Immunosensor for Detection of Escherichia coli O157:H7 Using Imaging Ellipsometry

  • Bae Young-Min (Department of Chemical and Biomolecular Engineering, Sogang University) ;
  • Park Kwang-Won (Department of Chemical and Biomolecular Engineering, Sogang University) ;
  • Oh Byung-Keun (Department of Chemical and Biomolecular Engineering, Sogang University) ;
  • Choi Jeong-Woo (Department of Chemical and Biomolecular Engineering, Sogang University)
  • 발행 : 2006.08.01

초록

Imaging ellipsometry (IE) for detection of binding of Escherichia coli O157:H7 (E. coli O157:H7) to an immunosensor is reported. A protein G layer, chemically bound to a self-assembled layer of 11-mercaptoundecanoic acid (11-MUA), was adopted for immobilization of monoclonal antibody against E. coli O157:H7 (Mab). The immobilization of antibody was investigated using surface plasmon resonance. To fabricate antibody spots on a gold surface, protein G solution was spotted onto the gold surface modified with an 11-MUA layer, followed by immobilizing Mab on the protein G spot. Ellipsometric images of the protein G spot, the Mab spot, and Mab spots with binding of E. coli O157:H7 in various concentrations were acquired using the IE system. The change of mean optical intensity of the Mab spots in the ellipsometric images indicated that the lowest detection limit was $10^3$CFU/ml for E. coli O157:H7. Thus, IE can be applied to an immunosensor for detection of E. coli O157:H7 as a detection method with the advantages of allowing label-free detection, high sensitivity, and operational simplicity.

키워드

참고문헌

  1. Arwin, H., S. Welin-Klintstrom, and R. Jansson. 1993. Off-null ellipsometry revisited: Basic considerations for measuring surface concentrations at solid/liquid interfaces. J. Colloid Interface Sci. 156: 377-382 https://doi.org/10.1006/jcis.1993.1125
  2. Bae, Y. M., B.-K. Oh, W. Lee, W. H. Lee, and J.-W Choi. 2003. Immunosensor for detection of Legionella pneumophila based on imaging ellipsometry. Mat. Sci. Eng. C 24: 6164
  3. Brecht, A. and G. Gauglitz. 1995. Optical probes and transducers. Biosens. Bioelectron. 10: 923-936 https://doi.org/10.1016/0956-5663(95)99230-I
  4. De Feijter, J. A., J. Benjamins, and F. A. Veer. 1978. Ellipsometry as a tool to study the adsorption behavior of synthetic and biopolymers at the air-water interface. Biopolymers 17: 1759-1772 https://doi.org/10.1002/bip.1978.360170711
  5. Harke, M., R. Teppner, O. Schulz, H. Motschmann, and H. Orendi. 1997. Description of a single modular optical setup for ellipsometry, surface plasmons, waveguide modes, and their corresponding imaging techniques including Brewster angle microscopy. Rev. Sci. Instrum. 68: 3130-3134 https://doi.org/10.1063/1.1148256
  6. Jin, G., P. Tengvall, I. Lundstrom, and H. Arwin. 1995. A biosensor concept based on imaging ellipsometry for visualization of biomolecular interactions. Anal. Biochem. 232: 69-72 https://doi.org/10.1006/abio.1995.9959
  7. Oh, B.-K., Y.-K. Kim, Y. M. Bae, W.-H. Lee, and J.- W. Choi. 2002. Detection of Escherichia coli O157:H7 using immunosensor based on surface plasmon resonance. J. Microbiol. Biotechnol. 12: 780-786
  8. Oh, B.-K., W. Lee, Y. M. Bae, W. H. Lee, and J.-W. Choi. 2003. Surface plasmon resonance immunosensor for detection of Legionella pneumophila. Biotechnol. Bioprocess. Eng. 8: 112-116 https://doi.org/10.1007/BF02940266
  9. Oh, B.-K., W. Lee, W. H. Lee, and J.-W Choi. 2003. Nano-scale probe fabrication using self-assembly technique and application to detection of Escherichia coli O157:H7. Biotechnol. Bioprocess. Eng. 8: 227-232 https://doi.org/10.1007/BF02942270
  10. Rotermund, H. H., G. Haas, R. U. Franz, R. M. Tromp, and G. Ertl. 1995. Imaging pattern formation in surface reactions from ultrahigh vacuum up to atmosphere pressures. Science 270: 608-610 https://doi.org/10.1126/science.270.5236.608
  11. Stelzle, M., G. Weissmuller, and E. Sackmann. 1993. On the application of supported bilayers as receptive layers for biosensors with electrical detection. J. Phys. Chem. 97: 2974-2981 https://doi.org/10.1021/j100114a025