Anaerobic Digestion Fish Offal(I): Effect of Reactor Configuration and Sludge Bed Fluidization on Start-up of Digester

어류 폐기물의 혐기성소화 처리(I): 반응조 형상 및 슬러지층 유동화가 소화조 Start-up에 미치는 영향

  • Jeong Byung-Gon (School of Civil & Environmental Engineering, Kunsan National University) ;
  • Kim Byung-Hyo (School of Civil & Environmental Engineering, Kunsan National University)
  • 정병곤 (군산대학교 토목환경공학부) ;
  • 김병효 (군산대학교 토목환경공학부)
  • Published : 2006.05.01

Abstract

Effect of organic loading rate on digester performance was evaluated under the conditions of same surface area/reactor volume ratio and different reactor diameter. At the low loading rate of $0.4\;kg\;COD/m^3{\cdot}d$, high rate of organic removal could be obtained regardless of reactor diameter. It can be estimated that reactor configuration can not affect reactor performance at the low loading rate. However, different performance depending on reactor diameter was observed at the organic loading rate of $6\;kg\;COD/m^3{\cdot}d$. That is, volatile acid accumulation and low COD removal efficiency was observed in reactor having 6.4 cm diameter, while volatile acid was not accumulated at all and high COD removal efficiency was observed in reactor having 3 cm diameter. Such a difference of reactor performance depending on reactor diameter can be explained that sludge bed can be fluidized by evolved gas bubble in narrow reactor while sludge bed can not be fluidized by evolved gas bubble only in wide reactor. At a high organic loading rate of $20\;kg\;COD/m^3{\cdot}d$, it can be judged that there is no relation between reactor configuration and reactor performance because all reactors showed very low COD removal efficiencies regardless of reactor diameter. Sludge bed fluidization is one of the most important factors in achieving efficient start-up of anaerobic digester. Narrow and tall type reactor is favorable condition for making sludge bed fluidization at a constant surface area/reactor volume ratio. Thus, it can be judged that reactor configuration and sludge bed fluidization have great influence to reactor performance.

혐기성 소화조의 단면적/용량 비를 일정하게 한 상태에서 반응조 직경만을 달리한 반응조에 유기물 부하율에 따른 소화조 운전효율을 평가하였다. $0.4\;kg\;COD/m^3{\cdot}d$의 낮은 유기물 부하율에서는 반응조 직경에 관계없이 높은 처리 효율을 나타내어 반응조 형상에 따른 처리효율 차이는 없었다. $6\;kg\;COD/m^3{\cdot}d$의 유기물 부하율에서는 반응조 직경에 따라 전혀 다른 처리효율이 관측되었다. 즉, 직경 6.4 cm 반응조에서는 휘발성산의 축적과 낮은 COD 제거효율이 관측되었으나 직경 3 cm 반응조에서는 높은 COD 제거효율이 관측되었고 휘발성산의 축적도 일어나지 않았다. 이러한 차이가 나타나게 된 이유는 직경이 작은 반응조의 경우에는 생성된 가스의 부상에 의해 슬러지층의 유동화가 원활하게 일어난데 반해 직경이 큰 반응조의 경우에는 그렇지 못한 것이라고 판단된다. $20\;kg\;COD/m^3{\cdot}d$의 높은 유기물 부하율에서는 반응조 직경과는 관계없이 극히 낮은 처리효율을 나타내어 높은 유기물 부하에서는 반응조 형상과 처리효율과는 관계가 없는 것으로 나타났다. 따라서 혐기성 소화조의 효율적인 start-up은 슬러지층의 유동화가 중요한 인자이며 동일 단면적/용량 비에서 반응조 직경이 작을수록 유리한 것으로 나타나 반응조 형상도 반응조 운전효율에 큰 영향을 미치는 것으로 나타났다.

Keywords