be largely enhanced using toggle brace system especially for the case that the MR damper installed with conventional brace system such as Chevron and diagonal cannot provide enough control force under severe earthquake load.

본 연구에서는, 지진하중에 의해 구조물에 발생하는 진동을 제어하기 위하여 토글 시스템의 비선형성을 연구하고, 자기유변유체(MR) 감쇠기를 장착한 토글 가새시스템의 성능을 평가하였다. Bingham 모델로 표현되는 MR감쇠기의 제어력이 속도의 함수인 점을 고려하여, 토글 가새시스템에 의한 속도증폭계수를 계산하였고 토글 형태에 대한 증폭계수효과를 평가하였다. 특히 강한 지진하중에서 쉐브론과 대각가새 등의 전형적인 가새시스템에 장착된 MR감쇠기가 충분한 응답감소효과를 제공하지 못하는 경우에, 토글 가새시스템을 사용하여 제어성능을 크게 강화시키는 것을 수치해석 결과를 통하여 확인하였다.

Keywords

References

  1. 강성덕, 홍성목, 황재승, 주석준, 박지훈, 이상현 (1997), 준능동제어장치를 이용한 구조물의 진동제어. 대한건축학회학술발표논문집, 17, pp.413-416
  2. 이상형, 민경원, 이루지, 김중구 (2004), 건축구조물의 지진응답제어를 위한 MR 감쇠기 예비설계절차. 한국지진공학회, 8(5), pp.55-64
  3. 옥승용, 김동석, 박관순, 고현무 (2005). 사장교의 지진응답제어를 위한 준능동 MR 감쇠기의 퍼지제어. 한국지진공학회, 9(6), pp.75-90 https://doi.org/10.5000/EESK.2005.9.6.075
  4. 황재승, 송진규, 강경수, 윤태호 (2003). Toggle 시스템을 이용한 구조물의 진동제어, 한국지진공학회 학술발표대회논문집, 7(1), pp.491-498
  5. Constantinou, M.C., Tsopelas, P., Hammel, W., Sigaher, A.N. (2001). Toggle-Brace-Damper seismic energy dissipation system, Journal of Structural Engineering ASCE, 127, pp.105-112 https://doi.org/10.1061/(ASCE)0733-9445(2001)127:2(105)
  6. Dyke, S. J., Spencer Jr. B. F., Sain M. K., Carlson J. D. (1996). Modeling and control of magnetorheological dampers for seismic response reduction, Smart Materials and Structures, 5. pp.565-575 https://doi.org/10.1088/0964-1726/5/5/006
  7. Gluck, J., Ribakov, Y. (2002). Active viscous damping system with amplifying braces for control of MDOF structures. Earthquake Engineering and Structural Dynamics, 31. pp.1735-1751 https://doi.org/10.1002/eqe.202
  8. Housner, G.W., Bergman, L.A., Caughey, T.K., Chassiakos, A.G., Claus, R.O., Masri, S.F., Skelton, R.E., Soong, T.T., Spencer, B.F.Jr., Yao, J.T.P. (1997), Special issue structural control: past, present, and future, Journal of Engineering Mechanics, 123, pp.897-971 https://doi.org/10.1061/(ASCE)0733-9399(1997)123:9(897)
  9. Meirovitch L. (1990), Dynamics and Control of Structures, John Wiley & Sons, USA, p.425
  10. Yang G. (2001), Large Scale Magnetorheological Fluid Damper for Vibration Mitigation: Modeling, Testing and Control. Ph.D thesis, University of Notre Dame, Indiana, p.259