스프링클러 작동특성(作動特性)과 피난평가(避難評價)에 관한 실증적(實證的) 연구(硏究)

An Empirical Study on the Sprinkler Operational Characteristics and Escape Time Estimation

  • 진복권 (인천북부소방서 대응관리과)
  • 발행 : 2006.06.30

초록

The trends in building construction these days are moving towards having better work spaces and greater suitability for the use of information technology. Therefore people can work in a more relaxed delightful and pleasant environment. Accident such as like fire could cause the mass destruction of human beings. This paper aims to evaluate the path of the spread of a fire and the suitability of fire fighting appliances for maximum egress time. General advanced phase of compartment. Aswell, we analyzed and verified the path of the flame in compartment fires. Also we conducted an analysis of the adaptation of sprinkler systems concerned with sprinkler RTI. Moreover those evaluation is made more earlier by the development and use of computer simulation program and rapid progress to apply PBFD (Performance Based Fire Design).

키워드

참고문헌

  1. 김원국, Room Fire Modeling for performance based Fire Protection Design (1999)
  2. 박창복, "건축물의 피난계획", 소방기술자료집(제 5권), 한국소방안전 협회 (2002) : 16-25
  3. 김동일, "성능위주의 방화설계와 플래시오버", 소방기술자료집 제 5권(2002),: 16-17
  4. Quintiere, James G., Principles of fire Behavior, Pre-Publication copy courtesy of Delmar Publishers (1999)
  5. William, G.B., & Pillips, "Computer Simulation for Fire Protection Engineering", SFPE HandBook . 2nd Edition, Quincy : NFPA (1995)
  6. 백승태 외 4, "피난의 적정성 검토에 관한 연구", 소방학회 추계 학술 대회 논문집 (2002) : 375-381
  7. 한국화재보험협회, NFPA101 인명안전코드 (2003)